Fluke 773夾式電流表可議價
Fluke 773夾式電流表可議價
Fluke 773夾式電流表可議價
Fluke 773夾式電流表市場評價
Fluke 773夾式電流表技術規格
Fluke 773夾式電流表功能特性
Fluke 773夾式電流表使用場景
Fluke 773夾式電流表簡介
Fluke 773 一、基本性能
Fluke 773 測量範圍相關
直流電流測量:Absolute·大直流電流測量為100mADCAbsolute·大直流電壓測量為30VDC,直流電流測量分辨率為10?ADC,具有較好的0.2%準確度和0.01mA分辨率和靈敏度。
可測電壓範圍:能測量0至30伏直流電壓,還可輸出1至5伏或0至10伏直流電壓信號,並且以線性斜坡或25%步進輸出電壓信號。
Fluke 773 測量功能特性
回路測量優勢:無需“斷開回路”即可測量4至20mA信號,這一特性可節省時間並避免影響係統運行,可用於測量PLC和控制係統模擬I/O的mA信號,還能同步24V回路供電並測量回路mA信號,可為傳送裝置供電並對其進行測試。
顯示功能:可顯示mA測量值和4至20mA量程百分比的雙背光顯示屏,測量聚光燈照亮黑暗機箱內難以發現的線路,便於操作和讀數。
特殊功能:具有“保持”功能可捕獲和顯示不斷變化的測量值,自動更改4至20mA輸出以便進行遠程測試,自動關閉、背光超時等省電功能可延長電池壽命。
多種測量模式:使用99.9mA量程可測量舊控制係統中的10至50mA信號,通過表筆“接入回路測量功能測量4至20mA信號,能將毫安培信號記錄到單獨的記錄設備,而無需斷開回路,輸出mA信號允許日志數字多用表或其它設備來記錄4至20mA信號,而無需斷開回路。
輸入輸出功能:有mA輸入/輸出功能,使用鉗表非斷線測量mA信號,並輸出mA信號源,將mA輸入信號應用到設備,然後在閥門或mA隔離器等設備上測量其4 - 20mA輸出。
Introduction to Fluke 773 Clip-on Ammeter
1. Basic performance
Measurement range related
DC current measurement: Absolute's maximum DC current measurement is 100mADCA. Absolute's maximum DC voltage measurement is 30VDC. The DC current measurement resolution is 10?ADC, with good 0.2% accuracy and 0.01mA resolution and sensitivity.
Measurable voltage range: It can measure 0 to 30 volts DC voltage, and can also output 1 to 5 volts or 0 to 10 volts DC voltage signal, and output the voltage signal with a linear slope or 25% step.
Measurement features
Loop measurement advantages: 4 to 20mA signals can be measured without "breaking the loop". This feature saves time and avoids affecting system operation. It can be used to measure mA signals of PLC and control system analog I/O, and can also synchronize 24V loops. Powers and measures loop mA signals to power and test transmission devices.
Display function: Dual backlight display that can display mA measurement value and 4 to 20mA range percentage. The measurement spotlight illuminates hard-to-find lines in the dark chassis for easy operation and reading.
Special features: Features a "Hold" function to capture and display changing measurements, automatically changes 4 to 20mA output for remote testing, and power-saving features such as auto-off and backlight timeout to extend battery life.
Multiple measurement modes: Use the 99.9mA range to measure 10 to 50mA signals in old control systems, measure 4 to 20mA signals through the "loop measurement function" of the test pen, and record milliamp signals to a separate recording device without disconnecting The open loop, output mA signal allows a logging DMM or other device to log a 4 to 20mA signal without breaking the loop.
Input and output function: There is mA input/output function. Use the clamp meter to measure the mA signal without disconnection and output the mA signal source. Apply the mA input signal to the device, and then measure its 4-20mA on the valve or mA isolator and other devices. output.
SACE PR121/P E3H32 Iu = 3200A
IC755CSS12CDB
SACE PR121/P E3H08 Iu = 800A
SACE PR331/P X1N10 In=1000A
6SL3210-1PH31-4AL0
MPM-B1151F-MJ72AA
6SL3130-7TE23-6AA3
DHH805
CACR-120-PD1VDS01
6ES7414-2XL07-0AB0
6DD1607-0CA1
DAPU100 3ASC25H204
6AV2124-0QC02-0AX1
EPOWER/2PH-250A/600V/230V
Parker PM1-5E1-XD5
DST1405
095U2B300BACAA100190
PM856K01
1756HP-TIME/B
1756HP-TIME
671288-01
667633-01
671566-01
6GK5778-1GY00-0AA0
MDX61B0040-5A3-4-00
IS220PAICH1B
LXM62DU60D21000
PARKER AR-20AE
4D1084.00-090
4C2000.01-110
4E0020.01.090 & 4E0011.01-090
MC07B0075-5A3-4-00
CC-PCF901
CC-PCNT02
CC-SCMB02
CC-PUIO31
MVI56E-MNETR
VIA0701D02F0000
VIA1002C02A0000
6GK5788-2FC00-0AA0
6AV7894-0HG32-0AC0
VIA0703D01A0000
BATCHFLUX 5500 C
6ES7417-4HT14-0AB0
142U3E305BACAA165240
6SL3130-7TE28-0AA3
6SL3225-0BE37-5AA0
6ES7515-2RM00-0AB0
6SL3130-1TE31-0AA0
6SE7032-7EB87-2DA1
6AV2124-0JC01-0AX0
1KHL178025R0002
IC755CSS12CDB