1/4õX½u¹qÆl HCAHY(Z)-50-6 1/4RF Cable

µ²ºc¤Îµ²ºc¤Ø¤o Structure and dimensions
¤º¾ÉÅé »É Inner Conductor Copper
¥~¾ÉÅé »É Outer Conductor Copper
¤º¾ÉÅé¼ÐºÙª½®| 2.6 mm O.D. of Inner Conductor ¡]normal¡^
¥~¾ÉÅé¼ÐºÙª½®| 7.7

1/4¡²õX½u¹qÆl HCAHY(Z)-50-6     1/4¡²RF Cable

µ²ºc¤Îµ²ºc¤Ø¤o
Structure and dimensions
¤º¾ÉÅé                               »É
Inner Conductor                      Copper
¥~¾ÉÅé                               »É
Outer Conductor                      Copper
¤º¾ÉÅé¼ÐºÙª½®|                      2.6 mm
O.D. of Inner Conductor ¡]normal¡^
¥~¾ÉÅé¼ÐºÙª½®|                      7.7 mm
O.D. of Outer Conductor ¡]normal¡^
Å@®M¼ÐºÙª½®|                        8.7 mm
O.D. of Jacket ¡]normal¡^
¹qÆl°Ñ¦Ò­«¶q                       0.10 kg/m
Cable weight
¾÷±ñ©Ê¯à
Mechanical Properties
¤pÅs¦±¥b®|                       80 mm
Minimum Bending Radius
¤pÅs¦±¦¸¼Æ                       15
Number of Bends,  Min.
§Ü©Ô¤O                             14 kg
Tensile strength
¹q®ð©Ê¯à
Electrical properties
¼ÐºÙ¯S©Êªý§Ü                       50 W
Normal Impedance
°ª¤u§@ÀW²v                       15.8 GHz
Maximum Frequency
¶Ç¿é³t¤ñ                           86 %
Velocity Ratio
®p­È¥\²v                           13.2 kw
Peak Power Rating
®p­È¹qÀ£                           1.15 kv
Peak Voltage
¼ÐºÙ¹q®e                           77 pF/m
Normal Capacitance
¤º¾ÉÅé¤jª½¬y¹qªý                3.57 W/km
D.C. Resistance of Inner Conductor
¥~¾ÉÅé¤jª½¬y¹qªý                3.66 W/km
D.C. Resistance of Outer Conductor
¤pµ´½t¹qªý                     3000 MW¡Pkm
Minimum Insulation Resistance
µ´½t¤¶¹q±j«×                       2000 v
D.C. Breakdown
Å@®M¤õªá¸ÕÅç¹qÀ£                   3000 v
Jacket Spark
¦w¸Ë¤ÎÀô¹Ò©Ê¯à
Installation and Environment Properties
±ÀÂË/¤j¦w¸Ë¥d¶Z                  0.3m / 0.3m
Recommend /Max. Clamp Space
¦w¸Ë·Å«×                          -200C~+600C
Temperature for installing
Àx¦s¤Î¤u§@·Å«×                    -450C~+850C
Temperature for Storage & operating
 

°I´î©M¥­§¡¥\²v
Attenuation and Average Power
ÀW²v     °I´î(¼ÐºÙ­È/¤j­È)       ¥­§¡¥\²v
Frequency   Attenuation (normal/max.)   Average Power               
MHz            dB/100m             kw
150            4.91 / 5.50             1.60
800           12.10 / 13.55            0.64
900           12.99 / 14.47            0.60
1000          13.78 / 15.44            0.57
1700          18.67 / 20.92            0.43
1800          19.31 / 21.45            0.41
1900          19.93 / 22.33            0.40
2000          20.54 / 22.80            0.39
2200          21.72 / 24.33            0.37
2300          22.30 / 24.98            0.36
ª`¡G¥H¤W°I´î­È¨Ì¾ÚYD/T 1092-2004¡A¸g¨Ñ»ÝÂù¤è¨ó°Ó¥i¾A·í½Õ¾ã¡C
Note: The maximum attenuation above is according to YD/T 1092-2004, it can be adjusted after both-side permitted.
 

¥]¸Ë­n¨D
Packing Requirements
¦¨½L¥]¸Ë
Packing by Reels
·í¹qÆlªø«×¶W¹L300m®É±Ä¥Î¥þ¤ì½L©Î½¦¦X¼hªO½L¥]¸Ë¡C¥]¸Ë½L¥~§Î¤Ø¤o¨£ªí1¡C
The wood or plywood reels will be used, when the length of cable is more than 300m. The dimensions of these reels are shown in the following table 1.
ªí1 ¥]¸Ë½L¥~§Î¤Ø¤o ¡]Table 1  Dimensions of reels¡^


½L¨ã«¬¸¹
Reel Type
°¼ªOª½®|
Flange dia.(mm)
¤j¥~¼e
Max. Width (mm)
C

C

 
¯È½c¥]¸Ë
Packing by Paper Boxes
·í¹qÆlªø«×¤£¶W¹L300m®É±Ä¥Î¯È½c¥]¸Ë¡C¯È½c¥~§Î¤Ø¤o¨£ªí2¡C
The paper boxes will be used, when the length of cable isn¡¦t  more than 300m. The dimensions of these boxes are shown in the following table 2.
ªí2 ¯È½c¥~§Î¤Ø¤o ¡]Table 1  Dimensions of paper boxes¡^

½L¨ã«¬¸¹
Reel Type
ªø
Length (mm)
¼e
Width (mm)
°ª
High  (mm)
CB


CB



Áp«Y¤è¦¡
  • Áp«Y¤H¡G ³¯¥ÉªL ¥ý¥Í
  • ¾¦ì¡G ¾P°â³¡¸g²z
  • ¶Ç ¯u¡G 0550-7513889
  • ¹q¸Ü¡G 0550-7313889
  • ¤â¾÷¡G 13625509884
  • ¦a §}¡G ¦wÀ²¬Ù ÞQ¦{¥« ¦wÀ²ÞQ¦{¤Ñªø¥«¤j³qÂíÅò¥Ðµó¹D
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H