IC200ALG430LT GE ³q°T¼Ò¥ó
IC200ALG430LT GE ³q°T¼Ò¥ó
IC200ALG430LT GE ³q°T¼Ò¥ó
¥»±±¨î¾¹¤§«OÅ@¸Ë¸m: (1)¨Ó·½¹q¤í¬Û¡C (2)«OÀIµ·Â_½uÀ˪¾¡C (3)¥»±±¨î¾¹´²¼ö¤ù¶W·Å«OÅ@¡C (4)²§±`¿é¥X±µÂI¡A´£¨Ñ»·ºÝºÊ±±¨Ï¥Î¡A±µÂI®e¶q240VAC/5A¡C
4.¥»±±¨î¾¹¨ã¦³CE°ê»Ú»{ÃÒ¤§¼Ð·Ç¡C
5.¨ã¦³RST¦U¬Û«OÀIµ·Â_¸ô«ü¥Ü¿O¡A¨Ã´£¨Ñ²§±`¿é¥X±µÂI¡A¥i°µ«Y²Îºò«æ±±¨î¤§¥Î¡C
6.§N«o·®°°Ê§@¨ã¦³·Å«×±±¨î¡A·í´²¼ö¤ù·Å«×55«×®É¤u§@¡A45«×®É°±¤î¡A¥i´£°ª·®°¹Ø©R2-3¿¡C
7.¨Ï¥Î§C¿ÓªiSCR¹q¤O½Õ¾ã¾¹¡A¥i¥H´î¤Ö¨Ï¥Î¥D°Ê¦¡Âoªi¾¹©Î³Q°Ê¦¡Âoªi¾¹ªº¦w°ö¼Æ¡A¥D°Ê¦¡Âoªi¾¹¥«»ù¤j¬ù1¦w°ö5000-8000¤¸¤£µ¥¡A¨Ï¥Î§C¿ÓªiSCR¹q¤O½Õ¾ã¾¹1¦w°ö¥un¥D°Ê¦¡Âoªi¾¹ªº1/20»ù®æ¡C1.¥D¹q·½¹qÀ£: AC 220V 380-480V ¡Ó10%
2.»²§U¹qÀ£: AC 220V¡Ó15% 50/60Hz
3.ÃB©w¹q¬y: 25A 35A 50A 60A 80A 100A 125A 160A 180A 200A 225A 250A 300A 350A 400A 600A 750A
4.¤u§@ÀW²v: 47-63Hz
5.¿é¥X¤è¦¡: ¤ñ¨Ò¦¡¿é¥X
6.¿é¤J±±¨î°T¸¹: 4-20mA, 0-5V, 1-5V, 0-10V, 2-10V.
7.¿é¥X¹qÀ£½d³ò: 0-100%
8.¨Ï¥ÎÀô¹Ò: -10«×-50«× Àã«× 90%RH¥H¤U
9.µ´½tªý§Ü: 20 M£[ ¥H¤W(¹q·½»P¥~´ß¶¡)¡B 20 M£[ ¥H¤W(¿é¤J«H¸¹»P¥~´ß¶¡)
10.@À£±j«×: ¹q·½»P¥~´ß¶¡ 2500VAC/1¤ÀÄÁ¡B¹q·½»P¿é¤J«H¸¹ 1000VAC/1¤ÀÄÁ
1. ¥»±±¨î¾¹¤§«OÅ@¸Ë¸m: 1.¨Ó·½¹q¤í¬Û¡C 2.«OÀIµ·Â_½uÀ˪¾¡C 3.¥»±±¨î¾¹´²¼ö¤ù¶W·Å«OÅ@¡C 4.²§±`¿é¥X±µÂI¡A´£¨Ñ»·ºÝºÊ±±¨Ï¥Î¡A±µÂI®e¶q240VAC/5A¡C
2. ¥»±±¨î¾¹¨ã¦³CE°ê»Ú»{ÃÒ¤§¼Ð·Ç¡C
3. ¨ã¦³RST¦U¬Û«OÀIµ·Â_¸ô«ü¥Ü¿O¡A¨Ã´£¨Ñ²§±`¿é¥X±µÂI¡A¥i°µ«Y²Îºò«æ±±¨î¤§¥Î¡C
4. §N«o·®°°Ê§@¨ã¦³·Å«×±±¨î¡A·í´²¼ö¤ù·Å«×55«×®É¤u§@¡A45«×®É°±¤î¡A¥i´£°ª·®°¹Ø©R2-3¿¡C
5. À³¥Î©ót¸ü: IR¿OºÞ¡A¥Û^¿OºÞ¡A¤Gª¿¤Æ໡A¥[¼ö¾¹¡C ¨Ï¥Î¨î¾c¾÷±ñ¡A¶ì½¦§j²~¾÷±ñ¡A¶ì½¦À£¥X¾÷±ñ¡A¯uªÅ»]Áá¾÷¡A¯uªÅÂqÁá¾÷¡A¼ö³B²zÄl¡A¹q¼öº²Äl¡A¹q¼öÁçÄl¡Aº£¥]½u¾÷±ñ¡A©â¯½¾÷±ñ¡A¯¼Â´¾÷±ñ¡AùÚ·ÅùÚÀã«Y²Î¡C
6. ¹L¸ü«OÅ@: °{Ã{1¤U¡C
¨Ó·½¹q¤í¬Û«OÅ@: °{Ã{2¤U¡C
¤T¬Û¤£¥¿Å«OÅ@: °{Ã{3¤U¡C
¥»Åé¹L·Å«OÅ@: °{Ã{4¤U¡C
t¸üÂ_½u«OÅ@: °{Ã{5¤U¡C
7. ³]©w°ª¹q¬y¨î¡AÅý¨Ï¥ÎªÌ§ó¦h¤¸¤Æ¿ï¾Ü1.¥D¹q·½¹qÀ£: AC 220V 380-480V ¡Ó10%
2.»²§U¹qÀ£: AC 220V¡Ó15% 50/60Hz
3.ÃB©w¹q¬y: 25A-750A
4.¤u§@ÀW²v: 47-63Hz
5.¿é¥X¤è¦¡: ¬Û¦ì±±¨î¿é¥X
6.¬Û¦ì¿é¤J±±¨î°T¸¹: 4-20mA, 0-5V, 1-5V, 0-10V, 2-10V¡C
7.¿é¥X¹qÀ£½d³ò: 0-100%
8.¨Ï¥ÎÀô¹Ò: -10«×-50«× Àã«× 90%RH¥H¤U
ESD±±¨î«Y²Î:
Triconex¤½¥qªºTRICON«Y²Î¡F
Honeywell¤½¥qªºFSC«Y²Î¡F
HIMA¤½¥qªºH41q©MH51q«Y²Î¡F
GE¤½¥qªºS90-70 GMR«Y²Î¡FGE SafetyNet¡F
Siemens¤½¥qªºS7-400FH«Y²Î¡F
Moore¤½¥qªºQUADLOG«Y²Î¡F
Woodward¤½¥qªºMicro Net TMR«Y²Î¡F
ICS Triplex¤½¥qªºRegent«Y²Î¡BTrusted«Y²Î¡F
®ý¦¿¤¤±±¶°¦¨ªºGE90-70 GMR«Y²Îµ¥µ¥¡C
4 169 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
5 PQM 2 Power Quality Meter ¬Ù¿ú¼ö½u¡G0592-5361112
6 239 Motor Protection Relay ¬Ù¿ú¼ö½u¡G0592-5361112
7 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
