·Hªùªü¦Ì±±§Þ³N¦³¤½¥q
§d¤u18030132585
ÀN¥§³º¸PKS¹q·½51199929-100
²£«~¸Ô±¡¸ê®Æ¡G
DCS«Y²Î¬O¤°»ò·N«ä¡HDCS¬O¤À¥¬¦¡±±¨î«Y²Îªº^¤åÁY¼g¡]Distributed Control System¡^¡A¦b°ê¤º¦Û±±¦æ·~¤SºÙ¤§¬°¶°´²±±¨î«Y²Î¡C¥¦¬O¤@ӥѹLµ{±±¨î¯Å©M¹Lµ{ºÊ±±¯Å²Õ¦¨ªº¥H³q«Hºôµ¸¬°¯Ã±aªº¦h¯Åpºâ¾÷«Y²Î¡Aºî¦X¤Fpºâ¾÷¡]Computer¡^¡B³q°T¡]Communication¡^¡BÅã¥Ü¡]CRT¡^©M±±¨î¡]Control¡^µ¥§Þ³N¡A¨ä°ò¥»«ä·Q¬O
¤À´²±±¨î
¶°¤¤¾Þ§@
¤À¯ÅºÞ²z
°t¸mÆF¬¡
²ÕºA¤è«K¡C
DCS«Y²Î¥Dn¦³²{³õ±±¨î¯¸¡]I/O¯¸¡^¡B¼Æ¾Ú³q°T«Y²Î¡B¤H¾÷±µ¤f³æ¤¸¡]¾Þ§@û¯¸OPS¡B¤uµ{®v¯¸ENS¡^¡B¾÷Âd¡B¹q·½µ¥²Õ¦¨¡C«Y²Î¨ã³Æ¶}©ñªºÅé«Yµ²ºc¡A¥i¥H´£¨Ñ¦h¼h¶}©ñ¼Æ¾Ú±µ¤f¡C
^¤å²£«~¸Ô²Ó«H®§
What does DCS system mean? DCS is the English abbreviation for Distributed Control System, also known as Distributed Control System in the domestic automation industry. It is a multi-level computer system composed of process control level and process monitoring level, connected by a communication network, which integrates technologies such as computer, communication, display, and control. Its basic idea is
decentralized control
Centralized operation
Hierarchical management
Flexible configuration
Convenient configuration.
The DCS system mainly consists of on-site control stations (I/O stations), data communication systems, human-machine interface units (operator station OPS, engineer station ENS), cabinets, power supplies, etc. The system has an open architecture and can provide multi-layer open data interfaces.
C300¹Lµ{±±¨î¾¹¹B¦æ¦b¸g²{³õ¨Ï¥ÎÅçÃÒªº¡B¨ã¦³½T©w©Ê¯SÂIªº±±¨î°õ¦æÀô¹Ò(CEE)®Ö¤ß³n¥ó¤W¡A¬°PlantCruise¥»O´£¨Ñ±j¤j¡B¥i¾aªº±±¨î¥\¯à¡CC300¬O±N³sÄò±±¨î¡BÅÞ¿è±±¨î¡B¶¶§Ç±±¨î©M§å¶q±±¨î¶°©ó¤@¨ªººò´ê¡B§C¦¨¥»ªº¨Î±±¨î¾¹¡A¼sªx¾A¥Î©ó¤u·~À³¥Î¡C±±¨î¥\¯à¥Ñ±±¨îºâªk®w´£¨Ñ¡A±±¨îºâªk®w¥Ñ³QºÙ¬°¥\¯à¶ô(FunctionBlocks)ªº¤j¶q¹Bºâ¼ÒªO©Òºc¦¨¡Cªº¹Ï§Î¤Æªº±±¨î²ÕºA¤u¨ãControl Builder¨Ï±o±±¨îµ¦²¤ªº¥Í¦¨©M²ÕºA·¥¨ä¤è«K¡CControI Builder¤£¶È¥Î©ó²ÕºA±±¨îµ¦²¤¡AÁÙ¥i¥H±N²ÕºA¦nªº±±¨îµ¦²¤¤U¸Ë¦Ü±±¨î¾¹¨Ã¶i¦æ¦b½uºÊ±±©M¦b½uקï¡C
