§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ­ì®Æ¤Î»²®Æ ·ÑÄq¥Îªý¿U¾ó®M³n¹qÆl«¬¸¹¤Î°Ñ¼Æ ´¶³q·|­û

·ÑÄq¥Îªý¿U¾ó®M³n¹qÆl«¬¸¹¤Î°Ñ¼Æ

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§
²£¦a¡Ganhjiehao

²£«~¥Î³~¡G²£«~¨Ñ·ÑÄq²¾°Ê¹q¾¹³]³Æ¤Î±Ä±¸¾÷±ñ°t®M¥Î¡C

Scope of application:The product necessary uses for the coal mine migration electric appliance equipment and the excavation machinery

°õ¦æ¼Ð·Ç Standards implemented: MT 818-1999

«¬¸¹¦WºÙ Model descriptions

«¬ ¸¹
  Model

¦W ºÙ
  Descriptions

MY

·ÑÄq¥Î²¾°Ê¾ó®M³n¹qÆl
  Mobile rubber soft cables for mines

MYQ

·ÑÄq¥Î²¾°Ê»´«¬¾ó®M³n¹qÆl
  Mobile light type rubber soft cables for mines

MYP

·ÑÄq¥Î²¾°Ê«Ì½ª¾ó®M³n¹qÆl
  Mobile shielded rubber soft cables for mines

MC

±Ä·Ñ¾÷¾ó®M³n¹qÆl
  Rubber soft cables for coal cutter in mines

MCP

±Ä·Ñ¾÷«Ì½ª¾ó®M³n¹qÆl
  Shielded rubber soft cables for coal cutter in mines

MZ

·ÑÄq¥Î¹qÆp
  Electric drill rubber cables for mines

MZP

·ÑÄq¥Î¹qÆp«Ì½ª¾ó®M¹qÆl
  Electric drill shielded rubber cables for mines

¨Ï¥Î¯S©Ê

Service characteristics

«¬ ¸¹
  Model

MYQ MZ MZP MY MYP MC MCP

ÃB©w¹qÀ£
  U0/U Rated voltage

0.3/0.5kv 0.38/0.66kv 0.66/1.14kv

¹qÆlªø´Á¤¹³\¤u§@·Å«×
  Long-term service temperature of the cable conductor

65¢J

¹qÆlªºzui¤pÅs¦±¥b®|
  Minimun bending radius

6D

¹qÆl³W®æ Specifications

«¬ ¸¹
  Model

ªä ¼Æ
  Core number

ÃB©w¹qÀ£ KV
  Rated voltage

¼ÐºÙºI­±mm2
  Nominal sectional

°Ê¤O½uªä
  Core for power

¦a½uªä
  Core for ground

±±¨î½uªä
  Pilot wire core

MY

1

0.38/0.66

50-150

-

-

3+1

3x4-3x70

1x4-1x25

-

MZ MZP

3+1¡B3+1+1

0.3/0.5

3X2.5-3X4

1X2.5-1X4

1X2.5-1X4

MYQ

2¡B3¡B4¡B7¡B12

0.3/0.5

1.0-2.5

-

-

3+1

3X1.0-3X2.5

1X0.75-1X1.5

MC

3+1+3

0.38/0.66

3x16-3x50

1x4-1x10

3x2.5-3x4

MCP

3+1+3

0.38/0.66

3x16-3x50

1x4-1x10

3x2.5-3x4

0.66/1.14

3x35-3x95

1x6-1x25

MYP

3+1

0.38/0.66

3x4-3x70

1x4-1x25

-

0.66/1.14

3x10-3x95

1x10-1x25

 

