SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô»ù®æ
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô§Þ³N°Ñ¼Æ
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ôÀ³¥Î®×¨Ò
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô«~µP¤¶²Ð
SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô
¤@¡B²£«~·§z PR331/P X1N10
SACE PR331/P¬O¤@ºØ¹q¤l²æ¦©¾¹¡A¥Î©ó»PX1N10µ¥Â_¸ô¾¹°t¦X¨Ï¥Î¡C³oºØ²Õ¦X¦bABBªº®Ø¬[Â_¸ô¾¹«Y¦C¤¤¨ã¦³¯S©wªº¥\¯à©MÀ³¥Î³õ´º¡A¥Dn¥Î©ó¹ï¹q¸ô¶i¦æ«OÅ@©M±±¨î¡C¥¦¯à°÷ºÊ´ú¹q¸ô¤¤ªº¹q¬y¡B¹qÀ£µ¥°Ñ¼Æ¡A·í¥X²{¹L¸ü¡Bµu¸ôµ¥²§±`±¡ªp®É¡A«ö·Ó³]©wªº²æ¦©¯S©Ê¨ÏÂ_¸ô¾¹°Ê§@¡A¤ÁÂ_¹q¸ô¡A«OÅ@³]³Æ©M½u¸ô¡P¥þ¡C
¤G¡B¥\¯à¯SÂI PR331/P X1N10
«OÅ@¥\¯à PR331/P X1N10
¹L¸ü«OÅ@¡G¯à°÷ÀË´ú¹q¸ô¤¤ªº¹q¬y¬O§_¶W¹LÃB©w¹q¬y¡C·í«ùÄò¹L¸ü®É¡ASACE PR331/P·|®Ú¾Ú³]©wªº¹L¸ü¦±½u¡AIJµoX1N10Â_¸ô¾¹°Ê§@¡AÁקK½u¸ô©M³]³Æ¦]ªø®É¶¡¹L¸ü¦Ó·lÃa¡C
µu¸ô«OÅ@¡G¦b¹q¸ôµo¥Íµu¸ô¬G»Ù®É¡AÀþ¶¡ÀË´ú¨ìµu¸ô¹q¬y¡A«P¨ÏÂ_¸ô¾¹¨³³t¤ÁÂ_¹q¸ô¡A¥H«OÅ@¾ãÓ¹q¤O«Y²Î¡C¨äµu¸ô«OÅ@ªºÅTÀ³³t«×§Ö¡A¥i¦³®Ä¨îµu¸ô¹q¬y¹ï³]³Æªº½ÄÀ»¡C
°Ñ¼Æ¥i³]©w©Ê PR331/P X1N10
¥i¥H³q¹L¬ÛÃöªº³]¸m±µ¤f¡]¦p¼·½X¶}Ãöµ¥¤è¦¡¡^¹ï«OÅ@°Ñ¼Æ¶i¦æ½Õ¾ã¡A¨Ò¦p³]©w¤£¦Pªº¹L¸ü¹q¬yìHÈ¡Bµu¸ô«OÅ@ªº°Ê§@®É¶¡µ¥¡A¥H¾AÀ³¤£¦Pªº¹q¸ô»Ý¨D¡C³o¨Ï±oSACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¯à°÷¦b¦hºØ¹q¤O«Y²ÎÀô¹Ò¤UÆF¬¡À³¥Î¡AµL½×¬O¤u·~¼t©Ð¡B°Ó·~«Ø¿vÁÙ¬O¨ä¥L¹q¤O³]¬Iªº°t¹q«Y²Î¡C
¤T¡BÀ³¥Î³õ´º PR331/P X1N10
¤u·~»â°ì PR331/P X1N10
¦b¤u¼tªº¥Í²£¨®¶¡¡A¦s¦b¤j¶qªº¹q°Ê¾÷¡B¾÷§Éµ¥³]³Æ¡CSACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥i¥Î©ó³o¨Ç³]³Æªº°t¹q½u¸ô«OÅ@¡C¨Ò¦p¡A·í¹q°Ê¾÷±Ò°Ê®É¥i¯à·|²£¥Í¸û¤jªº±Ò°Ê¹q¬y¡A¸Ó¼Ò¶ô¯à°÷°Ï¤À¥¿±`±Ò°Ê¹q¬y©M¬G»Ù¹q¬y¡A½T«O¹q°Ê¾÷¥¿±`±Ò°Êªº¦P®É¡A¦b¥X²{¬G»Ù®É¤Î®É«OÅ@¡C
°Ó·~«Ø¿v PR331/P X1N10
¦b°Ó³õ¡B¼g¦r¼Óµ¥³õ©Ò¡A¦³²³¦hªº·Ó©ú¡BªÅ½Õ¡B¹q±èµ¥¥Î¹q³]³Æ¡C¸ÓÂ_¸ô¾¹¼Ò¶ô¥i¦w¸Ë¦b¼Ó¼h°t¹q½c©ÎªÌÁ`°t¹q«Ç¡A¹ï¦U¤ä¸ô¹q¸ô¶i¦æ«OÅ@¡A¨¾¤î¦]¬Y¤@³]³Æ¬G»Ù¤Þµoªº¹q¸ô°ÝÃD¼vÅT¾ãÓ«Ø¿vªº¹q¤O¨ÑÀ³¡C
SACE PR331/P X1N10 circuit breaker module
1. Product Overview
SACE PR331/P is an electronic trip unit for use with circuit breakers such as X1N10. This combination has specific functions and application scenarios in ABB's frame circuit breaker series, and is mainly used to protect and control circuits. It can monitor the current, voltage and other parameters in the circuit. When abnormal conditions such as overload and short circuit occur, the circuit breaker will operate according to the set tripping characteristics, cut off the circuit, and protect the safety of the equipment and lines.
2. Functional features
protection function
