MVI56E-MCM¼Ò¶ô¥iij»ù
MVI56E-MCM¼Ò¶ô¥iij»ù
MVI56E-MCM¼Ò¶ô¥iij»ù
MVI56E-MCM¼Ò¶ô§Þ³N³W®æ
MVI56E-MCM¼Ò¶ôÀ³¥Î»â°ì
MVI56E-MCM¼Ò¶ô²£«~¯S©Ê
MVI56E-MCM¼Ò¶ô¥«³õÁͶÕ
MVI56E-MCM¼Ò¶ô·§z
MVI56E-MCM¼Ò¶ô¬O¥ÑProSoft¤½¥q¥Í²£ªº¤@´Ú³q°T¼Ò¶ô¡A¥¦¥Dn¥Î©óù§J³º¸¦Û°Ê¤ÆControlLogix³B²z¾¹»PModbus RTU/ASCII³]³Æ¤§¶¡ªºModbus¥D¯¸©M/©Î±q¯¸³s±µ¡C¸Ó¼Ò¶ô¤ä«ù¦hºØ³q«H¨óij¡A¥]¬AModbus TCP/IP¡BEtherNet/IP¥H¤ÎDF1µ¥¡A¯à°÷ÆF¬¡¾AÀ³¦UºØºôµ¸Àô¹Ò¡C
¥\¯à¯SÂI
MVI56E-MCM¼Ò¶ô¨ã¦³¥H¤U¥Dn¥\¯à¯SÂI¡G
°ª¡P¯à³q«H¡G¼Ò¶ô¨ã³Æ°ª³t¶Ç¿é¯à¤O©Méw©Ê¡A¼Æ¾Ú¶Ç¿é³t«×©M·Ç½T©Ê¹F¨ì¦æ·~¤ô¥¡C¤ä«ù¦hºØºôµ¸©Ý¼³µ²ºc¡A¦p¬P«¬¡BÀô«¬¡BÁ`½u«¬µ¥¡A¬°¥Î¤á´£¨Ñ§ó¦hªººôµ¸¥¬§½¿ï¾Ü¡C
°t¸mÆF¬¡©Ê¡G¨CӺݤf³£¥i¥H®Ú¾Ú¹ê»Ú»Ý¨D°t¸m¬°¥DºÝ¤f©Î±qºÝ¤f¡A³oºØ³]p¨Ï±o¥Î¤á¯à°÷®Ú¾Ú¹ê»ÚªºÀ³¥Î³õ´ºÆF¬¡½Õ¾ãºÝ¤f°t¸m¡A¹ê²{¡P¨Îªº³q«H®ÄªG¡C
±j¤jªºIªO¥\¯à¡GMVI56E-MCM¼Ò¶ô¥i¥H»PControlLogixIªOµLÁ_¶°¦¨¡A¨ÏModbus Q¼Æ¾Úª½±µÅã¥Ü¬°³B²z¾¹ªºI/O¼Æ¾Ú¡C¦P®É¡A¥¦¥i¥H»PControlLogix«Y²Î¿Ä¦X¡A²¤Æ¤F«Y²Î¶°¦¨¹Lµ{¡A°§C¤FºûÅ@¦¨¥»¡C
¼W±jªº¯S©Ê©MÆF¬¡©Ê¡G±Ä¥ÎRSLogix 5000ª©¥»16©Î§ó°ªª©¥»ªº¥Î¤á¦Û©w¸q«ü¥O¡A¸`¬Ù¶}µo®É¶¡©M¦¨¥»¡C¤ä«ùCIPconnect ProSoft Configuration Builder³n¥ó¡]PCB¡^¡A¤ä«ùCIPconnect§Þ³N¡A¯à°÷³q¹Lù§J³º¸¦Û°Ê¤Æ1756-ENBT¼Ò¶ô¤è«K¦a¹ê²{ControlLogixIªO¶¡ªº»·µ{¥Î¤á³X°Ý¡C°t¸m¡B¶EÂ_©M¤ÀªR¹Lµ{¼Æ¾Ú©M³q«Hª¬ºA¡C
¦V«áÝ®e©Ê¡G©Ò¦³MVI56E²£«~³£¦V«áÝ®e¦´ÁªºMVI56¼Ò¶ô¡A¤¹³\ª½±µ§ó´«¡AµL»Ý§ó§ï²{¦³±±¨î¾¹µ{§Ç¡C
À³¥Î³õ´º
MVI56E-MCM¼Ò¶ô¾A¥Î©ó¦UºØ»Ýn°ª³t¡Béw³q«Hªº³õ´º¡A¥H¤Î»ÝnÆF¬¡°t¸m©M©ö©ó¶°¦¨ªºÀ³¥Î³õ´º¡C¨Ò¦p¡A¥¦¥i¥H¥Î©ó¤u·~¦Û°Ê¤Æ±±¨î«Y²Î¤¤¡A¹ê²{¤£¦P³]³Æ¤§¶¡ªº¼Æ¾Ú¥æ´«©M³q«H¡C
ª`·N¨Æ¶µ
¦b¨Ï¥ÎMVI56E-MCM¼Ò¶ô®É¡A»Ýnª`·N¥H¤U´XÂI¡G
¹q·½n¨D¡G¼Ò¶ôªº¹q¬y¦b5vª½¬y®É¬°250mA¡A¦b24vª½¬y®É¬°2mA¡AIªOªºÁ`¥\¯Ón¨D¬°1.32¥Ë¡A¡P¤j¥\¯Ó¬°4.1W(60¢XC(140¢XF))¡C
Àô¹Ò¾AÀ³©Ê¡GMVI56E-MCM¼Ò¶ô±M¬°¼Ð·Ç¹Lµ{À³¥Î¦Ó³]p¡A¦ÓMVI56E-MCMXT«h±M¬°Logix-XT±±¨î¥»O³]p¡A¯à°÷¦b·¥ºÝÀô¹Ò¤¤¹B¦æ¡C
ºî¤W©Òz¡AMVI56E-MCM¼Ò¶ô¬O¤@´Ú¥\¯à±j¤j¡B°t¸mÆF¬¡¥B©ö©ó¶°¦¨ªº³q°T¼Ò¶ô¡A¾A¥Î©ó¦hºØ¤u·~¦Û°Ê¤ÆÀ³¥Î³õ´º¡C¥¦ªº°ª¡P¯à³q«H¯à¤O©M¦V«áÝ®e©Ê¨Ï±o¥¦¦¨¬°³\¦h¥Î¤áªº²z·Q¿ï¾Ü¡C
MVI56E-MCM module overview
The MVI56E-MCM module is a communication module produced by ProSoft. It is mainly used for Modbus master and/or slave connections between Rockwell Automation ControlLogix processors and Modbus RTU/ASCII devices. The module supports a variety of communication protocols, including Modbus TCP/IP, EtherNet/IP and DF1, etc., and can flexibly adapt to various network environments.
Features
The MVI56E-MCM module has the following main functional features:
High-performance communication: The module has high-speed transmission capability and stability, and the data transmission speed and accuracy reach the industry level. Supports a variety of network topologies, such as star, ring, bus, etc., providing users with more network layout choices.
