Fluke 1625-2¦a±´ú¸Õ»ö¥i±½Í
Fluke 1625-2¦a±´ú¸Õ»ö¥i±½Í
Fluke 1625-2¦a±´ú¸Õ»ö¥i±½Í
Fluke 1625-2¦a±´ú¸Õ»ö§Þ³N³W®æ
Fluke 1625-2¦a±´ú¸Õ»ö¨Ï¥Î³õ´º
Fluke 1625-2¦a±´ú¸Õ»ö¥«³õµû»ù
Fluke 1625-2¦a±´ú¸Õ»ö¥\¯à¯S©Ê
Fluke 1625-2 ¦a±´ú¸Õ»ö·§z
Fluke 1625-2 ¯SÂI
©ö©ó¾Þ§@¡G¨C¤@¦¸´ú¸Õ®É¡A´ú¸Õ»ö³£·|´£¥Ü©Ò»Ý¨Ï¥Îªº¦a¼Î©Î¹X¤f¡F¤j¤Ø¤o±ÛÂà¶}Ãö½T«O§Y¨ÏÀ¹µÛ¤â®M¤]¯à¾Þ§@¡C
USB¼Æ¾Ú¦sÀx©M¶Ç¿é¡G¯à°÷³q¹LUSBºÝ¤f¦sÀx©M¤U¸ü¼Æ¾Ú¡A¤º³¡¦sÀx¾¹¥i¦sÀx¦h¹F1500±ø°O¿ý¡C
Fluke 1625-2 ´ú¶q¥\¯à
µL¼Î´ú¸Õ¡]¶È¥Î¹X¤f¡^
´ú¶qì²z¡G¥u»Ý¨Ï¥Î¹X¤f§Y¥i´ú¶q±µ¦a¦^¸ô¹qªý¡C±N¨âÓ¹X¤f§¨¦b±µ¦a´Î¤W¡A¨CÓ¹X¤f§¡³s±µ¦Ü´ú¸Õ»ö¡A¨ä¤¤¤@Ó¹X¤f·PÀ³¤wª¾©T©w¹qÀ£¡A¥t¤@Ó¹X¤f´ú¶q¹q¬y¡AµM«á¦Û°Ê´ú©w±µ¦a´Îªº¹qªý¡C³oºØ¤èªk§¹¥þµL»Ý¨Ï¥Î±µ¦a¼Î¡A¥B¦b´ú¸Õ®ÉµL»ÝÂ_¶}±µ¦a´Î¡A«O«ù±µ¦a«Y²Î§¹¾ã©Ê¡C¦ý¦¹¤èªk¶È¾A¥Î©ó¨ü´ú«Ø¿vª«©Îºc¿vª«¤¤¦³±µ¦a«Y²Îªº±¡ªp¡A¦b¥u¦³¤@±ø³q¸ô±µ¦a¡]¦p³\¦h¦í¦vÀ³¥Î¡^®É¡AµLªk´£¨Ñ¥i±µ¨üªº¼ÆÈ¡A«h¡P¶·¨Ï¥Î¹q¦ì°´ú¸Õªk¡C
¾A¥Î³õ´º¡G¥i¥H¦b¤@¨Ç¤§«e±q¥¼¦Ò¼{¹Lªº¦ì¸m°õ¦æ±µ¦a´ú¸Õ¡A¥]¬A«Ø¿vª«¤º³¡¡B¹qÆl¶ð©Î¥ô¦óµLªk±µÄ²¨ì¤g¦aªº¦ì¸m¡C
¦hºØ±µ¦a´ú¶qÃþ«¬¡G¬O¤@´Ú¡P±ªº´ú¸Õ»ö¡A¥i¥H§¹¦¨©Ò¦³¥|ºØÃþ«¬ªº±µ¦a´ú¶q¡A¥]¬A¤T·¥©M¥|·¥¹q¦ì°¡]¨Ï¥Î¦a¼Î¡^¡B¥|·¥¤gÄ[¹qªý²v´ú¸Õ¡]¨Ï¥Î¦a¼Î¡^¡B¿ï¾Ü©Ê´ú¸Õ¡]¨Ï¥Î¦a¼Î©M1Ó¹X¤f¡^¡BµL¼Î´ú¸Õ¡]¶È¨Ï¥Î2Ó¹X¤f)¡C
Fluke 1625-2 §Þ³N°Ñ¼Æ