Overload protection: Able to detect whether the current in the circuit exceeds the rated current. When overload continues, SACE PR331/P will trigger the X1N10 circuit breaker according to the set overload curve to avoid damage to lines and equipment due to long-term overload.
Short circuit protection: When a short circuit fault occurs in the circuit, the short circuit current is detected instantly, prompting the circuit breaker to quickly cut off the circuit to protect the entire power system. Its short-circuit protection has a fast response speed and can effectively limit the impact of short-circuit current on equipment.
Parameter configurability
Protection parameters can be adjusted through relevant setting interfaces (such as DIP switches, etc.), such as setting different overload current thresholds, short-circuit protection action times, etc., to adapt to different circuit needs. This enables the SACE PR331/P X1N10 circuit breaker module to be flexibly used in a variety of power system environments, whether it is the distribution system of industrial plants, commercial buildings or other power facilities.
3. Application scenarios
Industrial field
In the production workshop of the factory, there are a large number of motors, machine tools and other equipment. SACE PR331/P X1N10 circuit breaker modules can be used for distribution line protection of these devices. For example, when a motor starts, it may generate a large starting current. This module can distinguish between normal starting current and fault current, ensuring that the motor starts normally and provides timely protection in the event of a fault.
commercial building
In shopping malls, office buildings and other places, there are numerous lighting, air conditioning, elevators and other electrical equipment. The circuit breaker module can be installed in the floor distribution box or main distribution room to protect each branch circuit and prevent circuit problems caused by a certain equipment failure from affecting the power supply of the entire building.
SH31401P12F2000
SH140/30120/0/1/00/00/00/11/00
NS15-TX01B-V2
SCHNEIDER 13130266-001
20G1AND302JN0NNNNN
NGDR-07C
6ES7556-1AA00-0AB0
2UBA004416R0004
DST1402
MDX60A0750-503-4-00
MDX60A0300-503-4-00
3BHL000391P0101 5SHX1445H0001
ABB¨©§QTPSTU12-B
A06B-6240-H331
A06B-0428-B200#1002
396604-03-0
DME5000-111
DT500-A211
SJDE-08ANA
1395-B78-C4-P12-X1
DCS800-S02-0200-05-0
PM866AK02 3BSE081637R1
3BSE081636R1 PM862K02
3BSE069449R1 CI854BK01
CI867A
5SHY3545L0009 3BHB013085R0001
6ES5247?4UA21
PXI-1033
TBUX297247
GE 239-RTD-AN
ABB DSSB-01C 68300746
6AV6646-1AD22-0AX0
6AV7884-0AB10-3BA0
A02B-0259-C211
6AV7100-0AE11-1CC1
A06B-6400-H002