Fluke Ti480¬õ¥~¬Û¾÷¥iij»ù
Fluke Ti480¬õ¥~¬Û¾÷¥iij»ù
Fluke Ti480¬õ¥~¬Û¾÷¥iij»ù
Fluke Ti480¬õ¥~¬Û¾÷À³¥Î
Fluke Ti480¬õ¥~¬Û¾÷©Ê¯à
Fluke Ti480¬õ¥~¬Û¾÷°Ñ¼Æ
Fluke Ti480¬õ¥~¬Û¾÷¥«³õµû»ù
Fluke Ti480¬õ¥~¼ö¹³»ö·§ªp
Fluke Ti480¬O¤@´Ú¥\¯à±j¤jªº¬õ¥~¼ö¹³»ö¡C
Fluke Ti480 °ò¥»©Ê¯à
±´´ú¾¹¤À¿ë²v¬°640x480¡]307,200¹³¯À¡^¡A¨Ã¥B¨ã³Æ¶W¹³¯À¥\¯à¡A¯à°÷®·®»¨Ãµ²¦X4¿¼Æ¾Ú¥H¥Í¦¨1280x960¡]614,400¹³¯À¡^ªº¹Ï¹³¡A´£¨Ñ§ó²M´·ªº¦¨¹³®ÄªG¡C
°t¦³¼Ð·ÇÃèÀYªºIFOV¡]ªÅ¶¡¤À¿ë²v¡^¬°0.93mRad¡AD:S¬°1065:1¡A¨ã³Æ¸û¦nªºªÅ¶¡¤À¿ë¯à¤O¡C
¼öÆF±Ó«×¡]NETD¡^¦b¥Ø¼Ð·Å«×30¢XC®É¡A 0.05¢XC¡]50mK¡^¡A¯à°÷ÀË´ú¥X·L¤pªº·Å«×®t²§¡C
·Å«×´ú¶q½d³ò¬° - 10¢XC¦Ü1000¢XC¡]14¢XF¦Ü1832¢XF¡^¡Aºë«×¬°¡Ó2¢XC©Î2%¡]¦b¼ÐºÙ·Å«×25¢XC¤U¡A¨ú¸û¤j¼ÆÈ¡^¡C
Fluke Ti480 ¹ïµJ¥\¯à
MultiSharp¦hÂI¹ïµJ¡G¦b¾ãÓµø³õ¤¤´£¨Ñ¦Û°Ê¹ïµJ¹Ï¹³¡A¥i¤j¤j®ø¡P¿ù»~¶EÂ_ªº¥i¯à¡A¯à©çÄá¾ãÓµø¨¤¤¤ªºªñµJ©M»·µJ¹Ï¹³¡C
LaserSharp¿E¥ú¦Û°Ê¹ïµJ¡G¤º¸m¿E¥ú´ú¶Z»ö¡A¥i¥Hpºâ¨ÃÅã¥Ü»P«ü©w¥Ø¼Ð¤§¶¡ªº¶ZÂ÷¡A±q¦ÓÀò±o©l²×¹ïµJ²M´·ªº¹Ï¹³¡C
¦P®ÉÁÙ¨ã³Æ¥ý¶iªº¤â°Ê¹ïµJ¥\¯à¡Aº¡¨¬¤£¦P³õ´º»Ý¨D¡C
Fluke Ti480 ¹Ï¹³¬ÛÃö¥\¯à
IRFusion¬õ¥~¥i¨£¥ú¿Ä¦X§Þ³N¡G¥i»´ªQ½Õ¾ã¥i¨£¹Ï¹³©M¬õ¥~¹Ï¹³ªº¿Ä¦X¡A¤è«K¥Î¤á¬d¬Ý©M¤ÀªR¡C
¹w®Õ·Ç¥i¿ïÃèÀY¡A¥]¬A2¿ªøµJÃèÀY¡B4¿ªøµJÃèÀY»P¼s¨¤ÃèÀY¡A¥i®·Àòªñ³B©Î»·³Bªº¹Ï¹³¡C
