«~µP¡G¼w¤O | ³W®æ¡GUN1-25 |
UN1«Y¦C¹qªý¹ï²k¾÷
¹qªý¹ï²k¾÷ªº¥Dn²k±µ¤uÃÀ¤Î¬Û¹ïÀuÂI¡G
1.¹qªý¹ï²k¾÷¬O±N¨â¤u¥óºÝ±©l²×À£ºò¡A§Q¥Î¹qªý¼ö±N±µÄ²³¡¤À¥[¼ö¦Ü¶ì©Êª¬ºA¡AµM«á¨³³t¬I¥[³»ÁëÀ£¤O©Î¤£¥[³»ÁëÀ£¤O¥u«O«ù²k±µÀ£¤O¡A¨Ó§¹¦¨²k±µªº¤èªk¡C
2.»P°{¥ú¹ï²k¬Û¤ñ¡A¹qªý¹ï²k¾Þ§@²³æ¡A»ù®æ«K©y¡A²k±µ®Ä²v°ª¡C
3.²k±µ«á±µÀY¥ú·Æ¡A¤ò¨ë¤p¡C
4.µ²ºc³]pºë¥©¡A¹ï¤£¤@ªº¤u¥ó²k±µ®e©ö½Õ¾ã,ªº¹ï²k¾÷±±¨î¹q¸ô¡A½T«O²k±µ½è¶q¡C
5.¥Dn¥Î©ó¹ï²kºI±¿n¤p©ó250mmªºª÷ÄÝ«¬§÷¡A¦pÅK½u¡AºÞ§÷µ¥µ¥¡C
¥Dn§Þ³N°Ñ¼Æ¡G
°Ñ¼Æ Parameter | ÃB©w®e¶q Rated Capacity | ÃB©w¿é¤J¹qÀ£ Rated Input Voltage | ÃB©wÀW²v Rated Frequency | ¤jµu¸ô¹q¬y Max Short Current | t¸ü«ùÄò²v Rated Duty Cycle | ¤j§¨ºò¤O Max Clamping Force | ¤j³»Áë¤O Max Upsetting Force | §N«o¤ô¬y¶qCooling Water Required | ¥~§Î¤Ø¤oOver Dimensions L*W*H | ¥§¡«¶q Average Weight |
«¬¸¹ Model No. | ||||||||||
UN1-25 | 25KVA | 380V | 50/60Hz | 11000A | 50% | 3900N | 1500N | 150L/H | 90*80*120CM | 300Kg |
UN1-35 | 35KVA | 380V | 50/60Hz | 15000A | 50% | 3900N | 1500N | 150L/H | 90*80*120CM | 350Kg |
UN1-50 | 50KVA | 380V | 50/60Hz | 19000A | 50% | 3900N | 1500N | 150L/H | 90*80*120CM | 400Kg |
UN1-75 | 75KVA | 380V | 50/60Hz | 23500A | 50% | 6100N | 2500N | 200L/H | 90*80*120CM | 450Kg |
UN1-100 | 100KVA | 380V | 50/60Hz | 26000A | 50% | 6100N | 2500N | 200L/H | 90*80*120CM | 500Kg |
UN1-150 | 150KVA | 380V | 50/60Hz | 31000A | 50% | 8000N | 3900N | 300L/H | 135*80*160CM | 550Kg |
UN1-200 | 200KVA | 380V | 50/60Hz | 35000A | 50% | 8000N | 3900N | 300L/H | 135*80*160CM | 650Kg |