§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~³]³Æ
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~³]³Æ ¨ä¥¦ ABB¥À½u±±¨î³æ¤¸¼Ò¶ôBCU06-ETH ³ø»ù¸Ô±¡ 10

ABB¥À½u±±¨î³æ¤¸¼Ò¶ôBCU06-ETH ³ø»ù¸Ô±¡

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

ABB¹q¸ôªO BCU06-ETH C7 1SAP140100R1170

?BCU06-ETH ¬O ABB «~µPªº¤@´Ú¥À½u±±¨î³æ¤¸¼Ò¶ô

BCU06-ETH ¬O¥À½u±±¨î³æ¤¸¡]Busbar Control Unit¡^ªº¥H¤Óºôª©¥»



?BCU06-ETH ¬O ABB «~µPªº¤@´Ú¥À½u±±¨î³æ¤¸¼Ò¶ô?¡A¥H¤U¬O¨ä¸Ô²Ó¤¶²Ð¡G

¤@¡B«~µP­I´º

ABB ¬O¹q¤O»P¦Û°Ê¤Æ§Þ³N»â°ìªº¥ø·~¡A´£¨Ñ¼sªxªº²£«~©M¸Ñ¨M¤è®×¡A¨ä¤¤¥]¬A PLC ³]³Æ¤Î¬ÛÃö¼Ò¶ô¡CBCU06-ETH §@¬° ABB ªº²£«~¡AÄ~©Ó¤F¨ä¡Bªº¯SÂI¡C

¤G¡B¼Ò¶ôÃþ«¬

BCU06-ETH ¬O¥À½u±±¨î³æ¤¸¡]Busbar Control Unit¡^ªº¥H¤Óºôª©¥»¡A¥D­n¥Î©ó¤¤§CÀ£°t¹qÂd¡B¼Æ¾Ú¤¤¤ß¡B¤u·~¦Û°Ê¤Æµ¥³õ´ºªº®Ö¤ß±±¨î¡C¥¦±Ä¥Î¼Ò¶ô¤Æ³]­p¡A¥i¿W¥ß³¡¸p©ó°t¹qÂd¤º¡A³q¹L¥H¤Óºô»P¤W¦ì¾÷¡]¦p ABB Emax 2 Â_¸ô¾¹¡BECC05 ¯à·½ºÞ²z¾¹¡^µLÁ_¶°¦¨¡A¹ê²{¡§¤À´²±±¨î¡B¶°¤¤ºÞ²z¡¨¡C

¤T¡B°Ñ¼Æ¸Ô±¡

  1. ?³q«H¨óij?¡G¤ä«ù IEC 61850¡BPROFINET¡BModbus TCP¡BDNP3 µ¥¦hºØ¤u·~³q«H¨óij¡A«K©ó»P¤£¦P«~µP©MÃþ«¬ªº³]³Æ¶i¦æ¼Æ¾Ú¥æ´«¡C

  2. ?ºôµ¸¦w¥þ?¡G¤ä«ù IEC 62443 ºôµ¸¦w¥þ¼Ð·Ç¡A³q¹L VLAN ¹jÂ÷»P AES ¥[±K³q«H¡A¦³®Ä¨¾¤î¼Æ¾ÚªnÅS»P«Dªk¾Þ±±¡A½T«O«Y²Î¦w¥þí©w¹B¦æ¡C

  3. ?­Ý®e©Ê?¡G¾A°t ABB ªº UniSec¡BMNS¡BOkken µ¥«Y¦C¤¤§CÀ£¶}ÃöÂd¡A¤ä«ù§Y´¡§Y¥Î¡A·¥¤j¦a¤è«K¤F¥Î¤áªº¦w¸Ë©M¨Ï¥Î¡C

  4. ?ÂX®i©Ê?¡G»P ABB Ability? EDCS ¯à·½ºÞ²z«Y²Î¡BEAM ³]³Æ¸ê²£ºÞ²z¥­»O²`«×¶°¦¨¡A´£¨Ñ¥iµø¤ÆºÊ±±¬É­±»P¹w´ú©ÊºûÅ@¥\¯à¡AÀ°§U¥Î¤á¹ê²{¯à·½ºÞ²zªº´¼¯à¤Æ©M¤Æ¡C

