²£¦a¡Ganhjiehao |
1/4õX½u¹qÆl HCAHY(Z)-50-6 1/4RF Cable
µ²ºc¤Îµ²ºc¤Ø¤o Structure and dimensions
¤º¾ÉÅé »É Inner Conductor Copper
¥~¾ÉÅé »É Outer Conductor Copper
¤º¾ÉÅé¼ÐºÙª½®| 2.6 mm O.D. of Inner Conductor ¡]normal¡^
¥~¾ÉÅé¼ÐºÙª½®| 7.7
1/4¡²õX½u¹qÆl HCAHY(Z)-50-6 1/4¡²RF Cable
µ²ºc¤Îµ²ºc¤Ø¤o
Structure and dimensions
¤º¾ÉÅé »É
Inner Conductor Copper
¥~¾ÉÅé »É
Outer Conductor Copper
¤º¾ÉÅé¼ÐºÙª½®| 2.6 mm
O.D. of Inner Conductor ¡]normal¡^
¥~¾ÉÅé¼ÐºÙª½®| 7.7 mm
O.D. of Outer Conductor ¡]normal¡^
Å@®M¼ÐºÙª½®| 8.7 mm
O.D. of Jacket ¡]normal¡^
¹qÆl°Ñ¦Ò«¶q 0.10 kg/m
Cable weight
¾÷±ñ©Ê¯à
Mechanical Properties
¤pÅs¦±¥b®| 80 mm
Minimum Bending Radius
¤pÅs¦±¦¸¼Æ 15
Number of Bends, Min.
§Ü©Ô¤O 14 kg
Tensile strength
¹q®ð©Ê¯à
Electrical properties
¼ÐºÙ¯S©Êªý§Ü 50 W
Normal Impedance
°ª¤u§@ÀW²v 15.8 GHz
Maximum Frequency
¶Ç¿é³t¤ñ 86 %
Velocity Ratio
®pÈ¥\²v 13.2 kw
Peak Power Rating
®pȹqÀ£ 1.15 kv
Peak Voltage
¼ÐºÙ¹q®e 77 pF/m
Normal Capacitance
¤º¾ÉÅé¤jª½¬y¹qªý 3.57 W/km
D.C. Resistance of Inner Conductor
¥~¾ÉÅé¤jª½¬y¹qªý 3.66 W/km
D.C. Resistance of Outer Conductor
¤pµ´½t¹qªý 3000 MW¡Pkm
Minimum Insulation Resistance
µ´½t¤¶¹q±j«× 2000 v
D.C. Breakdown
Å@®M¤õªá¸ÕÅç¹qÀ£ 3000 v
Jacket Spark
¦w¸Ë¤ÎÀô¹Ò©Ê¯à
Installation and Environment Properties
±ÀÂË/¤j¦w¸Ë¥d¶Z 0.3m / 0.3m
Recommend /Max. Clamp Space
¦w¸Ë·Å«× -200C~+600C
Temperature for installing
Àx¦s¤Î¤u§@·Å«× -450C~+850C
Temperature for Storage & operating
°I´î©M¥§¡¥\²v
Attenuation and Average Power
ÀW²v °I´î(¼ÐºÙÈ/¤jÈ) ¥§¡¥\²v
Frequency Attenuation (normal/max.) Average Power
MHz dB/100m kw
150 4.91 / 5.50 1.60
800 12.10 / 13.55 0.64
900 12.99 / 14.47 0.60
1000 13.78 / 15.44 0.57
1700 18.67 / 20.92 0.43
1800 19.31 / 21.45 0.41
1900 19.93 / 22.33 0.40
2000 20.54 / 22.80 0.39
2200 21.72 / 24.33 0.37
2300 22.30 / 24.98 0.36
ª`¡G¥H¤W°I´îȨ̾ÚYD/T 1092-2004¡A¸g¨Ñ»ÝÂù¤è¨ó°Ó¥i¾A·í½Õ¾ã¡C
Note: The maximum attenuation above is according to YD/T 1092-2004, it can be adjusted after both-side permitted.
¥]¸Ën¨D
Packing Requirements
¦¨½L¥]¸Ë
Packing by Reels
·í¹qÆlªø«×¶W¹L300m®É±Ä¥Î¥þ¤ì½L©Î½¦¦X¼hªO½L¥]¸Ë¡C¥]¸Ë½L¥~§Î¤Ø¤o¨£ªí1¡C
The wood or plywood reels will be used, when the length of cable is more than 300m. The dimensions of these reels are shown in the following table 1.
ªí1 ¥]¸Ë½L¥~§Î¤Ø¤o ¡]Table 1 Dimensions of reels¡^
½L¨ã«¬¸¹ Reel Type | °¼ªOª½®| Flange dia.(mm) | ¤j¥~¼e Max. Width (mm) |
C | ||
C |
¯È½c¥]¸Ë
Packing by Paper Boxes
·í¹qÆlªø«×¤£¶W¹L300m®É±Ä¥Î¯È½c¥]¸Ë¡C¯È½c¥~§Î¤Ø¤o¨£ªí2¡C
The paper boxes will be used, when the length of cable isn¡¦t more than 300m. The dimensions of these boxes are shown in the following table 2.
ªí2 ¯È½c¥~§Î¤Ø¤o ¡]Table 1 Dimensions of paper boxes¡^
½L¨ã«¬¸¹ Reel Type | ªø Length (mm) | ¼e Width (mm) | °ª High (mm) |
CB | |||
CB |