´ú¶q½d³ò¡G0.020£[¦Ü300k£[¡A¤£¦PªºÅã¥Ü½d³ò¦³¤£¦Pªº¤À¿ë²v¡A¦p0.001£[¦Ü2.999£[¤À¿ë²v¬°0.001£[¡B3.00£[¦Ü29.99£[¤À¿ë²v¬°0.01£[µ¥¡C
ºë«×¡G¡Ó(Ū¼Æªº2% + 2¦ì¼Æ)¡]¦b¬Y¨Ç´ú¶q¤¤¡^¡A¾Þ§@»~®t¬°¡Ó(Ū¼Æªº5% + 5¦ì¼Æ)¡C
´ú¶q®É¶¡¡G©T©wÀW²v®É³q±`¬°8¬í¡A¨Ï¥Î¦Û°ÊÀW²v±±¨î®É¡A¡P¤j30¬í§¹¦¨©Ò¦³´ú¶qÀW²v´`Àô¡C
¶}¸ô¹qÀ£¡G20/48V¥æ¬y¹q¡Aµu¸ô¹q¬y250mA¥æ¬y¹q¡A´ú¶qÀW²v¥i¤â°Ê©Î¦Û°Ê¿ï¾Ü94¡B105¡B111©M128Hz(AFC)¡A55Hz(R*) ¡C
¾¸Án§í¨î¡G120dB(162/3¡B50¡B60©M400Hz) ¡C
¡P¤j¹L¸ü¡G¡P¤jUrms=250V¡]±N¤£·|±Ò°Ê´ú¶q¡^¡C
Fluke 1625-2 °t®M³]³Æ¤Î®M¥ó
°t®M³]³Æ¡G¦pGeox±´ÀY¹qÆl¡B¨âÓ§¨¤l©M¾É½u²Õµ¥¡AÁÙ´£¨Ñ¥~±µÅܬy¾¹§@¬°¿ï¥ó¡A¦b´ú¶qºôª¬¹B¦æªº±µ¦a«Y²Î¤¤ªº³æÓ¤ä¸ô®É¡AÅܬy¾¹Åܬy¤ñ¬°80-1200:1¡A¥i¥H¦b¤£¤ÀÂ÷¬[ªÅ¦a½u©Î¬[½u¶ð©³³¡±µ¦a±aªº±¡ªp¤U´ú¶q°ªÀ£¿é¹q¬[½u¶ð¡A¤]¥i¥Î©ó¦b¤£¤ÀÂ÷³æÓ¨¾¹p¾É½uªº±¡ªp¤U´ú¶q¨¾¹p«Y²Î¡C
®M¥ó¤º®e¡G¨Ò¦pFluke1625-2KIT¥]¬A¡m¥Î¤á¤â¥U¡n¡B¡m**¶·ª¾¡n¡BQRG¡BGeox±´ÀY¹qÆl¡B¨âÓ§¨¤l¡B
Fluke 1625-2 Ground Tester Overview
1. Characteristics
Easy to operate: During each test, the tester will prompt which stake or jaw needs to be used; the large-size rotary switch ensures operation even when wearing gloves.
USB data storage and transfer: Ability to store and download data via USB port, internal memory can store up to 1500 records.
