SACE PR121/P E3H08Â_¸ô¾¹¥i§å»ù
SACE PR121/P E3H08Â_¸ô¾¹¥i§å»ù
SACE PR121/P E3H08Â_¸ô¾¹¥i§å»ù
SACE PR121/P E3H08Â_¸ô¾¹³W®æ
SACE PR121/P E3H08Â_¸ô¾¹»ù®æ
SACE PR121/P E3H08Â_¸ô¾¹§Þ³N°Ñ¼Æ
SACE PR121/P E3H08Â_¸ô¾¹À³¥Î®×¨Ò
¤@¡BÃö©óSACE PR121/P E3H08Â_¸ô¾¹ªº°ò¥»«H®§
¡]¤@¡^©ÒÄÝ«Y¦C¤Î®Ø¬[Â_¸ô¾¹¯S©Ê PR121/P E3H08
³o¬OABBªº®Ø¬[Â_¸ô¾¹¡AEmax«Y¦C®Ø¬[Â_¸ô¾¹¨ã¦³¤@¨Ç¦@¦Pªº¯S©Ê¡C¨Ò¦p¥þ«Y¦CÂ_¸ô¾¹¨ã¦³¦P°ª«×¤Î¦P²`«×ªº¯S©Ê¡A©â¥X¦¡¾A¦X¦w¸Ë¦b²`«×500mmªº°t¹q½L¤¤¡A¼e«×324mm¡]ÃB©w¹q¬y°ª¹F2000A¡^©â¥X¦¡Â_¸ô¾¹¥i¦w¸Ë¦b¹j¶¡¼e400mmªº°t¹q½L¤¤¡A³o¨Ç¤Ø¤o³]pºë¥©¡A¥i´À´«¦´ÁªºªÅ®ðÂ_¸ô¾¹¡C¨ä¾Þ§@¾÷ºcÄÝ©óÀx¯à«¬¡A¥i¥Î¹w¥ýÀx¯àªº¼u®¾Þ§@¡A¼u®Àx¯à¥i¤â°Ê¾Þ§@«e±ªº¤â¬`©Î§Q¥Î¾¦½ü¦¡¹q°Ê¾÷¹q°Ê¾Þ§@¡A¤À¹h¼u®¦b¦X¹h¾Þ§@®É¦Û°ÊÀx¯à¡C
¡]¤G¡^«OÅ@³æ¤¸¬ÛÃö PR121/P E3H08
±`°tªº«OÅ@³æ¤¸«¬¸¹¦³PR111¡BPR112¡BPR121¡BPR122¡BPR123µ¥¡ASACE PR121/P§@¬°«OÅ@³æ¤¸¡A¬°Â_¸ô¾¹´£¨Ñ«OÅ@¥\¯à¬ÛÃöªº¤ä«ù¡C
¤G¡B²£«~¥i¯à¨ã³Æªº©Ê¯à¯SÂI PR121/P E3H08
¡]¤@¡^¦w¡P©Ê¤è± PR121/P E3H08
¨¾Å@µ¥¯Å»P¾Þ§@¦w¡P©Ê PR121/P E3H08
¦³¦hºØ¤è¦¡½T«O¦w¡P©Ê¡A¦pÂdªùÃö³¬®É¥i·n¥XÂ_¸ô¾¹¡A¹ï¥~¨¾Å@µ¥¯Å¹FIP54¡AÁÙ±a¦³¦UºØ¤£¦P¦w¡PÂê©MÂù«µ´½t¡C¨Ò¦pabbªÅ®ðÂ_¸ô¾¹Emax E3H1600 SACE PR121/P - LSI¼·½X¦¡¤T¬q¤T·¥´N¨ã³Æ³o¼Ëªº¦w¡P©Ê«O»Ù¡AE3H08¥i¯à¤]¦³Ãþ¦üªº¦w¡P³]p«ä¸ô¡C
·¥¬Wµ²ºc¦w¡P©Ê PR121/P E3H08
³Ð·s©Êªº·¥¬Wµ²ºc³]p¡A¬J¯à½T«O¬Û½u¶¡¥H¤Î¬Û½u»P¤¤©Ê½u¤§¶¡§¹¥þµ´½t¡A¦Ó¥B¥i¥H¬d¬Ý·À©·«Ç©M¥DIJÀYªºª¬ºA¡A³o¹ï©óE3H08Â_¸ô¾¹¦b¹q¸ô¤¤ªº¦w¡Péw¹B¦æ¦³«n·N¸q¡C
¡]¤G¡^¥\¯à»P©Ê¯à°Ñ¼Æ¤è± PR121/P E3H08
ÃB©w¹q¬y»P¤ÀÂ_¯à¤O PR121/P E3H08
ÁöµM¨S¦³ª½±µ¬d¸ß¨ìE3H08ªºÃB©w¹q¬y»P¤ÀÂ_¯à¤O·Ç½T¼ÆÈ¡A¦ýEmax«Y¦CªºÃB©w¹q¬y½d³ò¬O400A¦Ü6300A¡A¤ÀÂ_¯à¤O¥Ñ42kA¦Ü150kA¡]380/415VAC¡^¡AE3H08ªº¬ÛÃö°Ñ¼Æ¥i¯à¦b³oÓ½d³ò¤º¡A¨Ã¥B¤£¦PªºÀ³¥Î³õ´º¥i¯à·|®Ú¾Ú»Ý¨D¶i¦æ¿ï«¬°t¸m¡C
´¼¯à¥\¯à PR121/P E3H08
´¼¯à«OÅ@²æ¦©¾¹°t¦³¥ý¶iªº¹q¤l¤¸¾¹¥ó¡A¥i¥H«×¨©w¨î¤£¦Pªº±±¨î©M«OÅ@¤è®×¡CÁ٨㦳·sªº«OÅ@¥\¯à©M³øĵ¥\¯à¡A¨Ã¥B¥i¯à¥i¥H³q¹LÂŤú§Þ³N³s±µ¨ì¥~³¡³]³Æ¡]¦p¤â´£¹q¸£/µ§°O¥»¹q¸£¡^¡A¤£¹L³o»Ýn®Ú¾Ú¨ãÅé²£«~°t¸m½T©w¡AE3H08¥i¯à¨ã³Æ³o¼Ëªº´¼¯à¤Æ¼ç¤O¡C
1. Basic information about SACE PR121/P E3H08 circuit breaker
(1) Series and frame circuit breaker characteristics
This is ABB's frame circuit breaker. The Emax series frame circuit breakers have some common characteristics. For example, the full series of circuit breakers have the same height and depth characteristics. The withdrawable type is suitable for installation in a switchboard with a depth of 500mm. The withdrawable circuit breaker with a width of 324mm (rated current up to 2000A) can be installed in a switchboard with a compartment width of 400mm. These dimensions Compact design to replace earlier air circuit breakers. Its operating mechanism is an energy storage type and can be operated by a pre-stored spring. The spring energy storage can be manually operated by the front handle or electrically operated by a gear motor. The opening spring automatically stores energy during the closing operation.
