¾÷¬[3500/05-01-02-05-00-01 ¹q·½3500/15-05-05-05
¾÷¬[3500/05-01-02-05-00-01 ¹q·½3500/15-05-05-05
3500¾÷±ñ«OÅ@«Y²ÎÅã¥Ü¾¹
±a¦³±m¦âIJºN«Ì©M I/O ¼Ò¶ôªº3500 /94M VGA IJºN«ÌÅã¥Ü ¼Ò¶ô¥i¦b¾÷¾¹©Î±±¨î«ÇÅã¥Ü«nªº 3500 ¼Æ¾Ú¡CVGA ¨ã¦³ 3500 Ó®¶°Ê¯Å§O¡B«Y²Î©Mĵ³ø¨Æ¥ó¦Cªí¥H¤Î¼Ò¶ô¡B³q¹D©Mĵ³ø¼Æ¾Ú¥H¤Î¤EÓ¦Û©w¸qÅã¥Ü¿ï¶µ¡C¥Î©ó Direct¡B1X¡BGap ©Mĵ³øªº¹w¸m¡§¦Û©w¸q¡¨«Ì¹õµL»Ý°t¸m¡A¨Ï³]¸mÅܱo²³æ¡C¦³ 2 ºØ¤Ø¤o¥i¨Ñ¿ï¾Ü¡]10 ^¤o©M 15 ^¤o¡^¡A±z¥i¥H¦b¤@»OÅã¥Ü¾¹¤W¬d¬Ý¦h¹F¥|Ó¿W¥ß 3500 ¾÷¬[ªº¼Æ¾Ú¡CÅã¥Ü¼Ò¶ô¤]¦³¦w¸Ë¿ï¶µ¡A¥]¬A»ÇÃ즡©MÂê©w¦¡±³¡¦w¸Ë¡C¦MÀI°Ï°ì»{ÃÒ¥i¥Î©óÅã¥Ü¾¹¡C
¥»¯S§Q3500/25Áä¬Û¾¹¼Ò¶ô¤W¤@Ó¥b°ª«×¡BÂù³q¹D¼Ò¶ô¡A¸Ó¼Ò¶ô¥Î©óµ¹3500®Ø¬[ªººÊ´ú¼Ò¶ô´£¨ÑÁä¬Û«H¸¹¡C³oÓ¼Ò¶ô±µ¦¬¨Ó¦Û¹q´õ¬y¶Ç·P¾¹©ÎªÌ¹qºÏ¶Ç·P¾¹ªº¿é¤J«H¸¹¡A¨Ã¥B±N¸Ó«H¸¹Âà´«¬°¼Æ¦rÁä¬Û«H¸¹¡A¸Ó«H¸¹¦b·í¶b¤WªºÁä¬Û¦ì¼Ð°O¦bÁä¬Û¶Ç·P±´ÀY¤§¤U®É«ü¥Ü¥X¨Ó¡C3500ºÊ´ú«Y²Î¥i¥H±µ¦¬4ÓÁä¬Û«H¸¹¡C¨CÓÁä¬Û«H¸¹³£¬O¤@ӼƦr¦P¨B«H¸¹¯ß½Ä¡B¥Î©óºÊ´ú¼Ò¶ô©M¥~³¡¶EÂ_³]³Æ´ú¶q¥Ú¶q°Ñ¼Æ½Ñ¦p1X¿ÀW®¶´T©M¬Û¦ì¡C
²£«~¸Ô±¡¸ê®Æ¡G
PA³]³Æªº°t¸m±qControl Builder Mªº¨¤«×¨Ó¬Ý¡APROFIBUS PA³]³Æ»PPROFIBUS DP³]³ÆÃþ¦ü¡C¨CÓPA³]³Æ³£»Ýn¦³¤@Óµw¥ó©w¸q¤å¥ó¤~¯à¦bPROFIBUS¤W¶i¦æ°t¸m¡C¦ý¦Ò¼{¨ä¥L°t¸m¤è±¡A¥HÀò±o¾A·íªº¤uµ{³]p¡C³q¹LÃì±µ³]³ÆLD 800P©MSK3³s±µPA³]³Æ¥Ñ©óPA¨Ï¥Î»PDP¤£¦Pªº¶Ç¿é§Þ³N¡APA³]³ÆµLªkª½±µ³s±µ¨ìPROFIBUS DP¡C¨Ï¥Î³s±µ¸Ë¸m¡CÃì±µ³]³ÆLD 800P©MSK3¬OPROFIBUS DP©MPROFIBUS-PA¤§¶¡ªº±µ¤f¡CLD 800P©MSK3¬°³z©úºôÃö¡CPA³]³Æ³Qµø¬°PROFIBUS DP¤WªºDP³]³Æ¡CLD 800P©MSK3¤ä«ùPROFIBUS DP±q9.6 kbit/s¨ì12 Mbit/sªº©Ò¦³©w¸qªi¯S²v¡C
²£«~^¤å¸Ô±¡¸ê®Æ¡G
Configuration of PA-Devices From Control Builder M point of view PROFIBUS PA-devices are seen like PROFIBUS DP-devices. Every PA-device needs to have a hardware definition file to get it configured on PROFIBUS. But additional configuration aspects have to be taken into account to get a proper engineering. Connecting PA-Devices via Linking Device LD 800P and SK3 Due to the fact that PA is using a different transmission technology than DP, PAdevices cannot be connected directly to PROFIBUS DP. A linking device has to be used. The Linking Device LD 800P and SK3 is the interface between PROFIBUS DP and PROFIBUS PA. The LD 800P and SK3 is a transparent gateway. PA devices are seen as DP devices on the PROFIBUS DP. The LD 800P and SK3 supports all defined baudrates for PROFIBUS DP from 9.6 kbit/s up to 12 Mbit/s.
HONEYWELL | MC-PDIY22 80363972-150 | GE | IS200EROCH1A |
Honeywell | MC-PAOY22 80363969-150 | GE | IS200ERIOH1A IS200ERIOH1AAA |
HONEYWELL | MC-PAIH03 51304754-150 | GE | IS200ERDDH1A IS200ERDDH1ABA |
HONEYWELL | MC-IOLX02 51304419-150 | GE | IS200EPSMG2A IS200EPSMG2ADC |
Honeywell | MC-IOLX02 51304419-150 | GE | IS200EPCTG1A |
HONEYWELL | FC-USI-0002 | GE | IS200ECTBG2A |
HONEYWELL | FC-TSHART-1620M | GE | IC755CSW07CDA |
HONEYWELL | FC-TSAI-1620M | GE | IC755CSW07CDA |
HONEYWELL | FC-TPSU-2430 | GE | IC755CSS15CDA |
HONEYWELL | FC-SDO-0824 V1.3 | GE | IC755CSS12CDB |
§K³dÁn©ú¡G
AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C