¹qÆl¥D­n§Þ³N©Ê¯à

Major technical performances

1¡B ¹qÆl¾ÉÅ骽¬y¹qªý

DC resistance of the conductor

«¬ ¸¹
  Model

¼ÐºÙºI­±
  Nominal sectional
 
¡]mm2¡^

200C®É¾ÉÅ骽¬y¹qªý¡] £[/Km¡^
  DC resistance of the conductor at 20
¢J

«¬ ¸¹
  Model

¼ÐºÙºI­±
  Nominal sectional
 
¡]mm2¡^

200C®É¾ÉÅ骽¬y¹qªý¡] £[/Km¡^
  DC resistance of the conductor at 20
¢J

¤£Áá¿ü
  Untinned

Áá¿ü
  Tinned

¤£Áá¿ü
  Untinned

Áá¿ü
  Tinned

MYQ

1.0

19.5

20.0

MY
  MYP

10

1.91

1.95

1.5

13.3

13.7

16

1.21

1.24

2.5

7.98

8.21

25

0.780

0.795

MZ
  MZP

2.5

-

8.82

35

0.554

0.565

4

-

5.39

50

0.386

0.393

MC
  MCP

4

-

5.09

70

0.272

0.277

6

-

3.39

95

0.206

0.210

10

-

1.95

120

0.161

0.164

16

-

1.24

150

0.129

0.132

25

-

0.795

185

0.106

0.108

35

-

0.565

240

0.0801

0.0817

50

-

0.393

300

0.0641

0.0654

MY
  MYP

4

4.95

5.09

400

0.0485

0.0495

6

3.30

3.39

-

-

-

2¡B ¹qÆlªºµ´½t¹qªý Dielectric resistance

«¬ ¸¹
  Model

°Ê¤O½uªä¼ÐºÙºI­±mm2
  Core for power nominal sectional

20¢J®Éµ´½t¹qªý
 
¡] M£[ Km¡^
  Dielectric resistance at 20
¢J

«¬ ¸¹
  Model

°Ê¤O½uªä¼ÐºÙºI­±mm2
  Core for power nominal sectional

20¢J®Éµ´½t¹qªý¡] M£[ Km¡^
  Dielectric resistance at 20
¢J

MYQ

1.0

160

MY

MYP

10

160

1.5

160

16

120

2.5

160

25

120

MZ
  MZP

2.5

160

35

100

4

160

50

100

MC
  MCP

16

120

70

80

25

120

95

80

35

100

120

50

50

100

150

50

70

80

185

50

95

80

240

50

­­¨î½uªäControl core

100

300

50

MY
  MYP

4

200

400

50

6

180

-

-

3¡B¹qÆl¨ä¥¦¥D­n§Þ³N©Ê¯à Other major technical performances

¡]«¬ ¸¹ Model:MY MYP MYQ MC MCP MZ MZP¡^

§Ç ¸¹
  Serial number

¶µ ¥Ø
  Items

§Þ³N©Ê¯à
  Technical performances

1

½uªäª½¬y¹qªý¡] £[/Km¡^
  Core DC resistance

¨£¤Wªí
  See above table

2

µ´½t¹qªý¡] M£[ Km¡^
  Insulating resistance

¨£¤Wªí
  See above table

3

5min¤uÀW¹qÀ£¸ÕÅç
  5min power frequency voltage experiment

0.66/1.14

3.7KV¤uÀW¹qÀ£µ´½t¤£À»¬ï
  3.7KV power frequency voltage insulation does not penetrate

0.38/0.66

3KV¤uÀW¹qÀ£µ´½t¤£À»¬ï
  3KV power frequency voltage insulation does not penetrate

0.3/0.5

2KV¤uÀW¹qÀ£µ´½t¤£À»¬ï
  2KV power frequency voltage insulation does not penetrate

±±¨î½uªäControl core

1.5KV¤uÀW¹qÀ£µ´½t¤£À»¬ï
  1.5KV power frequency voltage insulation does not penetrate

4

¼ö©µ¦ù¸ÕÅç
  The heat extends the experiment

175%

5

³æ®Ú««ª½¿U¿N¸ÕÅç
  Single wire burning test

MT386

6

¦¨§ô¿U¿N¸ÕÅç
  Group burning test

zui¤j½uªäºI­±¿n¦b50mm2¤Î¥H¤W®É ²Å¦XAÃþ¦¨§ô¿U¿N¸ÕÅç­n¨D
  Max. core sectional area more than 50mm2conforms A kind group burning test

7

zui¤j½uªäºI­±¿n¦b50mm2¤Î¥H¤U®É ²Å¦XBÃþ¦¨§ô¿U¿N¸ÕÅç­n¨D
  Max. core sectional area more than 50mm2conforms B kind group burning

 


Áp«Y¤è¦¡
  • Áp«Y¤H¡G ³¯¥ÉªL ¥ý¥Í
  • ¾¦ì¡G ¾P°â³¡¸g²z
  • ¶Ç ¯u¡G 0550-7513889
  • ¹q¸Ü¡G 0550-7313889
  • ¤â¾÷¡G 13625509884
  • ¦a §}¡G ¦wÀ²¬Ù ÞQ¦{¥« ¦wÀ²ÞQ¦{¤Ñªø¥«¤j³qÂíÅò¥Ðµó¹D
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H