§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T±a BENTLY133442-01±a¤º³¡²×ºÝªºÂà 3

BENTLY133442-01±a¤º³¡²×ºÝªºÂà

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

BENTLY NEVADA 133442-01 ±a¤º³¡²×ºÝªºÂà³tªí¼Ò¶ôI/O¼Ò¶ô

BENTLY NEVADA 133442-01 ±a¤º³¡²×ºÝªºÂà³tªí¼Ò¶ôI/O¼Ò¶ô

                                                                              ²£«~¸Ô±¡¸ê®Æ¡G

500«Y²Î°t¦³¨âºØÃþ«¬ªºÄ~¹q¾¹¼Ò¶ô¡C²Ä¤@ºØ¬O4³q¹DÄ~¹q¾¹¼Ò¶ô¡C¸Ó¼Ò¶ô¾A¥Î©óµ´¤j¦h¼ÆªººÊ´úÀ³¥Î¡C¥¦§Q¥Î¤@­ÓÄ~¹q¾¹ÅX°Ê¨C±ø³q¹Dªº¥X¡C4³q¹DÄ~¹q¾¹¼Ò¶ô¬O¤@­Ó¥i´£¨Ñ4­ÓÄ~¹q¾¹¿é¥Xªº¥þ°ª¼Ò¶ô¡C¥ô¦ó¼Æ¶qªº4³q¹DÄ~¹q¾¹¼Ò¶ô¡A³£¥i¥H©ñ¸m¦b®Ø¬[±µ¤f¼Ò¶ô¥k°¼ªº¥ô·N¤@­Ó´¡¼Ñ¤º¡C¨C­ÓÄ~¹q¾¹¿é¥X³£¥i§Q¥Î»P(AND)©M©Î(OR)¹Bºâ¾¹½sµ{¡C¨C¤@Ä~¹q¾¹³q¹Dªº³øĵÅX°ÊÅÞ¿è¡A³£¥iÀ³¥Î¨Ó¦Û®Ø¬[¤¤¥ô¦óºÊ´ú¾¹³q¹Dªº³øĵ¿é¤J(ĵ§i©M¦MÀI)¡C³øĵÅX°ÊÅÞ¿èÀ³¥Î®Ø¬[²ÕºA³n¥ó½sµ{¡C³øĵÅX°ÊÅÞ¿è¾¹ªº¤TºØ´¶³qÃþ«¬¬O¥À½uÄ~¹q¾¹¡BÄ~¹q¾¹©M¿W¥ßÄ~¹q¾¹¡A¥À½uÄ~¹q¾¹À³¥Î¤@­Ó³øĵÅX°ÊÅÞ¿è¾¹¡A¹ï®Ø¬[ùتº©Ò¦³³q¹DªºÄµ§i©Î¦MÀI«H¸¹¶i¦æ¡§©Î¡¨¹Bºâ¡A¨ÓÅX°Ê¤@­Ó³æ¿WªºÄ~¹q¾¹¡CÄ~¹q¾¹À³¥Îªº³øĵÅX°ÊÅÞ¿è¾¹¡A¬O¹ïºÊ´ú¾¹¤¤ªº³q¹D¹ï(³q¹Dl©M³q¹D2©Î³q¹D3©M³q¹D4)¤WªºÄµ§i©Î¦MÀI±¡¸¹¶i¦æ¡§©Î¡¨¹Bºâ¡A¨ÓÅX°Ê¤@­ÓÄ~¹q¾¹¡C¿W¥ßÄ~¹q¾¹À³¥Îªº³øĵÅX°ÊÅÞ¿è¾¹¡A¥i¥H¨Ï¨Ó¦Û¤@­Ó³q¹D¤Wªº¨C­Ó³øĵª¬ºA(ĵ§i©Î¦MÀI)¡A¥hÅX°Ê¤@­Ó¿W¥ßªºÄ~¹q¾¹¡C

