§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~³]³Æ
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~³]³Æ ¨ä¥¦ SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù 5

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥iij»ù

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô»ù®æ

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô§Þ³N°Ñ¼Æ

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ôÀ³¥Î®×¨Ò

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô«~µP¤¶²Ð

SACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô

¤@¡B²£«~·§­z PR331/P X1N10

SACE PR331/P¬O¤@ºØ¹q¤l²æ¦©¾¹¡A¥Î©ó»PX1N10µ¥Â_¸ô¾¹°t¦X¨Ï¥Î¡C³oºØ²Õ¦X¦bABBªº®Ø¬[Â_¸ô¾¹«Y¦C¤¤¨ã¦³¯S©wªº¥\¯à©MÀ³¥Î³õ´º¡A¥D­n¥Î©ó¹ï¹q¸ô¶i¦æ«OÅ@©M±±¨î¡C¥¦¯à°÷ºÊ´ú¹q¸ô¤¤ªº¹q¬y¡B¹qÀ£µ¥°Ñ¼Æ¡A·í¥X²{¹L¸ü¡Bµu¸ôµ¥²§±`±¡ªp®É¡A«ö·Ó³]©wªº²æ¦©¯S©Ê¨ÏÂ_¸ô¾¹°Ê§@¡A¤ÁÂ_¹q¸ô¡A«OÅ@³]³Æ©M½u¸ô¡P¥þ¡C

¤G¡B¥\¯à¯SÂI PR331/P X1N10

«OÅ@¥\¯à PR331/P X1N10

¹L¸ü«OÅ@¡G¯à°÷ÀË´ú¹q¸ô¤¤ªº¹q¬y¬O§_¶W¹LÃB©w¹q¬y¡C·í«ùÄò¹L¸ü®É¡ASACE PR331/P·|®Ú¾Ú³]©wªº¹L¸ü¦±½u¡AIJµoX1N10Â_¸ô¾¹°Ê§@¡AÁקK½u¸ô©M³]³Æ¦]ªø®É¶¡¹L¸ü¦Ó·lÃa¡C

µu¸ô«OÅ@¡G¦b¹q¸ôµo¥Íµu¸ô¬G»Ù®É¡AÀþ¶¡ÀË´ú¨ìµu¸ô¹q¬y¡A«P¨ÏÂ_¸ô¾¹¨³³t¤ÁÂ_¹q¸ô¡A¥H«OÅ@¾ã­Ó¹q¤O«Y²Î¡C¨äµu¸ô«OÅ@ªºÅTÀ³³t«×§Ö¡A¥i¦³®Ä­­¨îµu¸ô¹q¬y¹ï³]³Æªº½ÄÀ»¡C

°Ñ¼Æ¥i³]©w©Ê PR331/P X1N10

¥i¥H³q¹L¬ÛÃöªº³]¸m±µ¤f¡]¦p¼·½X¶}Ãöµ¥¤è¦¡¡^¹ï«OÅ@°Ñ¼Æ¶i¦æ½Õ¾ã¡A¨Ò¦p³]©w¤£¦Pªº¹L¸ü¹q¬yìH­È¡Bµu¸ô«OÅ@ªº°Ê§@®É¶¡µ¥¡A¥H¾AÀ³¤£¦Pªº¹q¸ô»Ý¨D¡C³o¨Ï±oSACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¯à°÷¦b¦hºØ¹q¤O«Y²ÎÀô¹Ò¤UÆF¬¡À³¥Î¡AµL½×¬O¤u·~¼t©Ð¡B°Ó·~«Ø¿vÁÙ¬O¨ä¥L¹q¤O³]¬Iªº°t¹q«Y²Î¡C

¤T¡BÀ³¥Î³õ´º PR331/P X1N10

¤u·~»â°ì PR331/P X1N10

¦b¤u¼tªº¥Í²£¨®¶¡¡A¦s¦b¤j¶qªº¹q°Ê¾÷¡B¾÷§Éµ¥³]³Æ¡CSACE PR331/P X1N10Â_¸ô¾¹¼Ò¶ô¥i¥Î©ó³o¨Ç³]³Æªº°t¹q½u¸ô«OÅ@¡C¨Ò¦p¡A·í¹q°Ê¾÷±Ò°Ê®É¥i¯à·|²£¥Í¸û¤jªº±Ò°Ê¹q¬y¡A¸Ó¼Ò¶ô¯à°÷°Ï¤À¥¿±`±Ò°Ê¹q¬y©M¬G»Ù¹q¬y¡A½T«O¹q°Ê¾÷¥¿±`±Ò°Êªº¦P®É¡A¦b¥X²{¬G»Ù®É¤Î®É«OÅ@¡C