(2) Protection unit related
Commonly equipped protection unit models include PR111, PR112, PR121, PR122, PR123, etc. SACE PR121/P, as a protection unit, provides protection function-related support for circuit breakers.
2. Possible performance characteristics of the product
(1) Safety aspects
Protection level and operational safety
There are many ways to ensure safety, such as the circuit breaker that can be rolled out when the cabinet door is closed, the external protection level reaches IP54, and it also comes with various safety locks and double insulation. For example, abb air circuit breaker Emax E3H1600 SACE PR121/P - LSI dial-type three-stage three-pole has such safety guarantee, and E3H08 may have similar safety design ideas.
pole structural safety
The innovative pole structure design not only ensures complete insulation between phase lines and between phase lines and neutral lines, but also allows you to check the status of the arc extinguishing chamber and main contacts, which is important for the safety and stability of the E3H08 circuit breaker in the circuit. Operation is of great significance.
(2) Function and performance parameters
Rated current and breaking capacity
Although the exact rated current and breaking capacity of E3H08 are not directly available, the rated current range of the Emax series is 400A to 6300A, and the breaking capacity is from 42kA to 150kA (380/415VAC). The relevant parameters of E3H08 may be within this range, and Different application scenarios may require selection and configuration based on requirements.
Smart functions
The intelligent protection tripper is equipped with advanced electronic components and can tailor different control and protection schemes. It also has new protection functions and alarm functions, and may be able to connect to external devices (such as laptops/laptops) via Bluetooth technology, but this needs to be determined based on the specific product configuration. E3H08 may have such intelligence potential.
6FC5447-0AA00-0AA1
6FC5410-0AY01-0AA0
6SN1118-0NK01-0AA1
430ETH-IB 2730190
DCU305R3
20G1ANC140AA0NNNNN
PM866AK01
SK-20P-S5N18
6AV2124-0QC02-0AX1
6SE7090-0XX85-1DA0
6SE7031-2HG84-1JC2
A1A461D85.00M
10000432.30M
6SE7038-6GL84-1JA1
8536SDG1
KM531A
ABB PP877
A06B-6222-H026#H610
6SL3120-1TE31-3AA3
SGLC3606L4XX
57c430a
GMS600
UMC556000-03
E82EV752-4C200
MT4414TE-RO
6SE7417-5HT06-0AB0
5SHY4045L0006 3BHB030310R0001
3BHB012961R0001
6AV7886-0EA11-2AB0
ACS580-01-430A-4
CP-316H/215