2. Measurement function
Stakeless testing (jaws only)
Measuring principle: Simply use the jaws to measure the ground loop resistance. Two jaws are clamped to the ground rod and each jaw is connected to the tester. One of the jaws senses a known fixed voltage and the other measures the current and then automatically determines the resistance of the ground rod. This method does not require the use of grounding stakes at all, and there is no need to disconnect the grounding rod during testing, maintaining the integrity of the grounding system. However, this method is only applicable if there is a grounding system in the building or structure being tested. When there is only one path to ground (such as many residential applications), it cannot provide acceptable values, and the potential drop test method must be used.
Suitable scenarios: Ground testing can be performed in locations never considered before, including inside buildings, on cable towers, or anywhere where there is no access to the ground.
Multiple Ground Measurement Types: A comprehensive tester that can complete all four types of ground measurements, including three-pole and four-pole potential drop (using ground stakes), four-pole soil resistivity testing (using ground stakes), Selective testing (using ground stakes and 1 jaw), non-stake testing (using only 2 jaws).
3. Technical parameters
Measuring range: 0.020£[ to 300k£[. Different display ranges have different resolutions, such as 0.001£[ to 2.999£[ with a resolution of 0.001£[, 3.00£[ to 29.99£[ with a resolution of 0.01£[, etc.
Accuracy: ¡Ó(2% of reading + 2 digits) (in some measurements), operating error ¡Ó(5% of reading + 5 digits).
Measurement time: usually 8 seconds when using a fixed frequency, and a maximum of 30 seconds to complete all measurement frequency cycles when using automatic frequency control.
Open circuit voltage: 20/48V AC, short circuit current 250mA AC, measurement frequency can be manually or automatically selected 94, 105, 111 and 128Hz (AFC), 55Hz (R*).
Noise suppression: 120dB (162/3, 50, 60 and 400Hz).
Maximum overload: Maximum Urms=250V (measurement will not be started).
4. Supporting equipment and kits
Supporting equipment: such as Geox probe cable, two clamps and conductor sets, etc. An external current transformer is also provided as an option. When measuring a single branch in a grounding system operating in a mesh, the current transformer has a conversion ratio of 80- 1200:1, can be used to measure high-voltage transmission towers without separating overhead ground wires or ground straps at the bottom of the tower, and can also be used to measure lightning protection systems without separating individual lightning protection conductors.
Kit contents: For example, Fluke1625-2KIT includes "User Manual", "Safety Instructions", QRG, Geox probe cable, two clamps,
SACE PR121/P E3H32 Iu = 3200A
IC755CSS12CDB
SACE PR121/P E3H08 Iu = 800A
SACE PR331/P X1N10 In=1000A
6SL3210-1PH31-4AL0
MPM-B1151F-MJ72AA
6SL3130-7TE23-6AA3
DHH805
CACR-120-PD1VDS01
6ES7414-2XL07-0AB0
6DD1607-0CA1
DAPU100 3ASC25H204
6AV2124-0QC02-0AX1
EPOWER/2PH-250A/600V/230V
Parker PM1-5E1-XD5
DST1405
095U2B300BACAA100190
PM856K01
1756HP-TIME/B
1756HP-TIME
671288-01
667633-01
671566-01
6GK5778-1GY00-0AA0
MDX61B0040-5A3-4-00
IS220PAICH1B
LXM62DU60D21000
PARKER AR-20AE
4D1084.00-090
4C2000.01-110
4E0020.01.090 & 4E0011.01-090
MC07B0075-5A3-4-00
CC-PCF901
CC-PCNT02
CC-SCMB02
CC-PUIO31
MVI56E-MNETR
VIA0701D02F0000
VIA1002C02A0000
6GK5788-2FC00-0AA0
6AV7894-0HG32-0AC0
VIA0703D01A0000
BATCHFLUX 5500 C
6ES7417-4HT14-0AB0
142U3E305BACAA165240
6SL3130-7TE28-0AA3
6SL3225-0BE37-5AA0
6ES7515-2RM00-0AB0
6SL3130-1TE31-0AA0
6SE7032-7EB87-2DA1
6AV2124-0JC01-0AX0
1KHL178025R0002
IC755CSS12CDB