§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~³]³Æ
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~³]³Æ ¨ä¥¦ CE55NN3A¤Ï¦V±µÄ²¾¹¥iij»ù 6

CE55NN3A¤Ï¦V±µÄ²¾¹¥iij»ù

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

CE55NN3A¤Ï¦V±µÄ²¾¹¥iij»ù

CE55NN3A¤Ï¦V±µÄ²¾¹¥iij»ù

CE55NN3A¤Ï¦V±µÄ²¾¹¥iij»ù

CE55NN3A ¤Ï¦V±µÄ²¾¹ªº¤u§@­ì²z

CE55NN3A ¤Ï¦V±µÄ²¾¹ªº¥«³õ»ù®æ

CE55NN3A ¤Ï¦V±µÄ²¾¹ªº«~µP¹ï¤ñ

CE55NN3A ¤Ï¦V±µÄ²¾¹ªº¦w¸Ë»PºûÅ@

CE55NN3A ¤Ï¦V±µÄ²¾¹ªº±`¨£¬G»Ù¤Î¸Ñ¨M¤èªk

CE55NN3A¤Ï¦V±µÄ²¾¹¬ÛÃö«H®§

²£«~·§­z

CE55NN3A¤Ï¦V±µÄ²¾¹¬O¤@ºØ¤u·~¥Î³~ªº¥æ¬y±µÄ²¾¹¡A¥D­n¥Î©ó±±¨î¹q°Ê¾÷©M¨ä¥L¹q®ð³]³Æªº¥¿¤ÏÂà¾Þ§@¡C¨ä¥D­n¥\¯à¬O³q¹L§ïÅܹq¸ô¤¤ªº¹q¬y¤è¦V¨Ó¹ê²{³]³Æªº¤Ï¦V¹BÂà¡A¼sªxÀ³¥Î©ó¤u·~¦Û°Ê¤Æ¡B§Mª÷¡B³y¯È¡BÄq¤s¡B¥Û¤Æµ¥¦h­Ó»â°ì¡C

¤u§@­ì²z

¤Ï¦V±µÄ²¾¹ªº¤u§@­ì²z°ò©ó¹qºÏ§l¦X§@¥Î¡C·í½u°é³q¹q®É¡A²£¥ÍªººÏ³õ§l¤ÞIJÀY³¬¦X¡A±q¦Ó¹ê²{¹q¸ôªº³s±µ¡F·í½u°éÂ_¹q®É¡AIJÀY¦b¼u®¤Oªº§@¥Î¤U¤ÀÂ÷¡A¤ÁÂ_¹q¸ô¡C³q¹L±±¨î½u°éªº³qÂ_¡A¥i¥H¹ê²{¹q¸ôªº¥¿¦V©Î¤Ï¦V³s±µ¡C

À³¥Î³õ´º

CE55NN3A¤Ï¦V±µÄ²¾¹¼sªxÀ³¥Î©ó¥H¤U³õ´º¡G

¹q°Ê¾÷±±¨î¡G¥Î©ó±±¨î¹q°Ê¾÷ªº¥¿¤ÏÂà¡A¹ê²{¾÷±ñ³]³Æªº¥¿¤ÏÂà¾Þ§@¡C

¦Û°Ê¤Æ¥Í²£½u¡G¦b¦Û°Ê¤Æ¥Í²£½u¤W¡A³q¹L±±¨î¹q°Ê¾÷ªº¥¿¤ÏÂà¡A¥i¥H¹ê²{¤u¥óªº¦Û°Ê½Âà©M¿é°e¡C

§Mª÷¦æ·~¡G¦b§Mª÷¦æ·~¤¤¡A¤Ï¦V±µÄ²¾¹¥Î©ó±±¨îªî¾÷ªº¥¿¤ÏÂà¡A´£°ª¥Í²£®Ä²v¡C

³y¯È¦æ·~¡G¦b³y¯È¦æ·~¤¤¡A¤Ï¦V±µÄ²¾¹¥Î©ó±±¨î¨÷¯È¾÷ªº¥¿¤ÏÂà¡A¹ê²{¯È±iªº¦Û°Ê¨÷¨ú¡C

§Þ³N°Ñ¼Æ

ÃB©w¹qÀ£»P¹q¬y

ÃB©w¹qÀ£¡G24V¦Ü220V¤£µ¥¡A¨ãÅé¨ú¨M©óÀ³¥Î»Ý¨D¡C

ÃB©w¹q¬y¡G®Ú¾Ú¨ãÅ髬¸¹©MÀ³¥Î³õ´º¦³©Ò¤£¦P¡A±`¨£ªº¦³60A¡B100Aµ¥¡C

·¥¼Æ»PIJÂI§Î¦¡

·¥¼Æ¡G¤@¯ë¬°3·¥©Î4·¥¡A¾A¥Î©ó¤£¦Pªº¹q®ð±±¨î»Ý¨D¡C

IJÂI§Î¦¡¡G±`¶}¥DIJÀY¼Æ¶q©M±`³¬»²§UIJÀY¼Æ¶q¦]«¬¸¹¦Ó²§¡A³q±`°t¦³¦hºØÄ²ÂI°t¸m¥Hº¡¨¬¤£¦P¹q¸ô³s±µ»Ý¨D¡C

¤u§@Àô¹Ò·Å«×»P®ü©Þ°ª«×

¤u§@Àô¹Ò·Å«×¡G³q±`¦b-20¢XC¦Ü50¢XC¤§¶¡¡A³¡¤À«¬¸¹¥i¾AÀ³§ó°ª·Å«×Àô¹Ò¡C

¤u§@®ü©Þ°ª«×¡G¤@¯ë¥i¦b®ü©Þ1000¦Ì¥H¤UªºÀô¹Ò¤¤¨Ï¥Î¡C

CE55NN3A reverse contactor related information

Product overview

The CE55NN3A reverse contactor is an AC contactor for industrial use, mainly used to control the forward and reverse operations of motors and other electrical equipment. Its main function is to realize the reverse operation of the equipment by changing the direction of current in the circuit. It is widely used in industrial automation, metallurgy, papermaking, mining, petrochemical and other fields.