  5. ?Àô¹Ò¾AÀ³©Ê?¡G¨ã³Æ¥X¦âªºÀô¹Ò¾AÀ³©Ê¡A¯à°÷¦b´c¦Hªº¤u·~Àô¹Ò¤¤Ã­©w¹B¦æ¡A½T«O°t¹q«Y²Îªº¥i¾a©Ê©M¦w¥þ©Ê¡C

¥|¡BÀ³¥Î³õ´º

  1. ?¼Æ¾Ú¤¤¤ß?¡GBCU06-ETH ¥iºÊ´ú UPS ¿é¤J/¿é¥X¹qÀ£¡B¹q¬y¤Î¹q¯à½è¶q¡A³q¹L IEC 61850 ¨óij»P°Ê¤OÀô¹ÒºÊ±±«Y²Î¡]DCIM¡^Áp°Ê¡A¹ê²{¬G»Ù¹wĵ»P­t¸ü§¡¿Å¡A«O»Ù¼Æ¾Ú¤¤¤ßªº¨Ñ¹q³sÄò©Ê©M¯à®ÄÀu¤Æ¡C

  2. ?¤u·~¦Û°Ê¤Æ?¡G¦b¨T¨®¨î³y¡B¥b¾ÉÅé«Ê¸Ëµ¥°ªºë«×²£½u¤¤¡ABCU06-ETH ¥i¹ê®ÉºÊ´ú¹q¾÷ÅX°ÊÂdªº¹qÀ£ªi°Ê»P¿Óªi¡A³q¹L PROFINET ¨óij»P PLC ¨ó¦P±±¨î¡AÁ×§K¦]¹q¯à½è¶q°ÝÃD¾É­Pªº³]³Æ°±¾÷¡A´£°ª²£½uºî¦X®Ä²v¡C

  3. ?°Ó·~«Ø¿v?¡G¦b¼g¦r¼Ó¡BÁʪ«¤¤¤ßµ¥³õ´º¤¤¡ABCU06-ETH ¥i¶°¦¨¥ú¥ñ°fÅܾ¹¡BÀx¯à«Y²Î»P¥R¹q¼Î¼Æ¾Ú¡A³q¹L Modbus TCP ¨óij¤W¶Ç¦Ü¶³¥­»O¡AÀu¤Æ¤À¥¬¦¡¯à·½½Õ«×¡A¹ê²{ºñ¦â¯à·½ºÞ²z¡C

  4. ?°ò¦³]¬I?¡G¦b¾÷³õ¡BÂå°|¡B­y¹D¥æ³qµ¥³õ´º¤¤¡ABCU06-ETH ¥iºÊ´úÀ³«æ¹q·½«Y²Î¡]EPS¡^ªº¹qÀ£Ã­©w©Ê¡A³q¹L DNP3 ¨óij»P SCADA «Y²ÎÁp°Ê¡A½T«OÃöÁä­t¸ü«ùÄò¨Ñ¹q¡A¦uÅ@ÃöÁä¹q¤O¦w¥þ¡C



ÅX°Ê¾¹ªO¥dR911338543

¾¦½ü¬¦ R900932265 PGF2-22/006RE01VE4

REXROTHCDB02.1B-ET-EC-EC-NN-S4-S4-NN-NN-

¦øªA¹q¾÷ R911308684MSK030C-0900-NN-M1-UG1-NN

DBE6X-1X/315G24-8NZ4M

¦øªA¹q¾÷MSK030C-0900-NN-M1-UG0-NN synchronou

ÅX°Ê¼Ò¶ô,3842998038

REXROTHHMD01.1N-W0036-A-07-NNNN

---HMD01.1N-W0036-A-07-NNNN

REXROTHHMD01.1N-W0020-A-07-NNNN.

