·Hªùªü¦Ì±±§Þ³N¦³¤½¥q
²£«~¤¶²Ð
PlantCruise¾Þ§@¯¸(HMIWeb)
¡´ °ò©óÀN¥§³º¸ªºHMlWeb§Þ³N
¡´ ¤ä«ù¤¤¤å¬É±
¡´ ¥iµø¤è®×¹Ï¡A±±¨îµ¦²¤³]p¹Ïªº¹ê®ÉºÊµøÅã¥ÜPlantCruise³n¥ó
¡´ ºÊ±±³n¥ó´£¨Ñ°ª³t½w¦s°Ïªº¹ê®É°ÊºA¼Æ¾Ú¦s¨ú¡BÁͶաB³øĵ/¨Æ¥ó³B²z¡BºÞ²z¡B³øªí³ø§i¥Í¦¨µ¥¥\¯à
¡´ «Y²ÕºAÀô¹ÒPlantCruise²ÕºA¤u§@«Ç¥]¬A¡G
¡· ¥ø·~¼Ò«¬²ÕºA³n¥óSimplified Enterprise ModeIBuilder¡A¹ï¥ø·~¤¤ªº¸ê²£«ö¤À¯Åµ²ºcª½Æ[¦a´yz¡BÅã¥Ü
¡· ±±¨îµ¦²¤²ÕºA³n¥óControI BuiIder¡A¬°¥Í¦¨±±¨îµ¦²¤´£¨Ñ¥þ®M±±¨îºâªk®w
¡· «Y²Î¸ê·½²ÕºA³n¥óQuick Builder¡A¥Î©ó³Ð«Ø«Y²Îµw¥ó
¡· ¥Î¤áµe±²ÕºA³n¥óHMIWeb Display BuiIde¡A¥Î©ó³Ð«Ø°ò©óHTML®æ¦¡ªº¾Þ§@û¹Ï§Î¬É±
¡´ ±j¤jªº¼Æ¾Ú¥æ´«¥\¯à
¡´ ¦hºØ¨ä¥¦À³¥Î(Uniformance PHD¡BeServer¡BEBMµ¥)PlantCruiseÀ¯u±±¨î¾¹(SIM)
¡´ À¯uPlantCruise«Y²Î
¡´ °ò©óPCªºÀ¯u±±¨î¾¹Àô¹Ò¡AµL¶·±±¨î¾¹µw¥ó
²£«~¸Ô±¡¸ê®Æ
3500¾÷±ñ«OÅ@«Y²ÎÄ~¹qÅéºÊµø¾¹
3500 /32M 4 ³q¹DÄ~¹q¾¹¼Ò¶ô ´£¨Ñ¥|ÓÄ~¹q¾¹¿é¥X©M°ª«×¥i°t¸mªºÄ~¹q¾¹ÅÞ¿è±µ¤f¡C¥|Ó¿é¥X¤¤ªº¨C¤@Ó³£¥i¥H¿W¥ß½sµ{¡A¥H³q¹L¬°¨CÓÄ~¹q¾¹°t¸mĵ³øÅX°ÊÅÞ¿è¨Ó±Ò¥Î§ë²¼¡C3500 ¾÷±ñ«OÅ@«Y²Î¤ºªº©Ò¦³³q¹D ³£¥i¥Î©ó¨Ï¥Î Not OK ª¬ºA¥H¤Î 3500/32M ¤ºªºÄµ³ø©M¦MÀI³]¸mÂI¨ÓÅX°Ê´_ÂøÅÞ¿è¡C3500/32M ¬°°ª«×¥i°t¸mªº AND/OR ÅÞ¿è²Õ¦X´£¨Ñ©ö©ó¨Ï¥Îªº¬É±¡A¥]¬A¡§¥¿±`¡¨©M¡§¯u¡¨©Mªí¨M¿ï¶µ¥H¤Î³¬ÂêÄ~¹q¾¹³q¹D¿ï¶µ¡C
3500/33 16 ³q¹DÄ~¹q¾¹¼Ò¶ô ´£¨Ñ 16 ÓÄ~¹q¾¹¿é¥X¡A¨ã¦³°ª«×¥i°t¸mªºÄ~¹q¾¹ÅÞ¿è±µ¤f¡C¤Q¤»Ó¿é¥X¤¤ªº¨C¤@Ó³£¥i¥H¿W¥ß½sµ{¡A¥H³q¹L¬°¨CÓÄ~¹q¾¹°t¸mĵ³øÅX°ÊÅÞ¿è¨Ó±Ò¥Î§ë²¼¡C3500 ¾÷±ñ«OÅ@«Y²Î ¤ºªº©Ò¦³³q¹D ³£¥i¥Î©ó¨Ï¥Î Not OK ª¬ºA¥H¤Î 3500/33 ¤ºªºÄµ³ø©M¦MÀI³]¸mÂI¨ÓÅX°Ê´_ÂøÅÞ¿è¡C3500/33 ¬°°ª«×¥i°t¸mªº AND/OR ÅÞ¿è²Õ¦X´£¨Ñ©ö©ó¨Ï¥Îªº¬É±¡A¥]¬A¡§¥¿±`¡¨©M¡§¯u¡¨©Mªí¨M¿ï¶µ¥H¤Î³¬ÂêÄ~¹q¾¹³q¹D¿ï¶µ¡C
^¤å²£«~¸Ô²Ó«H®§
3500 Mechanical Protection System Relay Body Monitor
The 3500/32M 4-channel relay module provides four relay outputs and highly configurable relay logic interfaces. Each of the four outputs can be independently programmed to enable voting by configuring alarm drive logic for each relay. All channels within the 3500 Mechanical Protection System can be used to drive complex logic using Not OK status and alarm and danger setpoints within the 3500/32M. The 3500/32M provides an easy-to-use interface for highly configurable AND/OR logic combinations, including "normal" and "true" and voting options, as well as blocking relay channel options.