Working principle

The working principle of the reverse contactor is based on electromagnetic attraction. When the coil is energized, the generated magnetic field attracts the contacts to close, thereby connecting the circuit; when the coil is deenergized, the contacts separate under the action of the spring force, cutting off the circuit. By controlling the on and off of the coil, the forward or reverse connection of the circuit can be achieved.

Application scenarios

CE55NN3A reverse contactor is widely used in the following scenarios:

Motor control: used to control the forward and reverse rotation of the motor to achieve forward and reverse rotation of mechanical equipment.

Automated production line: In an automated production line, by controlling the forward and reverse rotation of the motor, the workpiece can be automatically turned over and transported.

Metallurgical industry: In the metallurgical industry, reverse contactors are used to control the forward and reverse rotation of rolling mills to improve production efficiency.

Papermaking industry: In the papermaking industry, the reverse contactor is used to control the forward and reverse rotation of the paper winding machine to realize automatic winding of paper.

Technical parameters

Rated voltage and current

Rated voltage: 24V to 220V, depending on application requirements.

Rated current: It varies according to the specific model and application scenarios. Common ones are 60A, 100A, etc.

Number of poles and contact form

Number of poles: Generally 3 poles or 4 poles, suitable for different electrical control needs.

Contact form: The number of normally open main contacts and normally closed auxiliary contacts varies depending on the model, and is usually equipped with a variety of contact configurations to meet different circuit connection needs.

Working environment temperature and altitude

Working environment temperature: usually between -20¢XC and 50¢XC, some models can adapt to higher temperature environments.

Working altitude: Generally it can be used in environments below 1,000 meters above sea level.

SST-PB3-CLX-RLL

6DL3100-8AC05

XV C722 3BHB002751R0102

6AV7241-3XB07-0FA0

PMM13.3-A288

PMC-35.2-003

E82MV551-4B151

3HAC026611-001/00

3BHE021889R0101

GEUX30-1000-001

JGDR-G1C

XV-440-10TVB-1-10

16F5CBE-YA00

6177R-MMAW7

TRICONEX 3664

TRICONEX 3721

CPU-8055 Power-M

AXES 8055 VPP

I/O 8055

APBU-44CE

MC07B0750-503-4-00

MC07B0300-503-4-00

MC07B0055-5A3-4-00/FSC11B

IS220PPDAH1B

AE16NN0A

CE55NN3A

C6920-0060

AKD-P02407-NBEC-000

6SE7021-0TP60

GEÂù¹q·½±±¨î­±ªOMX150

3BHE006805R0001

EPALM10-DA71

MDS-DH-CV-550

HMP-HM64

EVS9323-ES

C500-NC103

6AV7468-0FA11-0BS0

CM50/1E0S0E0/STD

CM50/0E0S0E0/STD

07-7331-2307

07-7331-2304/0000

07-7331-2302/0000

1756-CNBR    3   31378

1756-L61  3    63900

¬I­@¼wÅÜÀW¾¹    ATV960C50Q4X1    1»O

1769-HSC   25¦~­±»ù¡G12310   1

1769-IF4   25¦~­±»ù¡G6702   1

DCF1061142R0001

YT204001-AM ¦U1

EDK82MV752

¬ì«ÂIJºN«Ì    HK-B-070-BX-E    2

¬ì«ÂPLC¥D¾÷    LP2-14M12R    2

¬ì«ÂPLC¥D¾÷¥d¥ó    EX1-2AD2DA    2

EH10-AI-001    2

BOSCH SF-A1.0016.060-10.050 1070919392   1

420-2AD31-1CA1   1

F650BABF1G0HIC   1­Ó

P3-16TR

P3-EX

P3-11B

P3-FILL

P3-RTB

P3-16DA-1

P3-08AD

P3-01DC

P3-EX-CBL6

P3-16ND3

GJR2397000R1210¼Æ¶q2

GIR2391500R1210¼Æ¶q8

6SL3055-0AA00-2CA0    1

S0854931   1

700G08 5740700G08 5740

C63N32D630    ¼Æ¶q8

BMH0702P17F2A   ¼Æ¶q1

PM2100   ¼Æ¶q2

214-1AG31-0XB0      1

D2-BAT-1  2

PS-PGMSW 1

EA-SD-Card 1

EA9-T15CL-R

8250-749   1

8273-1011   1

DST-162     1

1756-IF8IH   2 ­±»ù37852

1756-OW16I   2 ­±»ù8996

2711P-T12W22D9P   4  ­±»ù49858

Áp«Y¤è¦¡
  • Áp«Y¤H¡G ¤p«C ¤k¤h
  • ¾¦ì¡G ¸g²z
  • ¶Ç ¯u¡G 0592-6535181
  • ¹q¸Ü¡G 0592-7796135
  • ¤â¾÷¡G 18020768791
  • ¦a §}¡G ºÖ«Ø¬Ù ·Hªù¥« ®ü·É°Ï·É´òªF¤@ùØ508¸¹502
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H
  • 01
  • §Ö³tµo¥¬¨DÁÊ«H®§
  • ¤U¤@¨B
  • 03
  • Áp«Ycnal«ÈªA¡G
  • ­P¹q¡G 0371-63388900
    °¨¤W±Ò°Ê±zªº§Ö³t±ÄÁʳq¹D¡I