«¬¸¹¡G CV-OPCSAE

«~µP¡GÀN¥§­³º¸

       

                                                       ²£«~¸Ô±¡¸ê®Æ¡G

©Þ¥X©Î­«·s´¡¤JÄ~¹q¾¹¤§«e¡AÃö³¬±±¨î¹q·½¡A¥H¨¾¤î»~¾Þ§@¡I¦pªG¸Õ¹Ï±N¸Ë¸m¦w¸Ë¨ì¤£¤Ç°tªº¥~´ß¤¤¡A¾÷±ñÆ_°Í±Nªý¤î¸Ë¸m§¹¥þ´¡¤J¡C¦b¥H¤U¨BÆJ¤¤¤£­n¥Î¤O¡A§_«h¥i¯à·|³y¦¨·lÃa¡C­n±q¾÷½c¤¤¨ø¤U³æ¤¸¡G1¡C§ì¦í¥k°¼ªº¤¤¤ß¡AµM«á©Ô°Ê»\¤l¡A¥´¶}»\¤l¡A»\¤l±N³ò¶¥ª°¼ªº»ÇÃì±ÛÂà¡C2.¥ÎÁ³µ·¤M¦V¤W«öÀ£Âê­¬¡AªQ¶}¦ì©óÂê¬`¤U¤èªºÂê­¬¡C

³q±`±¡ªp¤U¡A469¸Ë¸m¦b¥X¼t®É¦w¸Ë¦b¥~´ß¤¤¡A¦b±N¥~´ß¦w¸Ë¦b¤ä¼µ­±ªO¤¤¤§«e¡AÀ³±N¨ä©î¤U¡C¤U¤@¸`±N´y­z³æ¤¸ªººM¦^¡C¹Ï2-4¡G³æ469©MÂù469¤Á³Î­±ªO·Ç³Æ¦n­±ªO¤¤ªº¦w¸Ë¤Õ«á¡A±q«e­±±N469¥~´ß·Æ¤J­±ªO¡C¦b«e­±ªO¤W¬I¥[¨c©TªºÀ£¤O¡A¥H½T«O«e¾×ªOºò¶K­±ªOªº«e³¡¡A¦p¤U¹Ï©Ò¥Ü¡A±q¥~´ßªº¨C¤@°¼Ås¦±¤@¹ï©T©w¥Y¦Þ¡]¦Ü¤ô¥­¦ì¸m¡^¡C¾÷½c²{¤w¨c©T¦w¸Ë¡A¥i¥Î©ó­±ªO¥¬½u¡C¦pªG»Ý­nÃB¥~ªº¤ä¼µ¡A¥i¥H­qÁÊSR¥i¿ï¦w¸Ë®M¥ó¡C

                         ²£«~­^¤å¸Ô±¡¸ê®Æ¡G

TURN OFF CONTROL POWER BEFORE DRAWING OUT OR RE-INSERTING THE RELAY TO PREVENT MALOPERATION! If an attempt is made to install a unit into a non-matching case, the mechanical key will prevent full insertion of the unit. Do not apply strong force in the following step or damage may result. To remove the unit from the case: 1. Open the cover by grasping the center of the right side and then pulling the cover, which will rotate about the hinges on the left. 2. Release the locking latch, located below the locking handle, by pressing upward on the latch with the tip of a screwdriver.

Normally the 469 unit is mounted in its case when shipped from the factory, and should be removed before mounting the case in the supporting panel. Unit withdrawal is described in the next section. Figure 2¡V4: SINGLE AND DOUBLE 469 CUTOUT PANELS After the mounting hole in the panel has been prepared, slide the 469 case into the panel from the front. Applying firm pressure on the front to ensure the front bezel fits snugly against the front of the panel, bend out the pair of retaining tabs (to a horizontal position) from each side of the case as shown below. The case is now securely mounted, ready for panel wiring. If additional support is desired, the SR optional mounting kit may be ordered.

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


NEYWELLMU-TLPA02 51304467-100PROSOFTMVI71-ADM
HONEYWELLMU-TLPA02 51309204-125PROSOFTMVI71-AFC
HONEYWELLMU-TPIX12 51304084-100PROSOFTMVI71-MNET
HONEYWELLMU-TSDM02  51303932-277PROSOFTMVI94-ADM
ALLEN-BRADLEY1756-IB16IFABBHESG447398R20 HE666710-318/1 70EA06A-E
ALLEN-BRADLEY1756-IB16ISOEABBHESG447427R1 HE666455-318/25 70EI05A-E
ALLEN-BRADLEY1756-IC16ABBHIEE200072R0002  USB030AE02
ALLEN-BRADLEY1756-IH16IABBHIEE200072R2  USB030AE02 