³q¹LIR - PhotoNotes¹Ï¤ù¼Ðª`«Y²Î¥i®·®»°Ñ¦Ò±ø¥ó©Î¹ê»Ú¦ì¸m©P³ò°Ï°ìªº¼Æ¦r¹Ï¹³¡A¨Ã¥BÁÙ¥i¥H³q¹L»yµªþª`¡]¨C´T¹Ï¹³¡Pªø60¬íªº¿ýµ¡A¥i¦b¼ö¹³»ö¤W¦^©ñ¬d¬Ý¡^ªº§Î¦¡±N¥ô¦ó¨ä¥L²Ó¸`«O¦s¨ì¤å¥ó¤¤¡A´î¤Ö²{³õ°µµ§°Oªº»Ýn¡C
Fluke Ti480 ¾Þ§@»P³]p
±Ä¥Î³æ¤â¾Þ§@¤âºj¦¡´¤§â³]p¡A¹ê²{§Ö³tªº¹ï·Ç©çÄᦡ¬G»Ù¶EÂ_¡A¦P®É¦³µÛ¾A¥Î©ó³æ¤â¨Ï¥ÎªºµÎ¾A¡P¥Î³]p¡A°t³Æ°í©T@¡Pªº3.5^¤o¡]¾î¦V¡^640x480LCDIJºN«Ì¡C
¨ã³Æ2¿©M4¿¼Æ½XÅܵJ¥\¯à¡A¤è«K¹ï¹Ï¹³¶i¦æÁY©ñ¬d¬Ý¡C
Fluke Ti480 ³n¥ó»P³s±µ©Ê
ÀHªþFlukeConnect SmartView®à±³n¥ó¡A³o¬O¤@Ó¡P±ªº¤¬Áp³n¥ó¥»O¡A¥i¥Î©óÀu¤Æ¼ö¹³¡B°õ¦æ¤ÀªR¡B¥Í¦¨§Ö³t¡B¥i©w¨î¡B¥i¾aªº³ø§i¥H¤Î®Ú¾Ú¥Î¤á¦b¶³ºÝ¿ï¾Üªº®æ¦¡¾É¥X¹Ï¹³¡AÁÙ¯à»PFluke Connect¶°¦¨¡]Fluke Connect¬O¥@¡P¤WÃe¤jªº³n¥ó©MºûÅ@¤u¨ã¶°¦¨«Y²Î¡^¡C
Ý®eFlukeConnectÀ³¥Îµ{§Ç¡A±N¼ö¹³»ö³s±µ¨ì´¼¯à¤â¾÷¡]iOS 4s¤Î§ó·sª©¥»¡AAndroid 4.3¤Î§ó·sª©¥»¡^¡A·|¦Û°Ê©çÄá¹Ï¹³¨Ã±N¹Ï¹³¤W¶Ç¨ìFlukeConnectÀ³¥Îµ{§Ç¥H¨Ñ«O¦s©M¦@¨É¡CÁÙ¥i¥H±N¼ö¹³»öÅã¥Üªº¤º®e¹ê®É¶Ç¿é¨ì´¼¯à¤â¾÷©ÎPC¨Ã»·µ{±±¨î¼ö¹³»ö¡A¤]¯à¥HµL½u¤è¦¡ª½±µ±q¼ö¹³»ö±N¹Ï¹³¦P¨B¨ìFlukeConnect«Y²Î¡A¨Ãªþ¥[¨ì¸ê²£°O¿ý©Î¤u§@³æ¡C
¥i³s±µ¦ÜPC¡BiPhone©MiPad¡]iOS 4s¤Î§ó·sª©¥»¡^¡AAndroid 4.3¤Î§ó·sª©¥»¡AWiFi³s±µ¦ÜLAN¡]¦p¦³´£¨Ñ¡^¡A¨ã³Æ¦hºØ¦sÀx¿ï¾Ü¡A¥i¨Ï¥Î¥i²¾°Ê4GB·L«¬SD¦sÀx¥d¡B4GB¤º¸m°{¦s¡A¥i«O¦s¨ìU½L¡A¥i¤W¶Ç¨ìFlukeCloudªø¤[¦sÀx¡A¤ä«ù¦hºØ¤å¥ó®æ¦¡¡]«D¿ç®g.bmp©Î.jpeg¡B¥þ¿ç®g.is2µ¥¡^¡C
Fluke Ti480 infrared thermal imaging camera overview
Fluke Ti480 is a powerful infrared thermal imaging camera.
