²£¦a¡Gddhc0076 |
¤½¥q:¤j¼w¶×¦¨¬ì§Þ¡]·Hªù¡^¦³¤½¥q
Áp«Y¤H:¾H¦tµ¾
¤â¾÷:18250753807
¹q¸Ü:086-18250753807
¶Ç¯u:--
QQ:3448535365 ©M§Ú§Y®É¥æ½Í
¦a§}:´òùذϪ÷ÄÁ¸ô11¸¹1301«Ç¤§¤G
3ABD00019966 DCS800-S01-0020-04
3ABD00019968 DCS800-S01-0045-04
3ABD00019970 DCS800-S01-0065-04
3ABD00019972 DCS800-S01-0090-04
3ABD00019974 DCS800-S01-0125-04
3ABD00019976 DCS800-S01-0180-04
3ABD00019978 DCS800-S01-0230-04
3ABD00019981 DCS800-S01-0315-04
3ABD00019984 DCS800-S01-0405-04
3ABD00019986 DCS800-S01-0470-04
3ABD00019990 DCS800-S01-0610-04
3ABD00019992 DCS800-S01-0740-04
3ABD00019994 DCS800-S01-0900-04
3ABD00019997 DCS800-S01-1200-04
3ABD00019998 DCS800-S01-1500-04
3ABD00019999 DCS800-S01-2000-04
3ABD00019967 DCS800-S02-0025-04
3ABD00019969 DCS800-S02-0050-04
3ABD00019971 DCS800-S02-0075-04
3ABD00019973 DCS800-S02-0100-04
3ABD00019975 DCS800-S02-0140-04
3ABD00019977 DCS800-S02-0200-04
3ABD00019979 DCS800-S02-0260-04
3ABD00019983 DCS800-S02-0350-04
3ABD00019985 DCS800-S02-0450-04
3ABD00019987 DCS800-S02-0520-04
3ABD00019991 DCS800-S02-0680-04
3ABD00019993 DCS800-S02-0820-04
3ABD00019995 DCS800-S02-1000-04
3ABD00019997 DCS800-S02-1200-04
3ABD00019998 DCS800-S02-1500-04
3ABD00019999 DCS800-S02-2000-04
500V¡A2¶H
3ABD00019966 DCS800-S01-0020-05
3ABD00019968 DCS800-S01-0045-05
3ABD00019970 DCS800-S01-0065-05
3ABD00019972 DCS800-S01-0090-05
3ABD00019974 DCS800-S01-0125-05
3ABD00019976 DCS800-S01-0180-05
3ABD00019978 DCS800-S01-0230-05
3ABD00019981 DCS800-S01-0315-05
3ABD00019984 DCS800-S01-0405-05
3ABD00019986 DCS800-S01-0470-05
3ABD00019990 DCS800-S01-0610-05
3ABD00019992 DCS800-S01-0740-05
3ABD00019994 DCS800-S01-0900-05
3ABD00019997 DCS800-S01-1200-05
3ABD00019998 DCS800-S01-1500-05
3ABD00019999 DCS800-S01-2000-05
500V¡A4¶H
3ABD00019967 DCS800-S02-0025-05
3ABD00019969 DCS800-S02-0050-05
3ABD00019971 DCS800-S02-0075-05
3ABD00019973 DCS800-S02-0100-05
3ABD00019975 DCS800-S02-0140-05
3ABD00019977 DCS800-S02-0200-05
3ABD00019979 DCS800-S02-0260-05
3ABD00019983 DCS800-S02-0350-05
3ABD00019985 DCS800-S02-0450-05
3ABD00019987 DCS800-S02-0520-05
3ABD00019991 DCS800-S02-0680-05
3ABD00019993 DCS800-S02-0820-05
3ABD00019995 DCS800-S02-1000-05
3ABD00019997 DCS800-S02-1200-05
3ABD00019998 DCS800-S02-1500-05
3ABD00019999 DCS800-S02-2000-05
600V¡A2¶H
3ABD00019980 DCS800-S01-0290-06
3ABD00019989 DCS800-S01-0590-06
