·Hªùªü¦Ì±±§Þ³N¦³¤½¥q
²£«~¤¶²Ð
PlantCruise¾Þ§@¯¸(HMIWeb)
¡´ °ò©óÀN¥§³º¸ªºHMlWeb§Þ³N
¡´ ¤ä«ù¤¤¤å¬É±
¡´ ¥iµø¤è®×¹Ï¡A±±¨îµ¦²¤³]p¹Ïªº¹ê®ÉºÊµøÅã¥ÜPlantCruise³n¥ó
¡´ ºÊ±±³n¥ó´£¨Ñ°ª³t½w¦s°Ïªº¹ê®É°ÊºA¼Æ¾Ú¦s¨ú¡BÁͶաB³øĵ/¨Æ¥ó³B²z¡BºÞ²z¡B³øªí³ø§i¥Í¦¨µ¥¥\¯à
¡´ «Y²ÕºAÀô¹ÒPlantCruise²ÕºA¤u§@«Ç¥]¬A¡G
¡· ¥ø·~¼Ò«¬²ÕºA³n¥óSimplified Enterprise ModeIBuilder¡A¹ï¥ø·~¤¤ªº¸ê²£«ö¤À¯Åµ²ºcª½Æ[¦a´yz¡BÅã¥Ü
¡· ±±¨îµ¦²¤²ÕºA³n¥óControI BuiIder¡A¬°¥Í¦¨±±¨îµ¦²¤´£¨Ñ¥þ®M±±¨îºâªk®w
¡· «Y²Î¸ê·½²ÕºA³n¥óQuick Builder¡A¥Î©ó³Ð«Ø«Y²Îµw¥ó
¡· ¥Î¤áµe±²ÕºA³n¥óHMIWeb Display BuiIde¡A¥Î©ó³Ð«Ø°ò©óHTML®æ¦¡ªº¾Þ§@û¹Ï§Î¬É±
¡´ ±j¤jªº¼Æ¾Ú¥æ´«¥\¯à
¡´ ¦hºØ¨ä¥¦À³¥Î(Uniformance PHD¡BeServer¡BEBMµ¥)PlantCruiseÀ¯u±±¨î¾¹(SIM)
¡´ À¯uPlantCruise«Y²Î
¡´ °ò©óPCªºÀ¯u±±¨î¾¹Àô¹Ò¡AµL¶·±±¨î¾¹µw¥ó
²£«~¸Ô±¡¸ê®Æ
CON011«Y¦C«OÅ@µ¥¯Å¬°IP67,»P¶Ç·P¾¹³q¹LLEMO´¡ÀY³s±µ¡C
CON021«Y¦C«OÅ@µ¥¯Å¬°IP20¡A»P¶Ç·P¾¹³q¹LLEMO´¡ÀY³s±µ¡C
CON031«Y¦C«OÅ@µ¥¯Å¬°IP20,»P¥½ºÝ»r½uªº¶Ç·P¾¹³q¹LÁ³°vºÝ¤l³s±µ¡C
§Þ³N°Ñ¼Æ¡G
¿é¤J¡G´õ½ü¶Ç·P¾¹PR6422/...¡ãPR6426/...
¿é¥X¡Gª½¬y¹qÀ£¤WÅ|¥[»P¶b®¶°Ê¦¨¥¿¤ñªº¥æ¬y¹qÀ£«H¸¹¡C¦³¶}¸ô©Mµu¸ô«OÅ@¡F¦³¤Ï¦V«OÅ@¡C
¿é¥X¹qÀ£½u©Ê½d³ò¡G-4...-20V(¨Ñ¹q¹qÀ£¬°-24V¡^
¿é¥X¹qÀ£ªº¤j½d³ò¡G-1...-22V¡F
¿é¥X¹qÀ£¡G-12V¡]¨âºÝ¹ïºÙªº´ú¶q½d³ò¡^¡F
¤ºªý¡G100k
ÅTÀ³®É¶¡¡G15
ºë«×¡]©Ò¦³¼Æ¾Ú§¡¬Û¹ï©óº¡¶qµ{¡^
½u©Ê»~®t¡G
«e¸m¾¹CON0X1 CON0X1/91
³s±µ¶Ç·P¾¹PR6422¡G 1.5%
³s±µ¶Ç·P¾¹PR6423¡G 1.0% 2%
³s±µ¶Ç·P¾¹PR6424¡G 1.5% 2%
³s±µ¶Ç·P¾¹PR6425¡G 6.0%
³s±µ¶Ç·P¾¹PR6426¡G 1.5% 2%
·Åº}¡G¹sÂI200mV/100K¡FÆF±Ó«×¡Õ2%/100K¡C
®Éº}¡G¤j0.3%
¨Ñ¹q¹qÀ£ªº»~®t¡G¡Õ0.2%/V
ª`¡GCON0X1¥NªíCON011¡BCON021¡BCON031
^¤å²£«~¸Ô²Ó«H®§
The CON011 series has a protection level of IP67 and is connected to the sensor through an LEMO plug.
The CON021 series has a protection level of IP20 and is connected to the sensor through an LEMO plug.
The CON031 series has a protection level of IP20 and is connected to the sensor with bare wires at the end through screw terminals.
Technical parameters:
Input: Turbine sensor PR6422/...~ PR6426/...
Output: An AC voltage signal superimposed on the DC voltage and proportional to the shaft vibration. Equipped with open circuit and short circuit protection; There is reverse protection.
Linear range of output voltage: -4... -20V (supply voltage is -24V)
Large range of output voltage: -1... -22V;
Output voltage: -12V (symmetrical measurement range at both ends);
Internal resistance: 100k
Response time: 15
Accuracy (all data relative to full scale)
Linear error:
Proximitor CON0X1 CON0X1/91
Connect sensor PR6422: 1.5%
Connect sensor PR6423: 1.0% 2%
Connect sensor PR6424: 1.5% 2%
Connect sensor PR6425: 6.0%
Connect sensor PR6426: 1.5% 2%
Temperature drift: 200mV/100K at zero point; Sensitivity<2%/100K.
Time drift: 0.3% larger
Error of power supply voltage: ¡Õ 0.2%/V
Note: CON0X1 represents CON011, CON021, and CON031
3500«Y¦C²Õ¦¨³¡¤À·§z¡G
3500/70M©¹´_À£ÁY¾÷½ÄÀ»/³t«×ºÊ´ú¾¹
3500/72M ¬¡¶ë±ì¦ì¸mºÊ´ú¾¹
3500/77M ¨T¬ûÀ£¤OºÊ´ú¾¹
3500/63 ®ðÅéºÊ´ú¾¹
3500/92 ³q°TºôÃö
3500/93 LCD Åã¥Ü¸Ë¸m
3500/94 VGA Åã¥Ü¸Ë¸m
3500/95 «Y²Îºî¦X PC Åã¥Ü¸Ë¸m
3500/40M Proximitor? ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-®|¦V®¶°Ê¡B¶b¦V¦ì²¾¡B°¾¤ß¡B®tµÈ
3500/42M Proximitor? /¦ì²¾/³t«×¥[³t«×ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¥[³t«×¡B³t«×¡B¶b®¶°Ê
3500/45 ¦ì¸mºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¶b¦V¦ì²¾¡B®tµÈ¡B±×±®tµÈ¡B´ßµÈ¡B»Öªù¦ì¸m
§K³dÁn©ú¡G
§K³dÁn©ú¡G AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C