4 ³q¹DÄ~¹q¾¹¼Ò¶ô¬O¤@­Ó¥þ°ª«×ªº¼Ò¶ô¡A¥¦¥i´£¨Ñ¥|­ÓÄ~¹q¾¹ªº¿é¥X¶q¡C¥ô¦ó¼Æ¶qªº4 ³q¹DÄ~¹q¾¹¼Ò¶ô¡A³£¥i©ñ¸m¦b®Ø¬[±µ¤f¼Ò¶ô¥kÃ䪺¥ô¤@­Ó¼Ñ¦ìùØ¡C4 ³q¹DÄ~¹q¾¹¼Ò¶ôªº¨C­Ó¿é¥X³£¥i¥H¿W¥ß½sµ{¡A¥H°õ¦æ©Ò»Ý­nªºªí¨MÅÞ¿è¡C

¨C­ÓÀ³¥Î¦b4 ³q¹DÄ~¹q¾¹¼Ò¶ô¤WªºÄ~¹q¾¹¡A³£¨ã¦³¡§³øĵÅX°ÊÅ޿表¡C¸Ó³øĵÅX°ÊÅÞ¿è¥i¥Î¡§»Pªù¡¨©M¡§©Îªù¡¨ÅÞ¿è½sµ{¡A¨Ã¥i§Q¥Î®Ø¬[¤¤ªº¥ô¦óºÊ´ú¾¹³q¹D©Î¥ô¦óºÊ´ú¾¹³q¹Dªº²Õ¦X©Ò´£¨Ñªº³øĵ¿é¤J(ĵ§i©Î¦MÀI)¡C¸Ó³øĵÅX°ÊÅÞ¿èÀ³¥Î®Ø¬[²ÕºA³n¥ó½sµ{¡A¥iº¡¨¬À³¥Î¤¤ªº¯S®í»Ý­n¡C

                         ²£«~­^¤å¸Ô±¡®Æ:

The 500 system comes with two types of relay modules. The first type is a 4-channel relay module. This module is suitable for the vast majority of monitoring applications. It utilizes a relay to drive the output of each channel. The 4-channel relay module is a full height module that can provide 4 relay outputs. Any number of 4-channel relay modules can be placed in any slot on the right side of the frame interface module. Each relay output can be programmed using AND and OR operators. The alarm driving logic of each relay channel can be applied to alarm inputs (warning and danger) from any monitor channel in the framework. Programming of alarm driven logic application framework configuration software. The three common types of alarm driven logic devices are bus relays, relays, and independent relays. Bus relays use an alarm driven logic device to perform an "OR" operation on the warning or danger signals of all channels in the framework to drive a separate relay. The alarm driven logic for relay applications is an OR operation performed on the warning or danger signals on channel pairs (channels 1 and 2 or 3 and 4) in the monitor to drive a relay. The alarm driver logic for independent relay applications can enable each alarm state (warning or danger) from a channel to drive an independent relay.

The 4-channel relay module is a full height module that can provide the output of four relays. Any number of 4-channel relay modules can be placed in any slot on the right side of the frame interface module. Each output of the 4-channel relay module can be independently programmed to execute the required voting logic.

Each relay applied to a 4-channel relay module has an "alarm drive logic". The alarm drive logic can be programmed with "AND" and "OR" logic, and can use the alarm input (warning or danger) provided by any monitor channel or any combination of monitor channels in the frame. The alarm driven logic application framework configuration software programming can meet special needs in applications.

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C

¥»¯S§QPR6424/016-030 CON021PROSOFTMVI56-DFCMR
EMERSONPR6424/010-140 CON021PROSOFTMVI56-ADMNET
EMERSONPR6424/010-110 CON021PROSOFTMVI56-ADM
¥»¯S§QPR6424/010-040 CON021PROSOFTMVI46-MCM
EPROPR6424/010-010-CN CON021PROSOFT5205-DFNT-PDPS
EPROPR6424/010-010 CON021EMERSONKJ4001X1-CA1 12P0623X062
EMERSONPR6424/010-000 CON021EMERSONKJ4001X1-CC1 12P0733X032
EPROPR6424/010-000 CON021EMERSONKJ4001X1-CC1 12P0733X042


Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H