3ABD00019996 DCS800-S01-0900-06
3ABD00019998 DCS800-S01-1500-06
3ABD00019999 DCS800-S01-2000-06
3ABD00020796 DCS800-S01-2050-06
600V¡A4¶H
3ABD00019982 DCS800-S02-0320-06
3ABD00019988 DCS800-S02-0650-06
3ABD00019996 DCS800-S02-0900-06
3ABD00019998 DCS800-S02-1500-06
3ABD00020796 DCS800-S02-2050-06
690V¡A2¶H
3ABD00019996 DCS800-S01-0900-07
3ABD00019998 DCS800-S01-1500-07
3ABD00019999 DCS800-S01-2000-07
3ABD00020796 DCS800-S01-2050-07
690V¡A4¶H
3ABD00019996 DCS800-S02-0900-07
3ABD00019998 DCS800-S02-1500-07
3ABD00020796 DCS800-S02-2050-07
±±¨î½L©M³q°T¥i¿ï¥ó
±±¨î½L©M¦w¸Ë²Õ¥ó
DCS800-PAN±±¨î½L¬O¼Ò¶ôªº¼Ð·Ç°t¸m
ACS/H-CP-EXT±±¨î½L¦w¸Ë²Õ¥ó(§t3¦Ì¹qÆl)
DCS800-PAN¥i´¡©Þ¦w¸Ë²Õ¥ó(§t3¦Ì¹qÆl¡AODPI-01¾A°t¾¹)3ABD00021073
³q°T¥i¿ï¥ó
RPBA-01PROFIBUS-DP
RDNA-01DeviceNet
RCAN-01CANopen
RCNA-01ControlNet
RMBA-01Modbus
ÂX®iI/O¤ÎÄ~¹q¾¹¿é¥XªºÂX®iI/O
RAIO-01Analog I/O Extension
RDIO-01Digital I/O Extension
AIMA-01I/O Extension Adapter
§Ö³t¥úÅÖDDCS³q°T¼Ò¶ô Module COM-8x
SDCS-COM-81Modulebus 10Mbd3ABD00020799
SDCS-COM-82¥Î©ó¥H«eªºNxxA«Y¦C³q°T¾A°t¾¹3ABD00020800
¶Ç°Ê¦ê¦æ³q°T±µ¤fªO
SDCS-DSL-4Serial Communication Built in3ABD00020798
¥Î©ó¥~³¡ºÏ³õ¡B¥D±q¡B12¬Û³s±µ¤ÎÂI¹ïÂI³q°T
±µ¤fªO¡A´ú¶qªO¤ÎIOB-2x/IOB-3ªº¦w¸Ë¥ó
±aÒ\¼hªºI/O¼Æ¦r¶q±µ¤fªO
SDCS-IOB-21-coat §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X124...48V DC3ABD00021074
SDCS-IOB-22-coat §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X1115V AC3ABD00021075
SDCS-IOB-23-coat §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X1230V AC3ABD00021076
SDCS-IOB-3-coat §t¨â®Ú1.7mªø«ó¥¹qÆlX1=>X1&X2=>X23ABD00021077
·í¦P®É¨Ï¥ÎIOB-2x-coat©MIOB-3-coat®É¡A»Ýn¤T®Ú26ªäªº«ó¥¹qÆl
SDCS-IOB-21 + IOB-3-coat §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021078
SDCS-IOB-22 + IOB-3-coat §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021079
SDCS-IOB-23 + IOB-3-coat §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021080
¼Ð·ÇªºI/O¼Æ¦r¶q±µ¤fªO
SDCS-IOB-21 §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X124...48V DC3ABD00021081
SDCS-IOB-22 §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X1115V AC3ABD00021082
SDCS-IOB-23 §t¤@®Ú1.7mªø«ó¥¹qÆlX1=>X1230V AC3ABD00021083
SDCS-IOB-3 §t¨â®Ú1.7mªø«ó¥¹qÆlX1=>X1&X2=>X23ABD00021084
·í¦P®É¨Ï¥ÎIOB-2x©MIOB-3®É¡A»Ýn¤T®Ú26ªäªº«ó¥¹qÆl
SDCS-IOB-21 + IOB-3 §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021085