The 3500/33 16 channel relay module provides 16 relay outputs with highly configurable relay logic interfaces. Each of the sixteen outputs can be independently programmed to enable voting by configuring alarm drive logic for each relay. All channels within the 3500 Mechanical Protection System can be used to drive complex logic using Not OK status and alarm and danger setpoints within the 3500/33. The 3500/33 provides an easy-to-use interface for highly configurable AND/OR logic combinations, including "normal" and "true" and voting options, as well as blocking relay channel options.
3500«Y¦C²Õ¦¨³¡¤À·§z¡G
3500/70M©¹´_À£ÁY¾÷½ÄÀ»/³t«×ºÊ´ú¾¹
3500/72M ¬¡¶ë±ì¦ì¸mºÊ´ú¾¹
3500/77M ¨T¬ûÀ£¤OºÊ´ú¾¹
3500/63 ®ðÅéºÊ´ú¾¹
3500/92 ³q°TºôÃö
3500/93 LCD Åã¥Ü¸Ë¸m
3500/94 VGA Åã¥Ü¸Ë¸m
3500/95 «Y²Îºî¦X PC Åã¥Ü¸Ë¸m
3500/40M Proximitor? ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-®|¦V®¶°Ê¡B¶b¦V¦ì²¾¡B°¾¤ß¡B®tµÈ
3500/42M Proximitor? /¦ì²¾/³t«×¥[³t«×ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¥[³t«×¡B³t«×¡B¶b®¶°Ê
3500/45 ¦ì¸mºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¶b¦V¦ì²¾¡B®tµÈ¡B±×±®tµÈ¡B´ßµÈ¡B»Öªù¦ì¸m
§K³dÁn©ú¡G
§K³dÁn©ú¡G AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C
SCG262A261
E67.3X63
BES M08EH-PSC40F-S49G
S5 6ES5926-3SA11 6ES5 926-3SA11
WENGLOR HK12PD
611 6SN1111-0AA01-1BA0 6SN1 111-0AA01-1BA0
S5 6ES5306-7LA11 6ES5 306-7LA11
TR ELECTRONIC HE 65M 205-00059
S5 6ES5482-7LA11 6ES5482-7LA11
L1 6ES5777-0BB00
51162267 281-607
51131667 281-607
S5 6ES5482-7LA11 6ES5 482-7LA11
S5 6ES5451-4UA13 6ES5 451-4UA13
CA 3-16 CA3-16-01
3RU1136-4EB0
AMF 6844-2
R037540000
9882-2064
E-T-A ESS20-002-DC24V 4A ESS20002DC24V4A
2016-1201 2- 20161201