SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹¥i±½Í
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹¥i±½Í
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹¥i±½Í
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹»ù®æ
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹§Þ³N°Ñ¼Æ
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹À³¥Î®×¨Ò
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹«~µP¤¶²Ð
SACE PR121/P E3H08¼Ò¶ôÂ_¸ô¾¹¬ÛÃö«H®§
¤@¡BSACE PR121/Pªº°ò¥»±¡ªp
SACE PR121/P¬OABBÂ_¸ô¾¹ªº«OÅ@¼Ò¶ô¡A¨ã¦³¥H¤U¯SÂI¡G
¤£¦PÃþ«¬¡GPR121/P¬°°ò¥»«¬¡A¦¹¥~ÁÙ¦³PR122/P¡]²G´¹Åã¥Ü¡^¡BPR123/P¡]°ª¡P«¬¡^µ¥Ãþ«¬¡C
À³¥Î³õ´º¬ÛÃöªº³]©w¡G
¥i³]©w¬°OFF©Î¬Û¹q¬yªº50%¡B100%©Î200%¡AÀ³¥Î©óE1¡BE2¡BE3¡BE4/f¡BE6/f¡A¥H¤Î±a¥~³¡¤¤©Ê½u«OÅ@ªºE4©ME6¡C
¥i³]©w¬°OFF©Î¬Û¹q¬yªº50%¡AÀ³¥Î©óE4©ME6¡C
¤G¡B»PE3H08¬ÛÃöªº¥i¯à±¡ªp
¦bE3«Y¦C¤¤ªº±¡ªp¡GEmaxªÅ®ðÂ_¸ô¾¹¦@¦³¤»ºØ«¬¸¹¡GX1¡BE1¡BE2¡BE3¡BE4¤ÎE6¡C¦pªG³oùتºE3H08¬OEmax«Y¦C¤¤ªº¤@ºØ³W®æ¡A¨º»ò¦b©MSACE PR121/P°t¦X®É¡ASACE PR121/Pªº«OÅ@¥\¯à±N¹ïE3H08¼Ò¶ô°_¨ì«OÅ@§@¥Î¡A¨Ò¦p¦b¹L¸ü¡Bµu¸ôµ¥±¡ªp¤U¶i¦æ¦³®Äªº²æ¦©«OÅ@¡C
ÃB©w¹q¬yµ¥°Ñ¼ÆÃöÁp¡GÁöµM¨S¦³ª½±µ´£¤ÎE3H08»PSACE PR121/P²Õ¦X®É¨ãÅ骺ÃB©w¹q¬yµ¥°Ñ¼Æ¾A°t±¡ªp¡A¦ý®Ú¾ÚEmax«Y¦Cªº¤@¯ë±¡ªp¡A¨äÃB©w¹q¬y½d³ò¬O400A¦Ü6300A¡A¤£¦Pªº³W®æ¥i¯à·|®Ú¾Ú¹ê»Ú»Ý¨D·f°tSACE PR121/P«OÅ@¼Ò¶ô¨Óº¡¨¬¹q¸ôªº«OÅ@»Ý¨D¡A¤ñ¦p¦bÃB©w¹q¬y¬°800A¡]°²³]E3H08¤¤ªº08ªí¥Ü800A¬ÛÃö°Ñ¼Æ¡^µ¥±¡ªp¤U¡ASACE PR121/P¥i¥H«ö·Ó¨ä¹L¸üªø©µ®É¾ã©w¡B¿ï¾Ü©Êµu¸ôµu©µ®É¾ã©wµ¥¥\¯à¶i¦æ³]¸m¨Ó«O»Ù¹q¸ô¡P¥þ¡C
SACE PR121/P E3H08 module circuit breaker related information
1. Basic information of SACE PR121/P
SACE PR121/P is a protection module for ABB circuit breakers and has the following features:
Different types: PR121/P is the basic type, in addition there are PR122/P (liquid crystal display), PR123/P (advanced type) and other types.
Application scenario related settings:
Can be set to OFF or 50%, 100% or 200% of phase current, applied to E1, E2, E3, E4/f, E6/f, and E4 and E6 with external neutral protection.
Can be set to OFF or 50% of phase current, applied to E4 and E6.
2. Possible situations related to E3H08
In the E3 series: There are six models of Emax air circuit breakers: X1, E1, E2, E3, E4 and E6. If the E3H08 here is a specification in the Emax series, then when used in conjunction with SACE PR121/P, the protection function of SACE PR121/P will protect the E3H08 module, such as effective protection in the event of overload, short circuit, etc. Trip protection.
Correlation of parameters such as rated current: Although there is no direct mention of the specific adaptation of parameters such as rated current when the E3H08 is combined with SACE PR121/P, according to the general situation of the Emax series, its rated current range is 400A to 6300A. Different specifications may Will match SACE according to actual needs PR121/P protection module to meet the protection needs of the circuit. For example, when the rated current is 800A (assuming that 08 in E3H08 represents 800A related parameters), SACE PR121/P can be set according to its overload long delay, selective short circuit short Delay setting and other functions can be set to ensure circuit safety.
6SN1123-1AA00-0KA1
6SN1145-1BB00-0FA1
KT3250TV
3BHL000389P0104
HITACHI LYA100A
LYD000A
LYD105A
LYA220A
3BHE013299R0002
CDB02.1B-ET-EC-EC-NN-L3-L3-NN-NN-FW R911338665
CSB02.1B-ET-EC-NN-S4-NN-NN-FW R911338543
CSB02.1A-ET-EC-NN-L3-NN-NN-FW R911339883
HMS01.1N-W0054-A-07-NNNN R911295325
HMD01.1N-W0012-A-07-NNNN R911306439
CDB02.1B-ET-EC-EC-NN-S4-S4-NN-NN-FW R911338542
MVI56E-61850S
ARND-3119A
6SN1123-1AB00-0HA2
6AV7885-5AE10-1AA2
6ES7314-6EH04-0AB0
6DS1731-8RR
6ES7635-2EC02-0AE3
3BHB020538R0001
20BC260A0ANNACC0
MDX61B005-5A3-4-0T
6AV6645-0CA01-0AX0
05704-A-0144ÀN¥§³º¸
P0924WV
P0926GX
P0926GX FBM233
P0926GU FBM230
FDC280
FCP280
SGM7D-1AF7C52
6SE7033-5GJ84-1JC0
6SE7033-5GJ84-1JC2
6AV6644-0CB01-2AX0
6AV7885-0AA10-1AA2
6AV7843-0AF10-0CB0