§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~³]³Æ
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~³]³Æ ¨ä¥¦ TSXCTY2A 1

TSXCTY2A

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

TSXCTY2A 

ÀHµÛ¨î³y·~§Þ³N¤ô¥­ªºµo®i¡A¹ï²{¥N¨î³y§Þ³Nªº¦UÃþ¾÷¾¹¤Hªº»Ý¨D¤é¯q¼W¥[¡C¦p¤j«¬¤uµ{¾÷±ñ¡B¨T¨®¡B®a¹qµ¥¦Û°Ê¤Æ¥Í²£½u¡A¥H¤Î´£¤É°ê®a°ª¬ì§Þ¾Ô²¤¦a¦ìªº²`®ü¸ü¤H¼ç¤ô¾¹ ¡B­À¤H­À¥Í¾÷¾¹¤H©M¼Qº£¡B©·²k¡BÂI²k¡B¸Ë°t ¡B·h¹B¤u·~¾÷¾¹¤Hµ¥¡C¬°¾÷¾¹¤HªºÃöÁä°t®M¶b©Ó¡A¹ï¾÷¾¹¤Hªº¹BÂ७í©Ê¡B­«´_©w¦ìºë«×¡B°Ê§@«×¥H¤Î¤u§@ªº¥i¾a©Êµ¥ÃöÁä©Ê¯à«ü¼Ð¨ã¦³­«­n¼vÅT¡C

¥Ø«e¡A¤u·~¾÷¾¹¤H¥Î¶b©ÓºØÃþ¸û¦h¡A¦pÁ¡¾À²`·¾²y¶b©Ó¡BÁ¡¾À¨¤±µÄ²²y¶b©Ó¡BÁ¡¾À¥|ÂI±µÄ²²y¶b©Ó©MÁ¡¾À¥æ¤eºu¤l¶b©Óµ¥¡C¥Ñ©óÁ¡¾À¥|ÂI±µÄ²²y¶b©Ó©M¾À¥æ¤eºu¤l¶b©Ó¨ã¦³©Ó¨üÁp¦X¸ü²ü¯à¤O±j¡Bºë«×°ª¡B¼¯À¿¤O¯x¤p¡B­«¶q»´¡B¹BÂ७íµ¥¯SÂI¡A¦]¦¹¤j¦h³QÀ³¥Î©ó¤u·~¾÷¾¹¤Hªº¸y³¡¡B¨y³¡¡BµÃ³¡µ¥³¡¦ì¡C

¤@¡BÁ¡¾À¥|ÂI±µÄ²²y¶b©Óµ²ºc§Î¦¡

¤u·~¾÷¾¹¤HÁ¡¾À¥|ÂI±µÄ²²y¶b©Ó³q±`¦³±a±K«Ê°é©M¤£±a±K«Ê°éªºµ²ºc§Î¦¡¡C¨ä¥D­n¥Ñ¤º°é¡B¥~°é¡B«O«ù¬[¡B¿û²y©Î«D±µÄ²¦¡±K«Ê°é²Õ¦¨¡C¤º¡B¥~°é§¡¬°¾ãÅéµ²ºc,¿û²y»P¤º¡B¥~°é·¾¹D§e¥|ÂI±µÄ²,«O«ù¬[¬°«a§Î´¡¤J¦¡µ²ºc¡C¾A¦X¦w¸Ë¦b¤u·~¾÷¾¹¤HªºµÃ³¡¡B¨y³¡µ¥Ãö¸`³¡¦ì¡C

¤G¡BÁ¡¾À±K«Ê¥|ÂI±µÄ²²y¶b©Ó¯SÂI

1¡B¥~®|»P¤º®|¤§¤ñ¸û¤p,ºu°ÊÅ骽®|¤p,¼Æ¶q¦h,»P¬Û¦P¤º®|ªº¼Ð·Ç¶b©Ó¬Û¤ñ,¨ä­«¶q¬ù¬°¼Ð·Ç¶b©Óªº5%,¾îºI­±¿n¬ù¬°¼Ð·Ç¶b©Óªº20%¡C

2¡B©wºI­±¶b©Ó:Á¡¾À¥|ÂI±µÄ²²y¶b©Ó«Y¦C,¶b©Ó¾îºI­±¤Ø¤o¬Û¦P,¤£ÀH¤º¡B¥~®|ªºÅܤƦӧïÅÜ¡C

3¡B¯à©Ó¨ü®|¦V¸ü²ü¡BÂù¦V±À¤O¸ü²ü©M¶ÉÂФO¯x,¬Û·í©ó¨â®M­I¹ï­I¦w¸Ëªº¨¤±µÄ²²y¶b©Ó,¦ý¨ä¼e«×¥u¬Û·í©ó¤@®M¨¤±µÄ²²y¶b©Óªº¼e«×¡C