SDCS-IOB-22 + IOB-3 §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021086
SDCS-IOB-23 + IOB-3 §t¨â®Ú1.7m¡B¤@®Ú0.5¦Ìªø«ó¥¹qÆl3ABD00021087
IOB-2x/IOB-3¦w¸Ë¥ó§t±µ¦a¥À±Æ¤ÎÁ³°vµ¥¤Ø¤o WXDXH =>290x19x218mm3ABD00021088
SDCS-FEX-425-INT3x500V AC25A¥i¤º¸m+S16413,000
¥i³æ¿WÁʶR3ABD00021043
¥~¸m¤T¬Û¥b±±ºÏ³õ¡A¤£¥i°f¡A¤j¶i½u¥æ¬y¹qÀ£525V¡A¶È¾A¥Î©óD3...D4/600V©MD5...D7, 900A...5200Aªº¼Ò¶ô
¤]¥i¥H¥Î©óD1...D4¼Ò¶ô¡A¦¹®ÉÀ³±N¼Ò¶ô¤ºªº¤º¸mºÏ³õ«Ì½ª¡C
DCF803-00353x500V AC35A¥~¸m3ABD0002104414,500
DCS800/CON-4¥D±±ªO»P¥~³¡³æ¬ÛºÏ³õ¡A¤T¬ÛºÏ³õ¡A12¬Û³s±µ¡A¥D±q±±¨îªº³s±µ¹qÆl
Cable Fex-4 - DSL 0.54m 3ABD000210471,200
Cable Fex-4 - DSL 4m 3ABD000210481,500
³æ¬Û¾ã¬yºÏ³õ
¥~¸m³æ¬Û¥b±±ºÏ³õ¡A¤£¥i°f
DCF503B005050A¥~¸m3ABD0002104519,900
¥~¸m³æ¬Û¥þ±±ºÏ³õ¡A¥i°f
DCF504B005050A¥~¸m3ABD0002104623,200
¦Û½¢ÅÜÀ£¾¹
¦Û½¢ÅÜÀ£¾¹400V, 415V, 460V and 500V
T3.017A AC3ABD100142394,500
T3.0213A AC3ABD000092015,700
T3.0317A AC3ABD100144686,800
T3.0433A AC3ABD100144769,600
T3.0557A AC3ABD1001445013,000
¦Û½¢ÅÜÀ£¾¹525V, 575V, 600V and 690V
T3.117A AC3ABD000092025,100
T3.1317A AC3ABD100171817,900
T3.1433A AC3ABD1001719012,400
T3.1557A AC3ABD1001720315,200
»²§U¹q·½ÅÜÀ£¾¹T2 380...690V=>115/230V¡A³æ¬Û
T2-EI 1501400VA 3ABD100175563,700
¶i½u¹q§Ü¾¹
3x400/500/525V AC
20 / 25A DCND0118A/512uH3ABD000088213,300
45 / 50A DCND0237A/250uH3ABD000088223,700
65 / 75A DCND0455A/168uH3ABD000088244,800
90 / 100A DCND06102A/90uH3ABD000088266,300
125 / 140A DCND06102A/90uH3ABD000088266,300
180 / 200A DCND07184A/50uH3ABD000088277,100
230 / 260A DCND07184A/50uH3ABD000088277,100
315 / 350A DCND09 245A/37.5uH3ABD000088299,300
405 / 450A DCND10367A/25.0uH3ABD0000883011,600
470 / 520A DCND10 367A/25.0uH3ABD0000883011,600
610 / 680A DCND12490A/18.8uH3ABD0000883216,100
740 / 820 A DCND13698A/18.2uH3ABD0000883318,900
900 / 1000A DCND13698A/18.2uH3ABD0000883318,900
1200A DCND14930A/9.90uH3ABD0000883424,400
1500A DCND151163A/10.9uH3ABD0000883529,300
2000A DCND161510A/6.10uH3ABD0000883637,800
3x600V AC
290 / 320A DCND08 196A/56.3uH3ABD000088239,000
590 / 650A DCND13698A/18.2uH3ABD0000883318,900
3x600...690V AC
900A DCND13698A/18.2uH3ABD0000883318,900
1500A DCND151163A/10.9uH3ABD0000883529,300
2000A DCND16 *1510A/6.10uH3ABD0000883637,800
*±j¨î·§N
º²Â_¾¹
20...1000A¼Ò¶ô¥i¿ï¥Îªº§Ö³tº²Â_¾¹¡A»ù®æ¥]¬A¤T¥uº²Â_¾¹
DCS800 D5,D6©MD7¼Ò¶ô(900A-5200A)¤º³¡¸Ë¦³º²Â_¾¹
400/500/525V¥æ¬y¶i½u3 pcs.