Basic performance
The detector has a resolution of 640x480 (307,200 pixels) and has a superpixel function that can capture and combine 4 times the data to generate a 1280x960 (614,400 pixels) image, providing clearer imaging.
The IFOV (spatial resolution) equipped with a standard lens is 0.93mRad, and the D:S is 1065:1, which has good spatial resolution.
Thermal sensitivity (NETD) is 0.05¢XC (50mK) at the target temperature of 30¢XC, able to detect small temperature differences.
Temperature measurement range is -10¢XC to 1000¢XC (14¢XF to 1832¢XF) with an accuracy of ¡Ó2¢XC or 2% (whichever is greater at a nominal temperature of 25¢XC).
Focus function
MultiSharp Multi-Point Focus: Provides autofocus images across the entire field of view, greatly eliminating the possibility of false diagnoses and capturing near and far focus images across the entire field of view.
LaserSharp Laser Autofocus: Built-in laser rangefinder calculates and displays the distance to a specified target for always-in-focus images.
It also has advanced manual focus functions to meet the needs of different scenes.
Image related functions
IRFusion infrared and visible light fusion technology: The fusion of visible images and infrared images can be easily adjusted to facilitate user viewing and analysis.
Pre-calibrated optional lenses, including 2x telephoto, 4x telephoto and wide-angle lenses, capture images near or far.
The IR - PhotoNotes image annotation system captures digital images of areas around reference conditions or actual locations and can also record any image via voice annotation (up to 60 seconds of recording per image that can be played back on the thermal imaging camera). Additional details are saved to file, reducing the need for on-site note-taking.
Operation and design
It adopts a pistol grip design for one-handed operation to achieve rapid point-and-shoot fault diagnosis. It also has a comfortable and durable design suitable for one-handed use, and is equipped with a rugged and durable 3.5-inch (horizontal) 640x480 LCD touch screen.
Equipped with 2x and 4x digital zoom functions, it is convenient to zoom in and view images.
Software and connectivity
Comes with FlukeConnect SmartView desktop software, a comprehensive connected software platform for optimizing thermal imaging, performing analysis, generating fast, customizable, reliable reports and exporting images in user-selected formats in the cloud, with Fluke Connect Integration (Fluke Connect is the world's largest integrated system of software and maintenance tools).
Compatible with the FlukeConnect app, connect the thermal camera to your smartphone (iOS 4s and newer, Android 4.3 and newer), and images will automatically be captured and uploaded to FlukeCon
CI854AK01 3BSE030220R1
6SL3995-6AX00-0AA0
3BHT100011R0001
6SL3131-7TE31-2AA3
ELAU C400/A8/1/1/1/00
CX1020-N010
CX1020-0111
CX1100-0910
CX1100-0004
CX1100-0930
CX1030-N000
CX2100-0004
TWIN5-R53
TWIN8-R53
DCF803-0035
RED LION G310
CIMR-F7U4045
ATV61HC13N4
LD3600F
LES3600LSI
SCYC 56901
E82EV751K4C
E82EV752K4C
GE SKLA36AT0800
P225
P225CA0V112A0CA
P243
P243211B2M0C88K
P632
TSXETY410
MDX61B1320-503-4-00
MDx61B0750-503-4-00
6ES7317-7TK10-0AB0
P521B0GV112DE0
P521
VW3A4406
VW3A4408
VW3A4407