§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T«¬§÷ DS200TCEAG1AGB¶W³tªO¼Ò¶ô 3

DS200TCEAG1AGB¶W³tªO¼Ò¶ô

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

²£«~¼ÐÃD:DS200TCEAG1AGB¶W³tªO¼Ò¶ô

«¬¸¹¡G DS200TCEAG1AGB

«~µP¡GGE

                                                                              ²£«~¸Ô±¡¸ê®Æ¡G

DO24V¥i¤ä«ù°ª¯à¶q¿é¥X¡A¥H´î¤Ö¿é¥X¦^¸ô¤¤¥~³¡²Õ¥óªº¼Æ¶q¡C***¯SÂI?***ªº¤º³¡¶EÂ_¡A¥H½T«O¼Æ¾Ú§¹¾ã©Ê?¥i¿ï¤¾¾l?ª½±µ/¤Ï¦V¿é¥X¤ä«ù?ª¬ºA¡]FAILOPT¡^¦æ¬°?¡§µL«OÀIµ·¡¨µu¸ô«OÅ@?Âê¦s¡A¯ß½Ä©Î¯ß¼e½Õ¨î¿é¥X¡]¨C­Ó³q¹D¡^?¹q¬y¹jÂ÷Á`½u24VDC DO¼Æ¦r¿é¥XÁ`½u24VDC¨ã¦³¤º³¡©M¥~³¡ÀyºÏªº³W©w¡C§@¬°¤@­ÓÁ`½u¿é¥X³]³Æ¡A©Ò¦³¿é¥X¦@¨É¤@­Ó¤½¦@¦^¸ô¡]±µ¦a¡^¡C©Ò¦³¿é¥X§¡¨Ó¦Û¦P¤@¹q·½¡A¥i¥H¬O«Y²Î¹q·½©Î¥~³¡³s±µªº24V¹q·½¡C·í¿ï¾Ü¨Ó¦Û¥~³¡¹q·½®É¡A¿é¥X¥i»PC«Y¦C¹q·½«Y²Î¹q¹jÂ÷¡C

µL«OÀIµ·µu¸ô«OÅ@¦¹***¥\¯à¤¹³\¦b¤£º²Â_¥ô¦ó«OÀIµ·ªº±¡ªp¤U¦s¦bµu¸ô¡C·í¯S©w³q¹Dµu¸ô®É¡A¤º³¡¹q¸ô·|ÀË´ú¨ì¨Ã¤ÁÂ_²{³õ³s±µªº¹q·½¡C¦bµu¸ô­×´_¤§«e¡A³q¹D«O«ùÂ_¹qª¬ºA¡CFILOPT C«Y¦CDO¼Ò¶ô±N¤ä«ù¨C­Ó³q¹DªºFAILOPT°Ñ¼Æ¡C¥i³q¹L°t¸m±N¿é¥X©w¦V¬°«O«ù***­È©Î­È¡C­È¥i¥Ñ¥Î¤á°t¸m¡C¿é¤J/¿é¥X«¬¸¹CC-PDOB01-24Volt¼Æ¦r¿é¥X¡A²{³õ¹jÂ÷¡AÁ`½u¿é¥XIOTA«¬¸¹CC-TDOB01«D¤¾¾l9¡§CC-TDOB11¤¾¾l12¡¨

                         ²£«~­^¤å¸Ô±¡¸ê®Æ¡G

The DO24V can support high energy outputs to reduce the number of external components in the output loop. Notable Features ? Extensive internal diagnostics to ensure data integrity ? Optional redundancy ? Direct/Reverse output support ? Safe-state (FAILOPT) behaviors ? ¡§Fuse-less¡¨ short circuit protection ? Latched, pulsed or pulse-width modulated output (per channel) ? Galvanic isolation Bussed 24VDC DO The Digital Output Bussed 24VDC has provisions for both internal and external field power excitation. As a bussed output device, all of the outputs share a common return (ground). All outputs get their power from the same source, which can be either the system power supply or an externally connected 24V power supply. When selection is from an external source, outputs can be galvanically isolated from the Series C power system.


Fuse-less Short Circuit Protection This unique feature allows a short circuit to exist without blowing any fuses. When a particular channel is shorted, internal circuits detect this and remove power to the field connection. The channel remains de-energized until the short circuit is repaired. FAILOPT Series C DO module will support FAILOPT parameter on a per channel basis. The output can be directed by configuration to either HOLD THE LAST VALUE, or SHED to a SAFE VALUE. The safe value can be configured by the user.Input / Output Model CC-PDOB01 - 24Volt Digital Output , Field Isolated, Bussed output IOTA Model Numbers CC-TDOB01 Non Redundant 9¡¨ CC-TDOB11 Redundant 12¡¨

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


GEIC693CHS397¥»¯S§Q330105-02-12-20-02-05
GEIC693CHS393¥»¯S§Q330105-02-12-10-02-05
GEIC693CHS392¥»¯S§Q330105-02-12-10-02-00 
GEIC693CHS391N¥»¯S§Q330105-02-12-10-02-00
GEIC693CHS391¥»¯S§Q330105-02-12-05-02-CN
GEIC693CBL305B¥»¯S§Q330105-02-12-05-02-05
GEIC693CBL300¥»¯S§Q330105-02-12-05-02-00
GEIC693BEM340¥»¯S§Q330104-00-12-10-02-00 
GEIC693BEM331¥»¯S§Q330104-00-10-10-02-00
GEIC693APU301R¥»¯S§Q330104-00-08-10-02-05  10104-00-08-10-02-05
GEIC693APU301¥»¯S§Q330104-00-08-10-02-00
GEIC693APU300J¥»¯S§Q330104-00-06-10-02-00 
GEIC693APU300¥»¯S§Q330104-00-06-10-02-00
GEIC693ALG442¥»¯S§Q330104-00-06-05-02-00












Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