§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T«¬§÷ DOºÝ¤lªOMC-TDOY22 51204162 4

DOºÝ¤lªOMC-TDOY22 51204162

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

·Hªùªü¦Ì±±§Þ³N¦³­­¤½¥q

  DOºÝ¤lªOMC-TDOY22 51204162-175 51304337-150

                                               ²£«~¸Ô±¡¸ê®Æ¡G

±µ½u

1¡B µw¥ó³]³Æ¤§¶¡ªº³s±µ

³oºØ³s±µ¦b±±¨î«Ç¤º³¡¶i¦æ¡A¤j¦h±Ä¥Î¦hªä«Ì½ªÂùµ±½u©Î¦P¶b¹qÆl¡A¥Î¼Ð·Ç¤Æªº´¡¥ó´¡±µ¡C

³o¨Ç¹qÆlºÙ¬°«Y²Î¹qÆl¡AºØÃþ¦h¡A©Ò¥H¤u§@®É­n¥J²Ó¡BÂÔ·V¡A¤£¯à´¡¿ù¡A¨Ã°µ¦nÀˬd¤u§@¡C

2¡B DCS«Y²Î©M¦b½u»öªíªº³s±µ

³o¬O±±¨î«Ç»P²{³õ»öªíªº³s±µ¡A¶q¤jÂI¦h¡A¤@¯ë·|¦³¨âºØ§Î¦¡¡G

l  ¤@®Ú¹qÆl±qÀY¨ì©³¡A¤]´N¬O²{³õ»öªí©Î°õ¦æ¾÷ºcªº¨âªä¹qÆlª½±µ³s¨ì±±¨î«ÇDCS«Y²Î¬ÛÀ³ªº¼Ò¥ó±µ½uºÝ¤l¡F

l  ±±¨î«Ç³q¹L¦hªä¥D¹qÆl³s±µ¨ì²{³õÂI¶°¤¤ªº¦a¤è¡A³q¹L±µ½u²°¦A¤À§O¥Î¨âªä¹qÆl»P¨C­Ó²{³õ»öªí©Î°õ¦æ¾÷ºc³s±µ¡C

¥Ñ©ó±µ½uÂI¼Æ¸û¦h¡A¨C­ÓÂI·Ç½TµL»~¡A¨c©T¥i¾a¡A±Æ¦C¾ã»ô¡B¬üÆ[¡C

¹q·½

DCS«Y²Î¹q·½­n¨D«Ü°ª¡A¹q·½¥i¾a¥B¡F


³q±`±Ä¥ÎÂù¦^¸ô¨Ñ¹q¡A¦Û°Ê¤Á´«¡F

¸U¤@¨â¸ô³£°±¹q¡AÁÙ­n¦³¤£¶¡Â_¹q·½¡]UPS¡^Àþ®É±µ¤W¡A¥H«O«Y²Î¹B¦æ¦bª¬ºA¡C

DCS«Y²Î°t¸m¥]§t

¥æ´«¾÷

ºôµ¸¥´¦L¾÷¡A

¤uµ{®v¯¸¡A

¾Þ§@­û¯¸¡A

±±¨î¾¹¨¾¤õùÙ¡A

¼Æ¾Ú®wªA°È¾¹¡A

¦ê¤fªA°È¾¹¡C

C300±±¨î¾¹

¨ãÅé¾Þ§@­û¯¸¡A¤uµ{®v¯¸µ¥°t¸m·|®Ú¾Ú¹ê»Ú±¡ªp¦³©Ò¥X¤J¡C

«Y²ÎºûÅ@

­^¤å²£«~¸Ô²Ó«H®§

connection

1. Connection between hardware devices

This kind of connection is carried out in the control room, most of which are multi-core shielded twisted pair or coaxial cables, and are plugged with standardized plug-ins.

These cables are called system cables and have a variety of types, so when working, it is necessary to be careful and cautious, not to plug them in incorrectly, and to do a good job of inspection.

2. Connection between DCS system and online instruments

This is the connection between the control room and on-site instruments, which has a large quantity and usually comes in two forms:

A cable is connected from the beginning to the bottom, that is, the two core cable of the on-site instrument or actuator is directly connected to the corresponding module wiring terminal of the DCS system in the control room;

The control room is connected to a centralized location on site through a multi-core main cable, and then connected to each on-site instrument or actuator through a junction box using two core cables.

Due to the large number of wiring points, each point is accurate and reliable, arranged neatly and aesthetically pleasing.

Power Supply

The DCS system has high requirements for power supply, which is reliable and reliable;

Usually using dual circuit power supply, automatic switching;

One or two circuits are all powered off, and there is also an uninterrupted power supply (UPS) that is momentarily connected to ensure that the system operates in a state.

DCS system configuration includes

Switch

Network printer,

Engineer Station,

Operator station,

Controller firewall,

Database server,

Serial server.