20 / 25A DC170M1564 - 50A/660V Blade or knife fuses3ABD09838767950
45 / 50A DC170M1565 - 63A/660V Blade or knife fuses3ABD000096881,000
65 / 75A DC170M1568 - 125A/660V Blade or knife fuses3ABD100126861,200
90 / 100A DC170M1568 - 125A/660V Blade or knife fuses3ABD100126861,200
125 / 140A DC170M3815 - 200A/660V Blade or knife fuses3ABD100126942,500
180 / 200A DC170M3816 - 250A/660V Blade or knife fuses3ABD100285742,700
230 / 260A DC170M3817 - 315A/660V Blade or knife fuses3ABD100305102,800
315 / 350A DC170M5810 - 500A/660V Blade or knife fuses3ABD100127083,900
405 / 450A DC170M6811 - 700A/660V Blade or knife fuses3ABD100127166,300
470 / 520A DC170M6811 - 700A/660V Blade or knife fuses3ABD100127166,300
610 / 680A DC170M6163 - 900A/660V Screw type fuses3ABD000294666,900
740 / 820A DC170M6163 - 900A/660V Screw type fuses3ABD000294666,900
900 / 1000A DC170M6166 - 1250A/660V Screw type fuses3ABD100127419,800
600V¥æ¬y¶i½u3 pcs.
290 / 320A DC170M5810 - 500A/660V Blade or knife fuses3ABD100127083,900
590 / 650A DC170M6813 - 900A/660V Blade or knife fuses3ABD100127246,900
±Ò°Ê¡A½Õ¸Õ¡A½sµ{©MºûÅ@¤u¨ã
DriveWindow Light Vers. 2.xx¬°ÀH¾÷¼Ð·Ç°t¸m
DCS800½Õ¸Õ©MºûÅ@¤u¨ã
DriveWindow 2.2x¤ÎPCMCIA²Õ¥ó¨£ACS800¥i¿ï¥ó
¨Ï¥ÎDriveWindow»Ýn¦P®É¿ï¥ÎSDCS-COM-8xªO
PCI/PCMCIA Adapter (Used for Desktop)¨£ACS800¥i¿ï¥ó
IEC61131 ½sµ{
DCS800¥i½sµ{¥d¤º¸m+S2005,100
SDCS-MEM-8¥i³æ¿WÁʶR3ABD000207975,100
³æ¬ÛªºDCS800 Demo Case3ABD0002109666,000
¨÷¨ú³n¥ó¥](¸Ë©ó¥i½sµ{¥dSDCS-MEM-8¤º)
SDCS-MEM-8+WiIT for Experts¤º¸m+S2027,600
¥i³æ¿WÁʶR3ABD000252117,600
¥_¨Ê®É¶¡6¤ë10¤é¡A¾ÚNBA°OªÌ¬d©Ô¥§¨È³ø¹D¡A¬¥§üÁF´ò¤H¶¤¦b¦hÓ¤£¦Pªº®É¶¡ÂI³£¦³·N³q¹L¥æ©ö±o¨ì©_¤~¶¤ªº©ú¬P«á½Ã¥¬©Ô¼w§Q-¤ñº¸