§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾TªO PR6423/105-141 CON041 3

PR6423/105-141 CON041

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

PR6423/105-141 CON041 ´õ¬y¶Ç·P¾¹EPRO


²£«~¸Ô±¡¸ê®Æ

DCS«Y²Î¬O¦p¦ó±µ¦aªº

±µ¦a¤ÀÃþ

 ¹q¤l³]³Æ¤¤¡§¦a¡¨³q±`¦³¨âºØ§t¸q¡G¡§¤j¦a¡¨©M¡§«Y²Î°ò·Ç¦a¡¨¡C

 ¡§¤j¦a¡¨¬O«ü«Y²Îªºª÷ÄÝ¥~´ß¡B½u¸ôµ¥³q¹L±µ¦a½u©Î±µ¦aªOµ¥±µ¦a¸Ë¸m»P¤j¦a¬Û³s¡A³oùØ°Q½×ªº±µ¦a§Þ³N§¡«ü±µ¤j¦a¡C

  ¡§«Y²Î°ò·Ç¦a¡¨¬O«ü«H¸¹¦^¸ôªº°ò·Ç¹q¦ì¾ÉÅé(¦p±±¨î«Y²Îªºª½¬y¹s¥ñ¾ÉÅéµ¥)¡A²ºÙ«Y²Î¦a¡C³o®É±µ¦aªº§t¸q¬O«ü³æ¤¸¡B¸Ë¸m¤º³¡¦U³¡¤À¹q¸ôªº«H¸¹ªð¦^½u»P°ò·Ç¹q¦ì¾ÉÅ餧¶¡ªº³s±µ¡A±µ¦aªº¥Øªº¬O¬°¤Fµ¹«Y²Î¦U³¡¤À´£¨Ñí©wªº°ò·Ç¹q¦ì¡C

   DCS«Y²Î¤¤¦³³\¦h»Ý­n±µ¦aªº³¡¤À¡C¥Ñ©ó¦^¸ô©Ê½è©M±µ¦a¥Øªºªº¤£¦P¡A»Ý­n¤À¦¨­Y·F¿W¥ß±µ¦a¤l«Y²Î¡AµM«á³s¦b¤@°_¹ê¦æÁ`±µ¦a¡C

A6312/06 ³t«×Áä¼Ò¶ô
A6410 Âù³q¹D¦ì¸m©M¥~´ß ®ð¬û¿±µÈºÊ´ú¼Ò¶ô
A6500-CC ³q°T¥d ¥Î©ó AMS 6500 ATG ªº°t¸m©M³q«Hªº«Y²Î¥d
A6500-RC Ä~¹q¾¹¼Ò¶ô ±a16­Ó¿é¥XÄ~¹q¾¹ªº¥i½sµ{¥d
A6500-UM ³q¥ÎºÊ´ú¼Ò¶ô ¥Î©óºÊ´ú®¶°Ê¡B¦ì²¾©M±ÛÂà
A6510 A6510-T ³B²z¾¹¥d MHMA6560¿é¤J¼Ò¶ô
A6560 ³B²z¾¹¼Ò¶ô ¨ã¦³Àþ®É¦sÀxªº¥i¯à©Ê
A6740-10 16³q¹DÄ~¹q¾¹¿é¥X¼Ò¶ô ¼Æ¦r¼Æ¾Ú³B²z
A6824 ³q°T¼Ò¶ô ModBus©M´V±µ¤f¼Ò¶ô

­^¤å²£«~¸Ô²Ó«H®§

How is the DCS system grounded

Grounding classification


In electronic devices, "ground" usually has two meanings: "ground" and "system reference ground".


'Earth' refers to the connection between the metal casing, lines, etc. of the system and the earth through grounding devices such as grounding wires or grounding plates. The grounding techniques discussed here all refer to grounding.

System reference ground "refers to the reference potential conductor of the signal circuit (such as the DC zero voltage conductor of the control system), abbreviated as system ground. At this point, the meaning of grounding refers to the connection between the signal return lines of various internal circuits of the unit and device and the reference potential conductor. The purpose of grounding is to provide a stable reference potential for various parts of the system.

There are many parts in the DCS system that require grounding. Due to the different nature of the circuit and the purpose of grounding, it is necessary to divide it into several independent grounding subsystems and then connect them together to implement overall grounding.

A6312/06 speed key module


A6410 Dual Channel Position and Shell Cylinder Expansion Monitoring Module


A6500-CC communication card is a system card used for configuration and communication of AMS 6500 ATG


A6500-RC relay module with 16 programmable cards for output relays


A6500-UM universal monitoring module for monitoring vibration, displacement, and rotation

A6510 A6510-T processor card MHMA6560 input module

A6560 processor module has the possibility of instantaneous storage

A6740-10 16 Channel Relay Output Module Digital Data Processing

A6824 communication module ModBus and frame interface module

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


¦ãÀq¥ÍKJ3222X1-BA1 12P2532X072   VE4033S2B1¦èªù¤l6ES7 153-2BA82-0XB0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X092¦èªù¤l6ES7131-4BD01-0AA0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X092   VE4003S2B2¦èªù¤l6ES7132-0BL01-0XB0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X092   VE4003S2B3¦èªù¤l6ES7195-7HF80-0XA0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X092 VE4003S2B2¦èªù¤l6ES7307-1KA00-0AA0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X092 VE4003S2B2¦èªù¤l6ES7315-1AF03-0AB0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X112   VE4003S2B2¦èªù¤l6ES7414-1XG02-0AB0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X112 VE4003S2B2¦èªù¤l6ES7417-4XL04-0AB0
¦ãÀq¥ÍKJ3222X1-BA1 12P2532X122¦èªù¤l6ES7421-1BL00-0AA0





Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H