C300 controller

The specific configuration of operator stations, engineer stations, etc. may vary depending on the actual situation.

system maintenance

C300¹Lµ{±±¨î¾¹¹B¦æ¦b¸g²{³õ¨Ï¥ÎÅçÃÒªº¡B¨ã¦³½T©w©Ê¯SÂIªº±±¨î°õ¦æÀô¹Ò(CEE)®Ö¤ß³n¥ó¤W¡A¬°PlantCruise¥­»O´£¨Ñ±j¤j¡B¥i¾aªº±±¨î¥\¯à¡CC300¬O±N³sÄò±±¨î¡BÅÞ¿è±±¨î¡B¶¶§Ç±±¨î©M§å¶q±±¨î¶°©ó¤@¨­ªººò´ê¡B§C¦¨¥»ªº¨Î±±¨î¾¹¡A¼sªx¾A¥Î©ó¤u·~À³¥Î¡C±±¨î¥\¯à¥Ñ±±¨îºâªk®w´£¨Ñ¡A±±¨îºâªk®w¥Ñ³QºÙ¬°¥\¯à¶ô(FunctionBlocks)ªº¤j¶q¹Bºâ¼ÒªO©Òºc¦¨¡Cªº¹Ï§Î¤Æªº±±¨î²ÕºA¤u¨ãControl Builder¨Ï±o±±¨îµ¦²¤ªº¥Í¦¨©M²ÕºA·¥¨ä¤è«K¡CControI Builder¤£¶È¥Î©ó²ÕºA±±¨îµ¦²¤¡AÁÙ¥i¥H±N²ÕºA¦nªº±±¨îµ¦²¤¤U¸Ë¦Ü±±¨î¾¹¨Ã¶i¦æ¦b½uºÊ±±©M¦b½u­×§ï¡C

¡´ ¥\¯à±j¤jªº±±¨î³B²z¾¹¼Ò¥ó¡A½Õ¸`©MÅÞ¿è±±¨î¤@Åé¤Æ¡A¤¾¾l°t¸m©Î«D¤¾¾l°t¸m¿ï¾Ü

¡´ 50²@¬í°ò¥»±±¨î°õ¦æÀô¹Ò

¡´ ¶°¦¨±M§QºâªkProfit Loop¡A¤ñ¶Ç²ÎPIDºâªk¡A¯à¦³®Ä´£°ª«Y²Îí©w©Ê30%¥H¤W³]­p·s¿oªº8«Y¦C¿é¤J/¿é¥X¤l«Y²Î

¡´ ²³æ¦a««ª½±µ½u¤è¦¡¡A´î¤Ö¹qÆl¸ô®|¤Î¤£¥²­nªºÅs¦±¡A´£°ª±µ½u®Ä²v¡A¨CÂI±µ½u®É¶¡¥­§¡´î¤Ö3¤ÀÄÁ

¡´ ¼Ò¶ô±Ä¥Î¡§««ª½¶É±×¦¡¡¨³]­p¡A¼W±j´²¼ö©Ê¯à¡A©ö©ó±µ½u¡A¥B¸`¬ù30%¥H¤Wªº¦w¸ËªÅ¶¡

¡´ ¤ä«ùProfibus DP³q°T¡´ ¥i¿ï¤¾¾l°t¸m¡´ ¥i¿ïHART³q°T¶°¦¨

¡´ ¥i¿ï¨¾»GÒ\¼h


¡@     DOºÝ¤lªOMC-TDOY22 51204162-175 51304337-150

·Hªùªü¦Ì±±§Þ³N¦³­­¤½¥q¾ã¦X¤F¤u·~¦Û°Ê¤Æ»â°ìªº²³¦h«~µP

¡» Invensys Triconex

¡» Westinghouse¡]¦è«Î¡^

¡» Rockwell Allen-Bradley ¡]ù§J­³º¸¡^

¡» Schneider Modicon¡]¬I­@¼w²ö­}±d¡^

¡» ABB ­¸§Q®ú ·RÀq¥Í

¡» ¥»¯S§Q3500«Y¦CºÊ´ú«Y²Î¥d/«e¸m¾¹/¶Ç·P¾¹

¡» Motorola¡]¼¯¦«Ã¹©Ô¡^

¡» XYCOM

¡» GE FANUC(GEµo¨º¬ì)

¡» Yaskawa¡]¦w¤t¡^

¡» Bosch Rexroth¡]³Õ¥@¤O¤h¼Ö¡^


§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


PCU 50.3B-C 6FC5210-0DF31-2AB0 6FC5 210-0DF31-2AB0

6FC5357-0BB33-0AE1 6FC53570BB330AE1

SIMATICC7-626/A 6ES7626-1CG01-0AE3 6ES7 626-1CG01-0AE

ZDK 2,5-2PE

S5 6ES5466-4UA11 6ES5 466-4UA11

5C2001.21 5C200121 PROVIT 2000

A06B-0243-B100 AC + A860-2000-T301

6GK5208-0BA00-2AC2 6GK5 208-0BA00-2AC2

ACS800-01-0006-3 + E200 + P901 + CDP312R

ACS800-01-0005-3 + E200 + P901 + CDP312R

6SE7090-0XX84-3EH0 6SE7090-0XX84-3EH0

8V1090.00-2 Rev. O0 + AC110 + AC120

2140350

6FC5210-0DF31-2AA0 6FC5203-0AF02-0AA1

C4MT-09014ABB03FEO 1207109

C40S-1503AA310 + C40E-1503AA310

6GK7443-1EX30-0XE0 6GK7 443-1EX30-0XE0 FS: 02

6SE7021-0TA31 6SE7090-0XX84-0AG1

IP32M 9AC9100-0AA01 9AC9 100-0AA01








Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