GKRA2K2A2¹qºÏ»Ö¥iij»ù
GKRA2K2A2¹qºÏ»Ö¥iij»ù
GKRA2K2A2¹qºÏ»Ö¥iij»ù
GKRA2K2A2¹qºÏ»Ö²£«~¯S©Ê
GKRA2K2A2¹qºÏ»Ö¤u§@ì²z
GKRA2K2A2¹qºÏ»Ö§Þ³N³W®æ
GKRA2K2A2¹qºÏ»ÖÀ³¥Î»â°ì
GKRA2K2A2 ¹qºÏ»Ö·§z
GKRA2K2A2 ¹qºÏ»Ö¬O¤@ºØ¯S©w«¬¸¹ªº¤u·~±±¨î³]³Æ¡A¥¦ÄÝ©ó¹qºÏ»Öªº¤@ºØ¡A¥Dn¥Î©ó¦Û°Ê¤Æ«Y²Î¤¤±±¨î¬yÅ骺¬y°Ê¡C¹qºÏ»Ö³q¹L¹qºÏ¤O¨Ó±±¨î»Öªùªº¶}±Ò©MÃö³¬¡A±q¦Ó¹ê²{¹ï¬yÅ骺ºë¡P±±¨î¡C³oºØÃþ«¬ªº¹qºÏ»Ö¥i¯à¦b¦hºØ¤u·~»â°ì¤¤±o¨ìÀ³¥Î¡A¨Ò¦p¨î³y·~¡B¥b¾ÉÅé¤u·~¡B¥Ûªo¤Æ¤uµ¥¡C
GKRA2K2A2 ¹qºÏ»Öªº¤u§@ì²z
GKRA2K2A2 ¹qºÏ»Öªº¤u§@ì²z»P¨ä¥L¹qºÏ»ÖÃþ¦ü¡A¥¦¤º³¡¦³¤@Ó±K³¬ªºµÄÅé¡AµÄÅ骺¤£¦P¦ì¸m¶}¦³³q¤Õ¡A¨CÓ³q¤Õ³£³q¦V¤£¦PªºªoºÞ¡C¦bµÄÅ餤¶¡¬O»ÖÅé¡A¨â°¼¬O¨â¶ô¹qºÏÅK¡C·í¹qºÏÅKªº½u°é³q¹q®É¡A·|²£¥Í¹qºÏ§l¤O¡A§l¤Þ»ÖÅé²¾°Ê¨ì¬ÛÀ³ªº¦ì¸m¡A±q¦Ó¥´¶}©ÎÃö³¬³q¦V¤£¦PªoºÞªº¤Õ¡C³o¼Ë¡A³q¹L±±¨î¹qºÏÅKªº¹q¬y¡A´N¥i¥H±±¨î¬yÅ骺¬y¦V©M¬y¶q¡C
GKRA2K2A2 ¹qºÏ»Öªº¯SÂI
GKRA2K2A2 ¹qºÏ»Öªº¯SÂI¥i¯à¥]¬A¨ä°Ê§@¤è¦¡¡B»Öäµ²ºc©M§÷®Æµ¥¡C¨Ò¦p¡A¥¦¥i¥H¬Oª½°Ê¦¡¡B¤Ï½Ä¦¡©Î¥ý¾É¦¡¤§¤@¡C³o¨Ç¤£¦Pªº°Ê§@¤è¦¡¨M©w¤F¹qºÏ»Ö¦b¤£¦P¤uªp¤Uªº©Ê¯à©M¾A¥Î½d³ò¡C¦¹¥~¡A¹qºÏ»Öªº±K«Ê§÷®Æ¤]·|¼vÅT¨ä@»G»k©Ê©M¨Ï¥Î¹Ø©R¡C
GKRA2K2A2 ¹qºÏ»ÖªºÀ³¥Î³õ´º
GKRA2K2A2 ¹qºÏ»Ö¥i¯àÀ³¥Î©ó»Ýn¡P½T±±¨î¬yÅ骺³õ¦X¡A¤ñ¦p¥b¾ÉÅé¤u·~¤¤ªº®ðÅé±±¨î¡B¨î®ñ¾÷¤¤ªº®ñ®ð¬y¶q½Õ¸`µ¥¡C¦b¥b¾ÉÅé¤u·~¤¤¡A¥Ñ©ó¨Ï¥Îªº®ðÅé¦h¬°¦³¬r©Î¦³»G»k©Ê¡A¦]¦¹¹ï¹qºÏ»Öªºº|²vn¨D«D±`ÄY®æ¡A»Ýn½T«O¨ä¦w¡P©Ê¡C
ª`·N¨Æ¶µ
»Ýnª`·Nªº¬O¡AGKRA2K2A2¨Ã«D¤@Ó¼sªx»{ª¾ªº¼Ð·Ç²£«~«¬¸¹¡A¦Ó¬O¯S©w¼t®a©Î²£«~½uªº¼ÐÃÑ¡C¦]¦¹¡A¦b¿ï¾Ü©M¨Ï¥Î®É¡AÀ³®Ú¾Ú¨ãÅ骺¤uªp©M§Þ³Nn¨D¨Ó½T©w¬O§_¾A¦X¨Ï¥Î¸Ó«¬¸¹ªº¹qºÏ»Ö¡C¦P®É¡A¦Ò¼{¨ì¹qºÏ»Öªº¡P¥þ©Ê©M¥i¾a©Ê¦ÜÃö«n¡A¯S§O¬O¦b¯A¤Î¦³¬r©Î°ªÀ£Àô¹Ò®É¡AÀ³ÄY®æ¿í¦u¬ÛÃöªº¦w¡P¼Ð·Ç©M¾Þ§@³Wµ{¡C
GKRA2K2A2 solenoid valve overview
GKRA2K2A2 solenoid valve is a specific type of industrial control equipment. It is a type of solenoid valve and is mainly used to control the flow of fluids in automation systems. The solenoid valve uses electromagnetic force to control the opening and closing of the valve, thereby achieving precise control of the fluid. This type of solenoid valve may find application in a variety of industrial areas, such as manufacturing, semiconductor industry, petrochemical industry, etc.
