·Hªùªü¦Ì±±§Þ³N¦³¤½¥q
²£«~¤¶²Ð
PlantCruise¾Þ§@¯¸(HMIWeb)
¡´ °ò©óÀN¥§³º¸ªºHMlWeb§Þ³N
¡´ ¤ä«ù¤¤¤å¬É±
¡´ ¥iµø¤è®×¹Ï¡A±±¨îµ¦²¤³]p¹Ïªº¹ê®ÉºÊµøÅã¥ÜPlantCruise³n¥ó
¡´ ºÊ±±³n¥ó´£¨Ñ°ª³t½w¦s°Ïªº¹ê®É°ÊºA¼Æ¾Ú¦s¨ú¡BÁͶաB³øĵ/¨Æ¥ó³B²z¡BºÞ²z¡B³øªí³ø§i¥Í¦¨µ¥¥\¯à
¡´ «Y²ÕºAÀô¹ÒPlantCruise²ÕºA¤u§@«Ç¥]¬A¡G
¡· ¥ø·~¼Ò«¬²ÕºA³n¥óSimplified Enterprise ModeIBuilder¡A¹ï¥ø·~¤¤ªº¸ê²£«ö¤À¯Åµ²ºcª½Æ[¦a´y¡BÅã¥Ü
¡· ±±¨îµ¦²¤²ÕºA³n¥óControI BuiIder¡A¬°¥Í¦¨±±¨îµ¦²¤´£¨Ñ¥þ®M±±¨îºâªk®w
¡· «Y²Î¸ê·½²ÕºA³n¥óQuick Builder¡A¥Î©ó³Ð«Ø«Y²Îµw¥ó
¡· ¥Î¤áµe±²ÕºA³n¥óHMIWeb Display BuiIde¡A¥Î©ó³Ð«Ø°ò©óHTML®æ¦¡ªº¾Þ§@û¹Ï§Î¬É±
¡´ ±j¤jªº¼Æ¾Ú¥æ´«¥\¯à
¡´ ¦hºØ¨ä¥¦À³¥Î(Uniformance PHD¡BeServer¡BEBMµ¥)PlantCruiseÀ¯u±±¨î¾¹(SIM)
¡´ À¯uPlantCruise«Y²Î
¡´ °ò©óPCªºÀ¯u±±¨î¾¹Àô¹Ò¡AµL¶·±±¨î¾¹µw¥ó
²£«~¸Ô±¡¸ê®Æ¡G
UFC718AE01 HIEE300936R0001
Genius I/O°t¸m½sµ{³n¥ó¥i¥H°t¸m»PGenius I/O¶ô¬ÛÃöªº°Ñ¼Æ¤l¶°¡CGenius I/O¶ô¨ã¦³³\¦h°Ñ¼Æ¡A¥i¥H¨Ï¥ÎGenius I/O¤â«ù¦¡ºÊµø¾¹¶i¦æ³]¸m¡C³o¨Ç°Ñ¼ÆȦsÀx¦b¶ô¥»¨ªºEEPROM¤¤¡C¦ê¦æÁ`½u¦a§}¡]SBA¡^©Mªi¯S²v¨Ï¥ÎGenius I/O¤â«ù¦¡ºÊµø¾¹³]¸m¡C¦³ÃöGenius I/O¶ôÃþ«¬¡B°t¸m©M³]¸mªº¨ãÅé«H®§¡A½Ð°Ñ¾\Genius I/O«Y²Î¥Î¤á¤â¥UGEK-90486-1©MGEK-90486-2¡C³q¹LCOMMREQ¥\¯à¶ô¡AÀ³¥Îµ{§Ç¥i¥H½Ð¨DGBC§ó§ï¯S©w¶ô¤Wªº¥ô¦óÀq»{±ø¥ó¡C¦ý¬O¡A¸Ó¶ô¶È¦b¤£³B©ó°t¸m«OÅ@¼Ò¦¡®É±µ¨ü¦¹§ó§ï¡CUFC718AE01 HIEE300936R0001¦pªG³]¸m¤F°t¸m«OÅ@¼Ò¦¡¡A«h¥u¯à¨Ï¥Î¤â«ù¦¡ºÊµø¾¹§ó§ïÀq»{È¡CGenius I/OªºCOMMREQ¥\¯à¶ôªº®æ¦¡¦bGFK-2017«Y¦C90-70 GeniusÁ`½u±±¨î¾¹¥Î¤á¤â¥U©MGFK-1034«Y¦C90-30 GeniusÁ`½u±±¨î¥Î¤á¤â¥U¤¤´yz¡CUFC718AE01 HIEE300936R0001
²£«~^¤å¸Ô±¡®Æ:
Genius I/O Configuration The programming software can configure a subset of the parameters associated with Genius I/O blocks. Genius I/O blocks have a number of parameters that can be set using the Genius I/O Hand-Held Monitor. These parameter values are stored in EEPROM in the block itself. The serial bus address (SBA) and baud rate must be set using the Genius I/O Hand-Held Monitor. For specific information on Genius I/O block types, configuration, and setup, refer to the Genius I/O System User¡¦s Manuals, GEK-90486-1 and GEK-90486-2. Through the COMMREQ function block, the application program can request the GBC to change any default condition on a specific block. However, the block only accepts this change if it is not in Config Protect mode. If Config Protect mode is set, only the Hand-Held Monitor can be used to change the defaults. The format of the COMMREQ function block for Genius I/O is described in the Series 90-70 Genius Bus Controller User¡¦s Manual, GFK-2017 and the Series 90-30 Genius Bus Controller User¡¦s Manual, GFK-1034.
3500«Y¦C²Õ¦¨³¡¤À·§z¡G
3500/70M©¹´_À£ÁY¾÷½ÄÀ»/³t«×ºÊ´ú¾¹
3500/72M ¬¡¶ë±ì¦ì¸mºÊ´ú¾¹
3500/77M ¨T¬ûÀ£¤OºÊ´ú¾¹
3500/63 ®ðÅéºÊ´ú¾¹
3500/92 ³q°TºôÃö
3500/93 LCD Åã¥Ü¸Ë¸m
3500/94 VGA Åã¥Ü¸Ë¸m
3500/95 «Y²Îºî¦X PC Åã¥Ü¸Ë¸m
3500/40M Proximitor? ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-®|¦V®¶°Ê¡B¶b¦V¦ì²¾¡B°¾¤ß¡B®tµÈ
3500/42M Proximitor? /¦ì²¾/³t«×¥[³t«×ºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¥[³t«×¡B³t«×¡B¶b®¶°Ê
3500/45 ¦ì¸mºÊ´ú¾¹¼Ò¶ô¡G³q¹DÃþ«¬-¶b¦V¦ì²¾¡B®tµÈ¡B±×±®tµÈ¡B´ßµÈ¡B»Öªù¦ì¸m
§K³dÁn©ú¡G
§K³dÁn©ú¡G AMIKON§Ú̾P°â·s²£«~©M°±²£²£«~¡A´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´yz¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C
GE | HE693RTD601 | GE | IC693APU300 |
GE | HE693RTD600T | GE | IC693ALG442 |
GE | HE693PBM101 | GE | IC693ALG392 |
GE | HE693ADC409 | GE | IC693ALG391 |
GE | DS3820PSCC1D1B | GE | IC693ALG223 |
GE | DS3820PSCB DS3820PSCB1C1B | GE | IC693ALG222E |
GE | DS200TCQAG1BHF | GE | IC693ALG222 |
GE | DS200TCQAG1B DS200TCQAG1BGE | GE | IC693ALG221F |