BENTLY NEVADA 133323-01 MODÁ`½uRS-485 I/O¼Ò¶ô
BENTLY NEVADA 133323-01 MODÁ`½uRS-485 I/O¼Ò¶ô
²£«~¸Ô±¡¸ê®Æ¡G
¤T³q¹D¶W³t«OÅ@«Y²Î´£¨Ñ3Ó¿W¥ßªºÂà³tºÊ´ú³q¹D¡C¦b³øĵ®É¡A¤T³q¹D¶W³t«OÅ@«Y²Î¥i²ÕºA¦¨¯à´£¨Ñ3¿ï2ªºªí¨M¥\¯à¡C¨ã¦³³oºØ¥\¯à®É¡A¨Ó¦Û¨CÓ¼Ò¶ôªº³øĵ¿é¥X¶i¦æ¤ñ¸û¡A¦bÄ~¹q¾¹³QÅX°Ê«e¡A¨âÓ¼Ò¶ô¤@P¡C
133388-01 3500/53 ¶W³tÀË´ú¼Ò¶ô
133396-01 ¶W³tÀË´úI/O ¼Ò¶ô
288062-01 3500/53M Overspeed Detection Module
323133-01 Overspeed Detection I/O Module
±`¥Î«¬¸¹
3500/50-01-00-01(288062-02,133442-01)
3500/50-02-00-01
3500/50-03-00-01
3500/32??4³q¹DÄ~¹q¾¹¼Ò¶ô?
3500/32 4?³q¹DÄ~¹q¾¹¼Ò¶ô¬O¤@Ó¥þ°ª«×ªº¼Ò¶ô¡A¥¦¥i´£¨Ñ¥|ÓÄ~¹q¾¹ªº¿é¥X¶q¡C¥ô¦ó¼Æ¶qªº4?³q¹DÄ~¹q¾¹¼Ò¶ô¡A³£¥i©ñ¸m¦b®Ø¬[±µ¤f¼Ò¶ô¥kÃ䪺¥ô¤@ӼѦìùØ¡C4?³q¹DÄ~¹q¾¹¼Ò¶ôªº¨CÓ¿é¥X³£¥i¥H¿W¥ß½sµ{¡A¥H°õ¦æ©Ò»Ýnªºªí¨MÅÞ¿è¡C??
¨CÓÀ³¥Î¦b4?³q¹DÄ~¹q¾¹¼Ò¶ô¤WªºÄ~¹q¾¹¡A³£¨ã¦³¡§³øĵÅX°ÊÅ޿表¡C¸Ó³øĵÅX°ÊÅÞ¿è¥i¥Î¡§»Pªù¡¨©M¡§©Îªù¡¨ÅÞ¿è½sµ{¡A¨Ã¥i§Q¥Î®Ø¬[¤¤ªº¥ô¦óºÊ´ú¾¹³q¹D©Î¥ô¦óºÊ´ú¾¹³q¹Dªº²Õ¦X©Ò´£¨Ñªº³øĵ¿é¤J(ĵ§i©Î¦MÀI)¡C¸Ó³øĵÅX°ÊÅÞ¿èÀ³¥Î®Ø¬[²ÕºA³n¥ó½sµ{¡A¥iº¡¨¬À³¥Î¤¤ªº¯S®í»Ýn¡C??
ª`·N:??»Ýn¤T«¼Ò¶ô¤¾¾l(TMR)ªº±¡ªp¤UÀ³¨Ï¥Î3500/34?TMR?Ä~¹q¾¹¼Ò¶ô¡C?
«e±ªOLED§t¸q¡G?
OK?LED¡]µo¥ú¤G·¥ºÞ¡^¡G¼Ò¶ô¤u§@¥¿±`®É°{«G??
TX/RX?LED¡G¥Î©ó¶Ç°e©M±µ¦¬¡A·í¸Ó¼Ò¶ô»P®Ø¬[¤¤¨ä¥¦¼Ò¶ô¶¡³q°T¥¿±`®É°{«G??
CH?ALARM?LED¡G·í¸ÓÄ~¹q¾¹³q¹D³B©ó³øĵª¬ºA®É°{«G??
²£«~^¤å¸Ô±¡¸ê®Æ¡G
The three channel overspeed protection system provides three independent speed monitoring channels. When giving an alarm, the three channel overspeed protection system can be configured to provide a voting function of 2 out of 3. When equipped with this function, the alarm outputs from each module are compared and the two modules are consistent before the relay is driven.
133388-01 3500/53 Overspeed Detection Module
133396-01 Overspeed detection I/O module
288062-01 3500/53M Overspeed Detection Module
323133-01 Overspeed Detection I/O Module
Common models
3500/50-01-00-01(288062-02,133442-01)
3500/50-02-00-01
3500/50-03-00-01
3500/32 4-Channel Relay Module
The 3500/32 4-channel relay module is a full height module that can provide the output of four relays. Any number of 4-channel relay modules can be placed in any slot on the right side of the frame interface module. Each output of the 4-channel relay module can be independently programmed to execute the required voting logic. ??
Each relay applied to a 4-channel relay module has an "alarm drive logic". The alarm drive logic can be programmed with "AND" and "OR" logic, and can use the alarm input (warning or danger) provided by any monitor channel or any combination of monitor channels in the frame. The alarm driven logic application framework configuration software programming can meet special needs in applications. ??
Note: When triple module redundancy (TMR) is required, the 3500/34 TMR relay module should be used. ?
Meaning of front panel LED:
OK LED: Flashes when the module is operating normally
TX/RX LED: used for transmission and reception, flashing when communication between this module and other modules in the frame is normal
CH ALARM LED: Flashes when the relay channel is in an alarm state
§K³dÁn©ú¡G
AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C
YOKOGAWA | EB401-10 S1 | ¤Ú»®°Ò | DIO280 |
YOKOGAWA | EB401-10 | ¤Ú»®°Ò | DIO280 |
YOKOGAWA | EA1*A | ¤Ú»®°Ò | DIO264 |
YOKOGAWA | CP451-10 S2 | ¤Ú»®°Ò | DIO248 |
YOKOGAWA | CP451-10 | ¤Ú»®°Ò | DIO232 |
YOKOGAWA | CP401-10 | ¤Ú»®°Ò | DIO216 |
YOKOGAWA | CP345 S1 | ¤Ú»®°Ò | DI232 |
YOKOGAWA | CP345 | ¤Ú»®°Ò | CM202 |
YOKOGAWA | AMN11 | ¤Ú»®°Ò | AIO288/1 |
YOKOGAWA | AMM52 S4 | ¤Ú»®°Ò | AIO288 |