8 469 P5-HI-A20 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
9 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
10 SR489 Generator Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
11 SR750 Feeder Management Relay¬Ù¿ú¼ö½u¡G0592-5361112
12 SR469 Motor Management Relay¬Ù¿ú¼ö½u¡G0592-5361112
13 SR750 Feeder Management Relay¬Ù¿ú¼ö½u¡G0592-5361112
14 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
15 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
16 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
17 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
18 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
19 PQM Mod 504 Detached faceplate ¬Ù¿ú¼ö½u¡G0592-5361112
20 SR489 Generator Management Relay Detached faceplate ¬Ù¿ú¼ö½u¡G0592-5361112
21 SR750 Feeder Management Relay Damaged faceplate ¬Ù¿ú¼ö½u¡G0592-5361112
22 SR489 Generator Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
23 SR489 Generator Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
24 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
25 SR489 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
26 SR489 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
27 SR469 Motor Management Relay Cracked front top ¬Ù¿ú¼ö½u¡G0592-5361112
28 SR489 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
29 SR469 Motor Management Relay Faceplate missing ¬Ù¿ú¼ö½u¡G0592-5361112
30 SR469 Motor Management Relay Faceplate missing ¬Ù¿ú¼ö½u¡G0592-5361112
31 SR469 Motor Management Relay Faceplate ¬Ù¿ú¼ö½u¡G0592-5361112
32 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
33 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
34 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
35 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
36 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
37 SR469 Motor Management Relay Handlebar + front top part cracked ¬Ù¿ú¼ö½u¡G0592-5361112
38 SR489 Generator Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
39 269 Plus Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
40 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
41 SR469 Motor Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
42 SR469 Motor Management Relay top part damaged ¬Ù¿ú¼ö½u¡G0592-5361112
43 269 Plus Motor Management Relay slight crack ¬Ù¿ú¼ö½u¡G0592-5361112
44 SR750 Feeder Management Relay ¬Ù¿ú¼ö½u¡G0592-5361112
45 PQM 2 Power Quality Meter Missing backplate ¬Ù¿ú¼ö½u¡G0592-5361112
46 SR750 Feeder Management Relay Handlebar loose ¬Ù¿ú¼ö½u¡G0592-5361112