¦Û±q20¥@¬ö60¦~¥N¾÷¾¹¤H¶i¤J¤u·~»â°ì¥H¨Ó¡AµL½×¬O¾÷¾¹¤Hªº¼Æ¶q¡AÁÙ¬O¾÷¾¹¤Hªº§Þ³N³£¦³¤F¨³²rªºµo®i¡C§@¬°¾÷¾¹¤HÃöÁä¹s°t¥ó°t®M¶b©Ó¡A°ê¥~¤@¨Ç¶b©Ó¤½¥q¦p¤é¥»ªºIKO¡BTHK¡BNSK©M¬ü°êKoydon®õ©M¶b©Óµ¥¦b20¥@¬ö80¦~¥N´N¤w¬ã¨î¥X¥Î©ó¾÷¾¹¤H¦U³¡¦ìªº«Y¦C¤Æ°t®M¶b©Ó¡A¬°¾÷¾¹¤H²£·~´£¨Ñ¤F80%¥ª¥k¯àº¡¨¬¾÷¾¹¤H»Ý­nªº°ò¦¤¸¾¹¥ó¡A¬°¤u·~¾÷¾¹¤Hªº¨³³tµo®i³þ©w¤F°í¹êªº°t®M§Þ³N°ò¦¡C

°ê¤º¤u·~¾÷¾¹¤H°t®M¶b©Ó¤j³¡¤À¨Ì¾a¶i¤f¡A¤Ö¼Æ¼t®aÁöµM¥Í²£¨î³y¤u·~¾÷¾¹¤H°t®M¶b©Ó¡A¦ý§å¶q¤p¡B«~ºØ³W®æ¤Ö¡A¹s³¡¥ó³q¥Î¤Æµ{«×§C¡A¨Ñ³f©P´Áªø¡A¦¨¥»°ª¡A¦Ó¥B½è¶q¤£Ã­©w¡A³o¨Ç¦]¯ÀÄY­«¨î¬ù¤F°ê¤º¤u·~¾÷¾¹¤H²£·~ªº¥¿±`µo®i¡C¬°°ê¤º¤u·~¾÷¾¹¤H¶b©Ó³]­p©M¥[¤u§Þ³Nªº´£°ª¡C

TSXCTY2A

TSXCTY2A 


Square D FDA34030 Circuit Breaker


Square D FDA34100 Circuit Breaker


Square D Q232125H Circuit Breaker 


Cutler Hammer LT20425 Panel Board Cover


Cutler Hammer LT20365 Panel Board Cover


Square D FAL34060, 60 Amp Circuit Breaker


Square D FCL340801021, Circuit Breaker w/ Shunt Trip


Square D FAL340601021, Circuit Breaker W/ Shunt Trip


Cutler Hammer CP4SBC510A2, 1000 Amp Tap Box


Cutler Hammer PRL-1A, 225 Amp MLO Panelboard (Interior)


Cutler Hammer PRL-1A, 400 Amp MLO Panelboard (Interior)


Cutler Hammer LTEZV2036SF Panel Board Cover


Cutler Hammer LTEZV2048SF Panel Board Cover


Square D HU366, 600 Amp, 600 Volt Non F Disconnect


Cutler Hammer LTDD2060S Panel Board Cover


Cutler Hammer LTDD2048F Panel Board Cover


Hubbell 460R7W,60 Amp Pin & Sleeve Recepticle


Hubbell 4100R9W, 100 Amp Pin & Sleeve Recepticle


Hubbell 4100R7W, 100 Amp Pin & Sleeve Recepticle


Levitron 560R9W, 60 Amp Pin and Sleeve Recepticle


Hubbell 560R9W, 60 Amp Pin & Sleeve Recepticle


Square D EHB34040 Circuit Breaker *NEW SURPLUS*


Cutler Hammer LTDD2048S Panel Board Cover


Cutler Hammer LT20485 Panel Cover *NEW IN BOX*


Allen Bradley Size 5 Starter, 509-FOD *


Allen Bradley Size 6 Starter, 509-G0B *


General Electric Size 5 Contactor, CR305GO**CAKH


General Electric Size 6 Contactor, CR305HHD**BA1H


Cutler Hammer HPG49755-A01, 800 Amp Tap Box 


Siemens 4300 Power Meter *


15 KVA, 1 Phase, 240x480 X 120/240 Volt Transformer


GS Hevi Duty 63 KVA SCR Drive Trans,460X460Y/?266, 3 Ph


Siemens 30 KVA Transformer, 480 x 120/208 Volt


Square D 45 KVA, 480/277 x 208 Volt Transformer


Federal Pacific 37.5 KVA,480X120/208 3 Ph, Trans


Áp«Y¤è¦¡
  • Áp«Y¤H¡G ¼Ú¶§ ¥ý¥Í
  • ¾¦ì¡G ¾P°â
  • ¶Ç ¯u¡G 0592-5917519
  • ¹q¸Ü¡G 0592-5709821
  • ¤â¾÷¡G 18030229050
  • ¦a §}¡G ºÖ«Ø¬Ù ·Hªù¥« ·Hªù¥«®ü·É°Ï·É´òªF¤@ùØ502¸¹702«Ç¤§¤@
¤½¥q²¤¶
¨ÑÀ³°Ó¨ä¥L¨ÑÀ³«H®§
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H
  • 01
  • §Ö³tµo¥¬¨DÁÊ«H®§
  • ¤U¤@¨B
  • 03
  • Áp«Ycnal«ÈªA¡G
  • ­P¹q¡G 0371-63388900
    °¨¤W±Ò°Ê±zªº§Ö³t±ÄÁʳq¹D¡I