----HMD01.1N-W0020-A-07-NNNN

RexrothHSZ01.1-D08-D04-NNNN

ª½½u·Æ¶ô R162281420

¦U1

TPC070TD-B    1 

C129A501G01 FT1SW (FT1-C001)    10¥ó

---129A501G01

C774B430G20 FT1SW¡]FT1-C171¡^  20¥ó

ABB

6AG4140-1DL04-0DA0    1­Ó

3BSE008358R1   4

----PM510V16

TB810    2

1VFSK068889V300   76A3N11236EWB41  1VCF752000   14


6RA7018-6DV62-0-Z K11+K01+G95  1

¤u±±¾÷ IPC547J 6AG4104-5DA30-0AA0  1

SSBIET800   1   ABB

SPIET800   1

MVME61006E-0163 ¦ãÀq¥ÍEMERSON¼Ò¶ô

5­Ó

A5E33713857    1­Ó

A5E33032452    1­Ó


V30812-A5020-A6 


3RW4466-2BC44   1

EXECH20D    25

C98043-A7003-L1     2

3HAC046430-002        2

3HAC03021457-001/00   1

3HAC024488-001/03    1

BMECRA31210

BMXDDI3202K

BMXDDO3202K

BMEP584040S

BMXRMS004GPF

TCSESM083F2CS0

BMXSAI0410

BMXAMI0810

¦U1­Ó

GPAR-24 NBAI-A¼Æ¶q1

----GPAR-24NBA1

20BC015A0AYNANC0  40926   2

A20B-2003-0311/02A  1


IC200ALG630     1

IC200PWR102     4

IC200MDL241     2

IC200CPUE05       1

SRD991-BHNS1EA4NY-V01-LEXG-J   1

MX603-0408-613A    2

MVME61006E-0163  5


BCU-22    1

3BSE008546R1    1

2711P-RP2   18300    1­Ó

FSS200 7ME3950-5LF00  Siemens    4¥ó


¥ì¹yUPS/5P1150I ¼Æ¶q¡G1

A5E42836641    2

6SE7023-2ES87-2DA1    2

6ES7951-1KM00-0AA0    1

6GK5204-2BC10-2AA3    10


931N-T221     2164  1­Ó

SGMJV-04ADD6S  1

CF¥d    6FC5851-1XG40-3YA8¡A1­Ó



EMT40024X    1

DSE EH10.21SHZ   1

RJO08451              1

ABL4RSM24200   1

ABB  ÀË´úªO  ACBU-A1                10­Ó

ABB  ÀyºÏªOSDCS-FEX-2-0016    10­Ó

ABB  ÂoªiªOA70B2010ABBA-AAAAAA     5­Ó

FCA731PY-N02    1

GTC5150ND70K    1

SNB172FEGH1T    1

E12F22900    1

PCA505A087AF    1

4LFB-12825-2FC    1

BH00J343B     1

PCB505A041G    1

FDTC50VF/SRC50ZJX-S    1

6SE0102-1AA27-8AA5    2

6SE0102-1AA23-7AA5    2

6SL3210-1KE23-8UF1     

ETM-DPJ05SSFSA1-1SHGM-A12-10~10KPa    2

ETM-DRJ00SSFSA1-1SHGM-SA12~800Pa   2

ETM-CPZ09SS-3SLGM-A12~0.6MPa   2

ETM-CPZ04SS-3SLGM-A12~25KPa    1

AQUASYSTEM-VR24   5¥ó

SB330-50A1/114A9-330A  1¥ó

TPC070TD-B    1 

HARS700/100P   1

HARS700/260P   1

HARS700/310PII   1

POW ER2.180VDC24VA    5

WK-2/CN0504    9

SGM7J-02AFC6E   1


GDS1168-SFP-HCS-NF    1

CP3912-1009-0010   1  ­¿ºÖ

A20B-2101-0392/01A     

LB1LD03M55 2


IC693CPU313LTX ¥ó 15