Configuration flexibility: Each port can be configured as a master port or a slave port according to actual needs. This design allows users to flexibly adjust the port configuration according to actual application scenarios to achieve the best communication effect.
Powerful backplane function: The MVI56E-MCM module can be seamlessly integrated with the ControlLogix backplane, allowing Modbus Q data to be directly displayed as the processor's I/O data. At the same time, it can be integrated with the ControlLogix system, simplifying the system integration process and reducing maintenance costs.
Enhanced features and flexibility: Save development time and costs with RSLogix 5000 version 16 or later Add-On Instructions. Supports CIPconnect ProSoft Configuration Builder software (PCB), supports CIPconnect technology, and can easily achieve remote user access between ControlLogix backplanes through the Rockwell Automation 1756-ENBT module. Configure, diagnose and analyze process data and communication status.
Backward Compatibility: All MVI56E products are backward compatible with earlier MVI56 modules, allowing direct replacement without changes to existing controller programs.
Application scenarios
The MVI56E-MCM module is suitable for various scenarios that require high-speed and stable communication, as well as application scenarios that require flexible configuration and easy integration. For example, it can be used in industrial automation control systems to realize data exchange and communication between different devices.
Things to note
When using the MVI56E-MCM module, you need to pay attention to the following points:
Power requirements: The current of the module is 250mA at 5v DC and 2mA at 24v DC. The total power consumption requirement of the backplane is 1.32 watts, with a maximum power consumption of 4.1W (60¢XC (140¢XF)).
Environmental adaptability: The MVI56E-MCM module is designed for standard process applications, while the MVI56E-MCMXT is designed for the Logix-XT control platform and can operate in extreme environments.
To sum up, the MVI56E-MCM module is a powerful, flexible configuration and easy to assemble
ISSC 396-115 396115
MVI56E-MCM800MA 5.1 VD3MA 24VDC ASSY 1700092 ¼Æ¶q¡G2Ó
6AG1436-2BA10-7AA0 1
984-6DX01-0AA0 1
3RW3016-2BB04¡A4KW 1
3RW4047-2BB04,55KW 1
3RW5548-2HA04,315KW 1
6ES7511-1CK01-0AB0 2
G-280A ¥\²v:230W,¹q·½:380V ªø39cm¼e56cm 2
MT400/630 2
1785-ENET 47212 1
3BHB003041R0101 57
3BHB004661R0101 26
3BHB016371R0002 4
3BHE016113R0001 3
3BHE037864R0101 14
LCO250100P9643 12
3BHL000206P0001 2
3BHB045647R0007 17
3BHL000250P0001 1
3BHB016897R0005 8
3BHL000406P0003 3
3BHL000749P0001 8
3BHL000420P0001 4
3BHB045647R0009 2
3BHE040914R0101 95
3BHL000517P0003 2
3BHL000519P0003 2
3BHB015984R0001 8
3BHL000253P0001 2
PSTX170-690-70 1