HV-1000Åã·Lµw«×­p

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§
 

ªZº~®æµÜ²öÀË´ú³]³Æ¦³­­¤½¥q  

¹q¸Ü¡G13545068882¡F027-86619889

¶Ç¯u¡G027-86619889  

ºô§}¡Gwww.glmgs.com

http://www.glmgs.com/prodxx.asp?id=608

¤@¡B²£«~²¤¶
    HV-1000«¬Åã·Lµw«×­p¬O°ò¥»«¬ªºÅã·Lµw«×­p¡A¸Ó¾÷±Ä¥ÎLCDÅã¥Ü«Ì¡A³q¹L¾Þ§@­±ªO¥i¹ïµw«×¼Ð¤ØHV©ÎHK¦UÀɸÕÅç¤O«O²ü®É¶¡¶i¦æ¿ï¾Ü¡A¥ú·½«G«×¥i§@µL¯Å½Õ¸`¡C¾Þ§@®É¡A¥i±N¥ØÃè´ú±oªºD1,D2­Èª½±µ¿é¤J«á¡Aµw«×­È§Y¦bLCDÅã¥Ü«Ì¤Wª½±µÅã¥Ü¡C¾A¥Î½d³ò¡G¼ö³B²z¡BºÒ¤Æ¡B²f¤õµw¤Æ¼h¡Aªí­±Âмh¡A¿û¡A¦³¦âª÷ÄÝ©M·L¤p¤ÎÁ¡§Î¹s¥óµ¥¡C
¤G¡B§Þ³N«ü¼Ð
    ¡¹¸ÕÅç¤O¡G10gf (0.098N)¡B25gf (0.245N)¡B50gf (0.49N)¡B100gf (0.98N )¡B200gf (1.96N)¡B300gf (2.94N)¡B500gf (4.9N)¡B1000gf (9.8N)
    ¡¹¤p´ú¶q³æ¦ì¡G0.5£gm
    ¡¹Á`©ñ¤j­¿¼Æ¡G100X¡]Æ[¹î ¡^400X¡]´ú¶q¡^
    ¡¹¥[²ü¤è¦¡¡G¦Û°Ê¡]¥[²ü¡B«O²ü¡B¨ø²ü¡^
    ¡¹»ö¾¹¤Ø¤o¡]ªø¡Ñ¼e¡Ñ°ª¡^¡G405¡Ñ290¡Ñ480mm 
    ¡¹»ö¾¹­«¶q¡G25kg
    ¡¹¸Õ¥ó¤j°ª«×¡G65mm
    ¡¹¹q·½¡GAC220V¡Ó5%¡A50~60Hz
    ¡¹°õ¦æ¼Ð·Ç¡GGB/T4340.2°ê®a¼Ð·Ç¡FJJG151ÀË©w³Wµ{
    ¡¹X-Y¸Õ»O¡G¤Ø¤o¡G100¡Ñ100 mm¡F¤j²¾°Ê¡G25¡Ñ25mm
    ¡¹¼Ð·Ç°t¥ó ªþ¥ó¡G ª«Ãè40x¡B10x¡A·L¤óÀ£ÀY¡A´ú¶q¥ØÃè10x¡A¼Ð·Çµw«×¶ô¡]2¡^¡AÁ¡§Î¸Õ»O¡B¶ê¬WÅé¸Õ»O¡B¥­¤f¸Õ»O¡A¤ô¥­»ö¡A¹q·½½u¡A»²§U¤u¨ãµ¥


One, product introduction
HV-1000 micro-hardness instrument is the basic type of the microhardness, the machine adopts LCD display screen, through the operating panel can be on the scale of hardness HV or HK stall test to secure the load time of choice, the brightness of the light source can be steplessly adjusted. When in operation, the eyepiece measured D1, D2 directly after input, hardness value to be displayed on the LCD screen. Scope of application: heat treatment, carbide, hardening, surface coating, steel, nonferrous metal and micro and thin shaped components.
Two, technical indicators
¡¹test: 10GF ( 0.098N ), 25gf ( 0.245N ), 50gf ( 0.49N ), 100gf ( 0.98N ), 200gf ( 1.96N ), 300gf ( 2.94N ), 500gf ( 4.9N ), 1000gf ( 9.8N )
The smallest unit of measurement: 0.5 £g M
Of the total magnification: 100X ( observation) 400X ( measurement )
¡¹loading mode: automatic ( loading, and loading, unloading )
¡¹instrument dimensions (L x W x H): 405 x 290 x 480mm
¡¹the weight of the instrument: 25kg
¡¹specimen maximum height: 65mm
¡¹power: AC220V ¡Ó 5%, 50~60Hz
¡¹executive standard: GB/T4340.2 JJG151 national standards; verification regulation
¡¹ X-Y testing table: size: 100¡Ñ 100 mm; the largest mobile: 25 ¡Ñ 25mm
¡¹standard accessories: Objective 40x, 10x, Vickers indenter, measuring eyepiece 10x, standard hardness block ( 2), a thin bench, cylinder test station, flat oral stage, level meter, power line, auxiliary tools

Áp«Y¤è¦¡
  • Áp«Y¤H¡G ®}®ü¬W ¥ý¥Í
  • ¾¦ì¡G ¾P°â¸g²z
  • ¶Ç ¯u¡G 027-86619889
  • ¹q¸Ü¡G 027-86619996
  • ¤â¾÷¡G 13545068882
  • ¦a §}¡G ´ò¥_¬Ù ªZº~¥« ®}ªF¤jµó51¸¹
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H
  • 01
  • §Ö³tµo¥¬¨DÁÊ«H®§
  • ¤U¤@¨B
  • 03
  • Áp«Ycnal«ÈªA¡G
  • ­P¹q¡G 0371-63388900
    °¨¤W±Ò°Ê±zªº§Ö³t±ÄÁʳq¹D¡I
  • 04
  • ¬ÛÃö²£«~