¡´ ¥\¯à±j¤jªº±±¨î³B²z¾¹¼Ò¥ó¡A½Õ¸`©MÅÞ¿è±±¨î¤@Åé¤Æ¡A¤¾¾l°t¸m©Î«D¤¾¾l°t¸m¿ï¾Ü
¡´ 50²@¬í°ò¥»±±¨î°õ¦æÀô¹Ò
¡´ ¶°¦¨±M§QºâªkProfit Loop¡A¤ñ¶Ç²ÎPIDºâªk¡A¯à¦³®Ä´£°ª«Y²Îéw©Ê30%¥H¤W³]p·s¿oªº8«Y¦C¿é¤J/¿é¥X¤l«Y²Î
¡´ ²³æ¦a««ª½±µ½u¤è¦¡¡A´î¤Ö¹qÆl¸ô®|¤Î¤£¥²nªºÅs¦±¡A´£°ª±µ½u®Ä²v¡A¨CÂI±µ½u®É¶¡¥§¡´î¤Ö3¤ÀÄÁ
¡´ ¼Ò¶ô±Ä¥Î¡§««ª½¶É±×¦¡¡¨³]p¡A¼W±j´²¼ö©Ê¯à¡A©ö©ó±µ½u¡A¥B¸`¬ù30%¥H¤Wªº¦w¸ËªÅ¶¡
¡´ ¤ä«ùProfibus DP³q°T¡´ ¥i¿ï¤¾¾l°t¸m¡´ ¥i¿ïHART³q°T¶°¦¨
¡´ ¥i¿ï¨¾»GÒ\¼h
¡@ ÀN¥§³º¸PKS¹q·½51199929-100
·Hªùªü¦Ì±±§Þ³N¦³¤½¥q¾ã¦X¤F¤u·~¦Û°Ê¤Æ»â°ìªº²³¦h«~µP
¡» Invensys Triconex
¡» Westinghouse¡]¦è«Î¡^
¡» Rockwell Allen-Bradley ¡]ù§J³º¸¡^
¡» Schneider Modicon¡]¬I@¼w²ö}±d¡^
¡» ABB ¸§Q®ú ·RÀq¥Í
¡» ¥»¯S§Q3500«Y¦CºÊ´ú«Y²Î¥d/«e¸m¾¹/¶Ç·P¾¹
¡» Motorola¡]¼¯¦«Ã¹©Ô¡^
¡» XYCOM
¡» GE FANUC(GEµo¨º¬ì)
¡» Yaskawa¡]¦w¤t¡^
¡» Bosch Rexroth¡]³Õ¥@¤O¤h¼Ö¡^
§K³dÁn©ú¡G
AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C
EMERSON | PR6424/010-110 CON021 | PROSOFT | MVI56-ADM |
¥»¯S§Q | PR6424/010-040 CON021 | PROSOFT | MVI46-MCM |
EPRO | PR6424/010-010-CN CON021 | PROSOFT | 5205-DFNT-PDPS |
EPRO | PR6424/010-010 CON021 | EMERSON | KJ4001X1-CA1 12P0623X062 |
EMERSON | PR6424/010-000 CON021 | EMERSON | KJ4001X1-CC1 12P0733X032 |
EPRO | PR6424/010-000 CON021 | EMERSON | KJ4001X1-CC1 12P0733X042 |
EPRO | PR6424/006-030 | EMERSON | KJ4001X1-CC1 12P0733X042 |
EMERSON | PR6424/000-140 CON021 | EMERSON | KJ4001X1-CG1 12P1812X042 |
EMERSON | PR6424/000-140 CON021 | EMERSON | KJ4001X1-CH1 12P1811X032 |