6SL3210-1PH31-4AL0¥\²v¼Ò¶ô¥i±»ù
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô¥i±»ù
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô¥i±»ù
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô»ù®æ
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô´ë¹D
6SL3210-1PH31-4AL0¥\²v¼Ò¶ôÀ³¥Î®×¨Ò
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô¸Ô²Ó°Ñ¼Æ
6SL3210-1PH31-4AL0¥\²v¼Ò¶ô
1¡B²£«~³W®æ 6SL3210-1PH31-4AL0
¥\²v¯S©Ê¡G 6SL3210-1PH31-4AL0
«¹L¸ü¥\²v¤è±¡A¦b200% 3S¡A150% 57S¡A100% 240S¥BÀô¹Ò·Å«×-20¦Ü +50¢XC(HO)®É¬°110kW¡F¦b¥\²v»´¹L¸ü±¡ªp¤U¡A·í150% 3S¡A110% 57S¡A100% 240S¥BÀô¹Ò·Å«×-20¦Ü +40¢XC(LO)®É¬°132kW¡C
¹q®ð°Ñ¼Æ¡G¤u§@¹qÀ£¬°500-690V+10/-20%¤T¬Û¥æ¬y¡AÀW²v½d³ò¬O47-63Hz¡C
ª«²z¤Ø¤o¡G¤Ø¤o¬°708x305x357(°ªx¼ex²`)¡A¨¾Å@µ¥¯Å¹F¨ìIP20¡A¨Ã¥B¤£±a±±¨î³æ¤¸©M¾Þ§@³æ¤¸¡C
2.¬G»Ù±Æ¬d¡]°w¹ï¥]§t¸Ó¼Ò¶ôªº¦èªù¤lÅÜÀW¾¹¡^6SL3210-1PH31-4AL0
°ò©ó³øĵ«H®§±Æ¬d¡G·í³]³Æ¥X²{¬G»Ù®É¡Aº¥ý¬d¬ÝÅÜÀW¾¹¤W¼Æ½XºÞÅã¥Üªº³øĵ«H®§¡A®Ú¾Ú³øĵ»¡©ú±Æ¬d¬G»Ù¡C
¸U¥Îªí´ú¶q±Æ¬d¡G6SL3210-1PH31-4AL0
ª½±µÀˬd¬G»ÙÅÜÀW¾¹®É¡A¤W¹qÀˬd¶}©ln¥Î¸U¥Îªí´ú¶q¡C±N¸U¥Îªí¥´¨ì1Kªº¹qªýÀÉ¡A¶Âªíµ§»PÅÜÀW¾¹ª½¬y(-)·¥³s±µ¡A¬õªíµ§³s±µ¤T¶µ¿é¤J¡B¿é¥XºÝ´ú¶q¹qªý¡A¥¿±`¹qªýȦb5 - 10K¤§¶¡¡A¥B¿é¤J¡B¿é¥X¤T¬Û¤§¶¡n¤@P¡A¿é¥XºÝ¤T¬Û¹qªýȲ¤¤p©ó¿é¤J¹qªýÈ¡C
¦b§¹¦¨(-)´ú¹qªý´ú¶q«á¡A±N¶Âªíµ§©ñ¦b(+)´úÄ~Äò¤T¬Û´ú¶q¡A¤èªk¬Û¦P¡CY¹qªýÈ¥¿±`¥BµL¥R©ñ¹q²{¶H¡A«h¥i¶i¦æ¤W¹q´ú¶q¡F§_«h¥i¯à¥\²v³¡¥ó·lÃa¡AY¦³©úÅã¿N·´²ª¸ñ«h¤£¯àª½±µ¤W¹q¡An§ó´«°ÝÃD³¡¥ó¡C
6SL3210-1PH31-4AL0 power module
1. Product specifications
Power characteristics:
In terms of heavy overload power, it is 110kW at 200% 3S, 150% 57S, 100% 240S and the ambient temperature is -20 to +50¢XC (HO); under light overload power, when 150% 3S, 110% 57S, 132kW at 100% 240S and ambient temperature -20 to +40¢XC (LO).
Electrical parameters: Working voltage is 500-690V+10/-20% three-phase AC, frequency range is 47-63Hz.
Physical dimensions: Dimensions are 708x305x357 (height x width x depth), protection level reaches IP20, and without control unit and operating unit.
2. Troubleshooting (for Siemens inverters containing this module)
Troubleshooting based on alarm information: When the equipment fails, first check the alarm information displayed on the digital tube on the inverter, and troubleshoot the fault according to the alarm description.
Multimeter measurement troubleshooting:
When directly checking the faulty inverter, use a multimeter to measure it at the beginning of the power-on check. Set the multimeter to the resistance level of 1K, connect the black test lead to the DC (-) pole of the inverter, and connect the red test lead to the three input and output terminals to measure the resistance. The normal resistance value is between 5 and 10K, and the input and output three-phase should be consistent, and the three-phase resistance value at the output end should be slightly smaller than the input resistance value.
After completing the (-) resistance measurement, place the black test lead on the (+) measurement to continue the three-phase measurement with the same method. If the resistance value is normal and there is no charging or discharging phenomenon, the power-on measurement can be performed; otherwise, the power component may be damaged. If there are obvious burn marks, the power cannot be directly turned on, and the problem component must be replaced.
NOVELLUS 19-00127-00
6PPT30.101G-20B
AH465207U002
A5E01649325
9468/33-08-10
9470/33-16-10
9477/15-08-12
SRM64-HZZ0-S03
XC-CPU201-EC256K-8DI-6DO
1C31194G03
140CPU67160S
LMS111-10100
GDM120N-528/0750
MOD600ARTD4
PLX51-PBM
9440/15-01-11-C1198
9468/32-08-11
F6214
F6215
EN-208-00-000
XD-02-MSD0
8V1090-00-2
6SE7041-8EK85-0HA0
6AV7881-3AE00-8CA0
FH-5050-10
SDCS-PIN-H01
6SE7026-0TP60-Z Z=G91+K80
SXWTBASW110002
0811405157
Fluke Ti480
Fluke 1775
Fluke 1625-2
Fluke 1630-2
Fluke 810
Fluke 773
eaton 58868-400
ACS800-01-0120-5
A06B-6250-H045