«Y²ÎºûÅ@

¡@¡@(1)©w´Á¹ïDCS«Y²Î¹q·½¶i¦æÀˬd¡A¹ï©ó¤¾¾l¹q·½«Y²Î­n©w´Á¶i¦æ¤Á´«¹êÅç¤u§@¡C¦P®É¹ïUPS¹q·½¶i¦æ©w´Áªº¤Á´«Àˬd¡A¹ï¹q¦À«ö·Ó­n¨D¶i¦æ©w´Á©ñ¹q¥R¹q¡C

¡@¡@(2)©w´ÁÀˬdºôµ¸±µÀY©M¦U³s±µ½u¬O§_¨c©T¡A±±¨îÂd¤ºªº¦U±µ½uºÝ¤l¬O§_¨c©T¥i¾a¡C

¡@¡@(3)¸g±`Àˬd±±¨î³æ¤¸¡BI/O¼Ò¶ô¡B¨ä¥L¼Ò¶ôµ¥ªº¤u§@¬O§_¥¿±`¡C

¡@¡@(4)©w´ÁÀˬd±µ¦a¬O§_¨c©T¡A´ú¸Õ±µ¦a¹qªý¬O§_²Å¦X­n¨D¡C

¡@¡@(5)©w´ÁÀˬd±±¨î¾¹¡B­pºâ¾÷µ¥ªº¤u§@­t²ü¡A¨Ãª`·N¬O§_¦³¤É°ª²{¶H¡C

¡@¡@(6)©w´ÁÀˬdMMIµw½L¡A¨Ã§R°£¹s¸H¤å¥ó¡A¾ú¥v¤å¥ó¸g±`¶i¦æ¥~³]ÂkÀɳƥ÷¡C

¡@¡@(7)§Q¥Î¾÷²ÕÀË­×´Á¶¡³v­Ó´_¦ìDCS«Y²ÎªºDPU(¤À´²³B²z³æ¤¸)©MMMI(¤H¾÷±µ¤f)¡A¥H­pºâ¾÷ªø´Á¹B¦æªº²Ö­p¿ù»~¡C

¡@¡@(8)¹ï©óDCS«Y²Î©M¨ä¥L«Y²Î(¤ñ¦pMIS(­pºâ¾÷ºÞ²z«Y²Î)¡BSIS(¼t¯ÅºÊ±±«H®§«Y²Î)µ¥)ªº±µ¤f¡A«Øij¦b¨ä¥L«Y²Î°¼ªººôÃö¯¸¤W¡A¥[¸Ë¯f¬r¨¾¤õùÙ¡A¨Ã¤Î®É§ó·s¯f¬r®w¡C¦P®É¤Î®É§ó·s¾Þ§@«Y²Îªº¸É¤B¡A´£°ª«Y²Îªº©Ê¡C

¡@¡@(9)©w´ÁÀˬd«Y²Î­·®°¬O§_¤u§@¥¿±`¡A­·¹D¦³µLªý¶ë¡A¥H½T«O«Y²Î¯àªø´Á¥i¾a¦a¹B¦æ¡C

¡@¡@(10)¦b¾÷²Õ¤j¤p­×°±¾÷®É¡AÀ³ª`·NÀˬdDPU¥D¾÷¥dCOMS¹q¦Àªº¹q¶q¡C·í¥X²{¦]COMS¹q¦À¨S¹q¦Ó¤Þ°_COMS¼Æ¾Ú¥á¥¢ªº±¡ªp®É¡AÀ³¾ã§å§ó´«¥D¾÷ªOªºCOMS¹q¦À¡C

¡@¡@(11)©w´Á¨µÀ˲ߺD¡B©w´ÁÀˬd¡B©w´Á²M±½¡A«OÃÒDCS«Y²Î¹B¦æÀô¹Ò²M¼ä·FÐä¡C

                          ²£«~­^¤å¸Ô±¡¸ê®Æ¡G

system maintenance


(1) Regularly inspect the power supply of the DCS system, and conduct regular switching experiments for redundant power supply systems. At the same time, regular switching checks should be conducted on the UPS power supply, and the battery should be discharged and charged regularly according to requirements.


(2) Regularly check whether the network connectors and connecting wires are secure, and whether the wiring terminals inside the control cabinet are secure and reliable.


(3) Check whether the control unit, I/O module and other modules work normally.


(4) Regularly check whether the grounding is firm and test whether the grounding resistance meets the requirements.


(5) Regularly check the workload of controllers, computers, etc., and pay attention to whether there is any increase.


(6) Check the MMI hard disk regularly and delete fragmented files. Historical document are often archived and backed up by peripherals.


(7) Reset the DPU (Distributed Processing Unit) and MMI (Human Machine Interface) of the DCS system one by one during unit maintenance to eliminate accumulated errors caused by long-term computer operation.


(8) For interfaces between DCS system and other systems (such as MIS (Computer Management System) and SIS (Plant level Monitoring Information System), it is recommended to install virus firewalls on the gateway stations on the other system sides and update the virus database in a timely manner. Simultaneously update operating system patches in a timely manner to improve system security.


(9) Regularly check whether the system fan is working properly and whether the air duct is blocked to ensure long-term reliable operation of the system.


(10) When the unit is shut down for major or minor repairs, attention should be paid to checking the battery level of the DPU host card COMS. When there is a situation where COMS data is lost due to a dead COMS battery, the COMS batteries of the motherboard should be replaced in bulk.


(11) Regular inspection habits, regular inspections, and regular cleaning are necessary to ensure that the operating environment of the DCS system is clean and tidy.


§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


IC697CHS750FC-BKM-0001505-4632
IC697CMM741FC-IO-0001  IO-0001505-4732
IC697CPM790FC-IOTA-R24  51306505-175505-4832
IC697CPM915FC-QPP-0002 V1.2505-4916A
IC697CPU731FC-SAI-1620505-6108
IC697CPU772FC-SAI-1620M505-6108A
IC697CPU782FC-SDIL-1608 V1.3505-6208
IC697CPX772FC-SDO-0824 V1.3505-6660B
IC697CPX782FC-SDO-0824 V1.45136-DNS-200S
IC697CPX935-FDFC-SDOL-0424549-214
IC697HSC700FC-TSDI-1624560-2136
IC697MDL240FC-TSDI-16UNI562-001
IC697MDL250FC-TSGASH-16246AA6504-0AA






Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H
  • 01
  • §Ö³tµo¥¬¨DÁÊ«H®§
  • ¤U¤@¨B
  • 02
  • ¸Õ¸Õ¥H¤U¬ÛÃö·j¯Á¡G
  • 03
  • Áp«Ycnal«ÈªA¡G
  • ­P¹q¡G 0371-63388900
    °¨¤W±Ò°Ê±zªº§Ö³t±ÄÁʳq¹D¡I