52418423 MF13XM200-208P85100XRIP55    1

LDSTA-01    1


PLC±±¨î¾¹ 6ES7 226-2BD23-0XB0 ¥ó 1

½s½X¾¹ A-ZKD-13B-50BM/3P-G05L-J ­Ó 3

½s½X¾¹ A-ZKD-13B-50PM/3P-G05L-J ¥ó 2

½s½X¾¹ YH7030-19 ¥u 1

ÅÜÀ£¾¹ JTM150W28S20¡]090621¡^ ¥ó 3

¨®¸ü¨î®ñ¸Ë¸m TZ/Y-10W ¥ó 1

ùڷž¹ 3ST1-1 »O 76

­pºâ¾÷¥DªO MIC-3392MIL ¥ó 5

±±¨î¼Ò¶ô 6ES7 216-2BD23-0XB0 ¥ó 1

ÂX®i¼Ò¶ô 6ES7 232-0KD22-0XA0 ¥ó 1

ÅÞ¿è¼Ò¶ô 6ED1 052-2MD00-0BA6 ­Ó 1

6EP1434-2BA10 1»O

6SN2132-5KW11-1BA1    1

FBM232 1

FBM217 2

FBM242 2

FBM201 1

FBM237 1

FBM230 2

6ES7511-1AK02-0AB0

 CM900HG-130X     1

51196694-904 U1   2­Ó

0~10000psiinRF 15001bDC24V~20mA/HART0-F827-03-01HONEYWELL

0~15000psi.5"FIG 1502DC24V~20mA0-F827-01

LN-5-C-M-FCFP

SUMMIT ELECTRONICSHPH-1300-0800A

SUMMIT ELECTRONICSHPH-1300-0150A  ¼Æ¶q¦U1­Ó

515-2AM02-0AB0   2

516-3FP03-0AB0   2

515-2AM02-0AB0   1

6SL3210-5FE12-0UF0   2

6SL3544-0FB21-1FA0   2

155-6AU01-0BN0   3

134-6JD00-0CA1   10

6GK5208-0BA00-2AC2   4

 6AV2143-6GA00-0SN0   1

¥i½sµ{±±¨î¾¹¡]PLC) 6ES 7214-1AG40-0XB0 39­Ó

¼ÒÀÀ¶qÂX®i¼Ò¶ô ¦èªù¤lPLC/S7-1200,6ES7241-1AH32-0XB0 39­Ó

24V¹q·½¼Ò¶ô 307-1EA01-0AA0,¦èªù¤l 39­Ó

JAMSC-120DAI74300 2


¥[¼ö¾¹255836 2 ­Ó


1794-IB32  6468  1

6ES7155-6A401-0BN0||    2

6ES7222-1HF32-0XB0||    2

MSK040B-0600-NN-S1-UP0-NNNN    1

MSK060C-0300-NN-S1-UP1-NNNN    1


Laetus LLS570-35   1


DigiTronic CamCon DC190   1

6ES7512-1DM03-0AB0    

METEOR2-MC/4   1


E3G-R17-G      5

E3G-ML19T-G     5

6SL3224-0BE17-5UA0    2                     

3HAC062338-004    1

SRB-MS-ILK5    1


HD22010-3   3

6GK7 343-1HX00-0XE0   1   ¦èªù¤l

WF53.40-16      1­Ó

6ES7235-0KD22-0XA8    

CJ1W-SCU41-V1    2 ­n«O¤ºªº³f

 SEW  BGE1.5    1


220T0084-100   1


FG2 AK-1024G-90G-NG    16

6ES7138-7FA00-0AB0     

  SQM48.497A9WH 20 Nm - 2 »O

504S5NRSS4 CAL#004     1

S-240-24     1 

SUCO F10G21-0399 - 3


RM6?NE?IDI 10?kV 630?A  - 4pcs

RM6?NE?IIDI 10?kV 630?A  - 4pcs

BWDK-3208BE/BA  1»O

MD330NT5.5GB-6 5.5KW AC380V    2

T281.72.X ITD 23 A 4 Y 2 128 H BX K10SK4 S 14   2

BH500-G4.0/P5.5T4-D 4.0/5.5KW    2

IS650NT032/UX-B    1

Lenze i950:I95AE240F1AV10Z0Q0 4KW 1

R88M-1M10030T-S2    1


IS650NT032IUX-B    1

Kromschroder Lago Basic 0201R V1 E-Nr 99-777-310  AC 230V 5VA T50,AC 250V 2(2)A II   1