Working principle of GKRA2K2A2 solenoid valve
The working principle of the GKRA2K2A2 solenoid valve is similar to that of other solenoid valves. It has a closed cavity inside, with through holes at different positions in the cavity, and each through hole leads to a different oil pipe. In the middle of the cavity is the valve body, with two electromagnets on both sides. When the coil of the electromagnet is energized, it will generate electromagnetic attraction, attracting the valve body to move to the corresponding position, thereby opening or closing the holes leading to different oil pipes. In this way, by controlling the current of the electromagnet, the flow direction and flow rate of the fluid can be controlled.
Features of GKRA2K2A2 solenoid valve
Features of the GKRA2K2A2 solenoid valve may include its mode of operation, disc structure and materials. For example, it can be one of direct-acting, recoil-operated, or pilot-operated. These different action modes determine the performance and application range of the solenoid valve under different working conditions. In addition, the sealing material of the solenoid valve will also affect its corrosion resistance and service life.
Application scenarios of GKRA2K2A2 solenoid valve
GKRA2K2A2 solenoid valve may be used in situations where precise fluid control is required, such as gas control in the semiconductor industry, oxygen flow adjustment in oxygen generators, etc. In the semiconductor industry, since most of the gases used are toxic or corrosive, the leakage rate requirements of solenoid valves are very strict and their safety needs to be ensured.
Things to note
It should be noted that GKRA2K2A2 is not a widely recognized standard product model, but an identification of a specific manufacturer or product line. Therefore, when selecting and using, you should determine whether this type of solenoid valve is suitable for use based on specific working conditions and technical requirements. At the same time, it is crucial to consider the safety and reliability of solenoid valves, especially when toxic or high-pressure environments are involved, and relevant safety standards and operating procedures should be strictly followed.
ABB Board Measuring MODEL: SDCS-IOE-2
1PC30060EA433PA6¼Æ¶q1
MSZE-3-24DC¼Æ¶q2
ABR-1S318B¼Æ¶q2
3BSE022462R1 1
RPBA-01ABBפ«¾÷ÅÜÀW¾¹ACS800
RTAC-01ABBפ«¾÷ÅÜÀW¾¹ACS800
APBU-44CABBפ«¾÷ÅÜÀW¾¹ACS800
RDCU-12CABB`0001788פ«¾÷ÅÜÀW¾¹
6SE7090-0XX84-0AB0 1
6ES7313-6CG04-0AB0 4
6SE7023-8ED61-Z 4
BMXXBP0800 4
MM3-4FXM2
MM3-2FXM2/2TX1
6SE7090-0XX84-0AB0 4
RDUM-01¼Æ¾Ú½uªø«×3M 14