°Ó·~«Ø¿v PR331/P X1N10

¦b°Ó³õ¡B¼g¦r¼Óµ¥³õ©Ò¡A¦³²³¦hªº·Ó©ú¡BªÅ½Õ¡B¹q±èµ¥¥Î¹q³]³Æ¡C¸ÓÂ_¸ô¾¹¼Ò¶ô¥i¦w¸Ë¦b¼Ó¼h°t¹q½c©ÎªÌÁ`°t¹q«Ç¡A¹ï¦U¤ä¸ô¹q¸ô¶i¦æ«OÅ@¡A¨¾¤î¦]¬Y¤@³]³Æ¬G»Ù¤Þµoªº¹q¸ô°ÝÃD¼vÅT¾ã­Ó«Ø¿vªº¹q¤O¨ÑÀ³¡C

SACE PR331/P X1N10 circuit breaker module

1. Product Overview

SACE PR331/P is an electronic trip unit for use with circuit breakers such as X1N10. This combination has specific functions and application scenarios in ABB's frame circuit breaker series, and is mainly used to protect and control circuits. It can monitor the current, voltage and other parameters in the circuit. When abnormal conditions such as overload and short circuit occur, the circuit breaker will operate according to the set tripping characteristics, cut off the circuit, and protect the safety of the equipment and lines.

2. Functional features

protection function

Overload protection: Able to detect whether the current in the circuit exceeds the rated current. When overload continues, SACE PR331/P will trigger the X1N10 circuit breaker according to the set overload curve to avoid damage to lines and equipment due to long-term overload.

Short circuit protection: When a short circuit fault occurs in the circuit, the short circuit current is detected instantly, prompting the circuit breaker to quickly cut off the circuit to protect the entire power system. Its short-circuit protection has a fast response speed and can effectively limit the impact of short-circuit current on equipment.

Parameter configurability

Protection parameters can be adjusted through relevant setting interfaces (such as DIP switches, etc.), such as setting different overload current thresholds, short-circuit protection action times, etc., to adapt to different circuit needs. This enables the SACE PR331/P X1N10 circuit breaker module to be flexibly used in a variety of power system environments, whether it is the distribution system of industrial plants, commercial buildings or other power facilities.

3. Application scenarios

Industrial field

In the production workshop of the factory, there are a large number of motors, machine tools and other equipment. SACE PR331/P X1N10 circuit breaker modules can be used for distribution line protection of these devices. For example, when a motor starts, it may generate a large starting current. This module can distinguish between normal starting current and fault current, ensuring that the motor starts normally and provides timely protection in the event of a fault.

commercial building

In shopping malls, office buildings and other places, there are numerous lighting, air conditioning, elevators and other electrical equipment. The circuit breaker module can be installed in the floor distribution box or main distribution room to protect each branch circuit and prevent circuit problems caused by a certain equipment failure from affecting the power supply of the entire building.

SH31401P12F2000

SH140/30120/0/1/00/00/00/11/00

NS15-TX01B-V2

SCHNEIDER 13130266-001

20G1AND302JN0NNNNN

NGDR-07C

6ES7556-1AA00-0AB0

2UBA004416R0004

DST1402

MDX60A0750-503-4-00

MDX60A0300-503-4-00

3BHL000391P0101 5SHX1445H0001

ABB¨©§QTPSTU12-B

A06B-6240-H331

A06B-0428-B200#1002

396604-03-0

DME5000-111

DT500-A211

SJDE-08ANA

1395-B78-C4-P12-X1

DCS800-S02-0200-05-0

PM866AK02 3BSE081637R1

3BSE081636R1 PM862K02

3BSE069449R1 CI854BK01

CI867A

5SHY3545L0009 3BHB013085R0001

6ES5247?4UA21

PXI-1033

TBUX297247

GE 239-RTD-AN

ABB DSSB-01C 68300746

6AV6646-1AD22-0AX0

6AV7884-0AB10-3BA0

A02B-0259-C211

6AV7100-0AE11-1CC1

A06B-6400-H002


Áp«Y¤è¦¡
  • Áp«Y¤H¡G ³¯¤u ¤k¤h
  • ¹q¸Ü¡G 0592-6083550
  • ¶Ç ¯u¡G 0592-6083550
  • ¤â¾÷¡G 18030206773
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« ·Hªù¥«®ü·É°Ï®õ¦a®ü¦è1803
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H