Bl ase 5OL*M5Ox1,5/VG5 IIR44/P460( kompl    1

4¡B¹q·½¼Ò¶ô¡G«¬¸¹¡GIPMO25-B22-5A¡A°Ñ¼Æ¡Gª½¬y¿é¤J:220V/12.8A¡A¥æ¬y¿é¥X¡G220V/50HZ/10.9A¡A¥\²v:2500VA ¡B2250W¡A¥\²v¦]¯À:0.9¡C 1


BCU06-ETH is a busbar control unit module from ABB brand. The following is its detailed introduction:

1¡B Brand background

ABB is a leading global enterprise in the field of power and automation technology, providing a wide range of products and solutions, including PLC equipment and related modules. BCU06 ETH, as a product of ABB, inherits its high-quality and high-performance characteristics.

2¡B Module type

BCU06-ETH is the Ethernet version of Busbar Control Unit, mainly used for core control in medium and low voltage distribution cabinets, data centers, industrial automation and other scenarios. It adopts a modular design and can be independently deployed in the distribution cabinet. It seamlessly integrates with the upper computer (such as ABB Emax 2 circuit breaker, ECC05 energy manager) through Ethernet, achieving "decentralized control and centralized management".

3¡B Parameter details

Communication Protocol: Supports multiple industrial communication protocols such as IEC 61850, PROFINET, Modbus TCP, DNP3, etc., facilitating data exchange with devices of different brands and types.

Network Security: Supports the IEC 62443 network security standard, effectively preventing data leakage and illegal manipulation through VLAN isolation and AES encrypted communication, ensuring the safe and stable operation of the system.

Compatibility: Suitable for ABB's UniSec, MNS, Okken and other series of medium and low voltage switchgear, supporting plug and play, greatly facilitating user installation and use.

Scalability: with ABB Ability ?  The EDCS energy management system and EAM equipment asset management platform are deeply integrated, providing a visual monitoring interface and predictive maintenance functions to help users achieve intelligent and refined energy management.

Environmental adaptability: With excellent environmental adaptability, it can operate stably in harsh industrial environments, ensuring the reliability and safety of the power distribution system.

4¡B Application scenarios

Data Center: BCU06-ETH can monitor UPS input/output voltage, current, and power quality. It is linked with the Power Environment Monitoring System (DCIM) through the IEC 61850 protocol to achieve fault warning and load balancing, ensuring the continuity of power supply and energy efficiency optimization of the data center.

Industrial automation: In high-precision production lines such as automotive manufacturing and semiconductor packaging, BCU06-ETH can monitor the voltage fluctuations and harmonics of motor drive cabinets in real time. Through PROFINET protocol and PLC collaborative control, it avoids equipment downtime caused by power quality issues and improves the overall efficiency of the production line.

Commercial buildings: In scenarios such as office buildings and shopping centers, BCU06-ETH can integrate photovoltaic inverters, energy storage systems, and charging pile data, upload them to the cloud platform through Modbus TCP protocol, optimize distributed energy scheduling, and achieve green energy management.

Infrastructure: In scenarios such as airports, hospitals, and rail transit, BCU06-ETH can monitor the voltage stability of the emergency power supply system (EPS), and is linked to the SCADA system through the DNP3 protocol to ensure continuous power supply to critical loads and safeguard critical power safety.


Áp«Y¤è¦¡
  • Áp«Y¤H¡G ±iªF²M ¥ý¥Í
  • ¾¦ì¡G ¾P°â¸g²z
  • ¶Ç ¯u¡G 0592-6535181
  • ¹q¸Ü¡G 0592-7796665
  • ¤â¾÷¡G 18050108093
  • ¦a §}¡G ºÖ«Ø¬Ù ·Hªù¥« ·Hªù¥«®ü·É°Ï®õ¦a®ü¦è1803
¤½¥q²¤¶
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H