6SL3210-1SE24-5AA0
6SL3120-2TE13-0AA4
6SL3040-1MA00-0AA0
6SL3040-0PA00-0AA1
TWDLCDA24DRF 1
SEWMDX61B0030-5A3-4-0T
SEWDEH11B
SEWDFE32B ¦U2
6ES7954-8LE03-0AA0 1
7MH4980-1AA01 1
6AV2124-0JC01-0AX0 1
6AV7260-5DM20-0XX5 1
6ES7 647-6CE00-0BC0 1
6SL3514-1KE13-5AE0 ¼Æ¶q2
6FX8002-5DN01-1BF0 ¼Æ¶q1
6ES7952-1KY00-0AA0????4Ó
ÅX°Ê¼Ò¶ô 6SL3120-1TE21-8AA3 2 ¥ó
6ES7400-2JA10-0AA0 1
6ES7407-0KA02-0AA0 2
6ES7417-5HT06-0AB0 2
6GK7443-1EX30-0XE0 2
6ES7952-1AP00-0AA0 2
6ES7960-1AA06-0XA0 4
6ES7960-1AA04-5AA0 2
6ES7971-0BA00 4
6ES7307-1BA01-0AA0 1
6ES7331-7NF10-0AB0 2
6ES7332-5HF00-0AB0 2
6ES7392-1AM00-0AA0 6
6ES7870-1AA01-0YA1 1
6ES7341-1CH02-0AE0 1
L&L·ç¨åµÜ¯ÇªL¼w
¦ãÀq¥Í ¦øªAÅX°Ê¾¹DST1201P
6SE7036-0EF85-0EA0 1Ó
6SE7032-2FC85-0JA0 1Ó
6ES7 331-7TF01-0AB0 4Ó
6FX8002-2DC10-1BF0 ¼Æ¶q1
FX3G-24MR/ES 1
HESG447271R00021
HESG447440R0001 70BK03C-E2
HESG332204R0001 70PR05B-ES2
HTGZ401553R12
GKWE858300R12101
GKWE857800R1414 + GKWE858200R14141
PNI800 ¼Æ¶q2
¥i±±Öº80173-007-01 ¬ü°êù§J³º¸ 3
IP-LXM45Z-4 ¼Æ¶q1
mcm23c-gec-07 ¼Æ¶q1
ATS48C11Q »O 1
ATS48C17Q »O 1
7MF4033-1DA10?~1.6MPa »O 1
7MF4033-1EA50-2AB6?~0.4MPa »O 1
6SL3210-5BB17-5UV1 6»O
6AV6648-0CC11-3AX0 6»O
PP5003 GNT0137010R0004 ¡A2Ó ABB
TSXETG100 ¡A16Ó
750-P5-G5-D5-HI-A20-R ,2Ó¡A GE
6ES7972-0CA11-0XA0 ,2Ó
6SL3054-0EG00-1BA0-Z Z=S0110 10»O
A9F77216 1
6AV2181-8XP00-0AX0 2
6ES7511-1AK02-0AB0 1
6ES7511-1AK01-0AB01
6ES7 313-6CG04-0AB03
6GK1901-1BB10-2AA02
6ES7 954-8LE03-0AA0 1
CMC-PD01(RS485³q°T¥d¥ó) 1
6ES7953-8LC03-0AA0 1
6ES7590-1AC40-0AA0 1
972-0BB41-0XA03
6AV2124-0MC01-0AX0 (°t±a»PPLC³s±µ¹qÆl) 2
GM50A004101CR1BV/500 SCCM «~µP¡GMKS 2
GM50A004101CR1BV/2000 SCCM «~µP :MKS 1
SAM40150D 10
317-2EK13-0AB0 1
DCS800-S02-0025-04
DCS800-S02-0260-04
HDA4840-A-350-424 ¼Æ¶q2
³q«H±µ¤f¼Ò¥óPNI800 ±a©³®yABB 2¥ó
6DD1681-0CA2 ¼Æ¶q1
R900241991 1
SGMAH-01BBAB1¦w¤t 2
SGMCS-04C3C11¦w¤t 2
¬y¶qpFEP321.65.A.1.S.1.D2.D.1.A.1.S.2.A.1.B.O.Y.1.AABB6
¬y¶qpFEP321.80.A.1.S.1.D2.D.1.A.1.S.2.A.1.B.O.Y.1.AABB6
¬y¶qpFEP321.200.A.1.S.1.D2.D.1.A.1.S.2.A.1.B.O.Y.1.AABB2
¬y¶qpDn300¡APn16¡AFEP321300G/ABB3K67(°ª·Å)ABB2
6GK7243-1EX01-0XE0 2.0 Ó
AEROQUIP 100078934
AEROQUIP 100078935x
6SL3244-0BA20-IPA03
6SE6400-4BD16-5CA01
2094-BC07-M05-S 60204 1Ó
SNQ3NN/033RN11DB P1E9E8NNNN/NNNN JUN 17 1Ó
MQDS043A1A 1
MUDS043A1A 1
2094-BC04-M03-S
¦èªù¤l ÅÜÀW¾¹¥DªOA5E00677643
½sµ{±±¨î¾¹¼Ò¶ôABB?GJR5252100R0261?07KT94?H4
6RM7095-3KS02-0-Z
A40+D36+D42+D43+F20+F31+F50+F74+W37+W92 1
F2-04AD-1¼Æ¶q2
RP2NL355 1 ¥¼µ|
S-284DDR4-URDIMM
6EP3322-6SB00-0AY0 ¼Æ¶q1
1LE1501-2BB23-3JB4-Z 225M 1Ó
AF580-30 1
6av6645-0ab01-0ax0 ¼Æ¶q1
PM866AK01
20BC056A0AYNANC0
PM856AK01
PM861A01