§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T«¬§÷ CV-IDNPHB DNP3¾ú¥v¼Æ¾Ú¦^¶ñ 3

CV-IDNPHB DNP3¾ú¥v¼Æ¾Ú¦^¶ñ

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

²£«~¼ÐÃD:CV-IDNPHB DNP3¾ú¥v¼Æ¾Ú¦^¶ñ 

«¬¸¹¡G CV-IDNPHB

«~µP¡GÀN¥§­³º¸

                                                                  ²£«~¸Ô±¡¸ê®Æ¡G

469±±¨î¹q·½»P¦w¸Ëªº¶}Ãö¹q·½¤Ç°t¡C¦pªG¬I¥[ªº¹qÀ£¤£¤Ç°t¡A¥i¯à·|·lÃa¸Ë¸m¡I©â¥X¦¡¸Ë¸m°¼­±ºÝ¤l¼Ðñ¤Wªº­q³æ¥N½X±N¼ÐºÙ±±¨î¹qÀ£***¬°¥H¤U¤§¤@¡G½T«O©â¥X¦¡¥~´ßºÝ¤l¼Ðñ¤W¬I¥[ªº±±¨î¹qÀ£»PÃB©w¹qÀ£¤Ç°t¡C¨Ò¦p¡AHI¹q·½¥i¦b90¦Ü300 Vªºª½¬y¹qÀ£©Î70¦Ü265 Vªº¥æ¬y¹qÀ£¤U¤u§@¡C¦pªG¬I¥[ªº¹qÀ£¶W¹L¦¹½d³ò¡A¤º³¡«OÀIµ·¥i¯à·|º²Â_¡C469¤º¸m¤F***ªºÂoªi©MÀþºA«OÅ@¡A¥H½T«O¦b´c¦Hªº¤u·~Àô¹Ò¤¤¥¿±`¤u§@¡CÀþºA¯à¶q³q¹LÂoªi¾¹±µ¦aºÝ¤l¶Ç¾É¦^¹q·½¡C¬°°ªÀ£´ú¸Õ´£¨Ñ³æ¿Wªº±µ¦aºÝ¤l¡CµL½×±±¨î¹q·½Ãþ«¬¦p¦ó¡A³s±µ©Ò¦³±µ¦a¥H¥¿±`¹B¦æ¡C

                         ²£«~­^¤å¸Ô±¡¸ê®Æ¡G

The 469 control power must match the installed switching power supply. If the applied voltage does not match, damage to the unit may occur! The order code from the terminal label on the side of the drawout unit specifies the nominal control voltage as one of the following: Ensure applied control voltage and rated voltage on drawout case terminal label match. For example, the HI power supply will work with any DC voltage from 90 to 300 V, or AC voltage from 70 to 265 V. The internal fuse may blow if the applied voltage exceeds this range.Extensive filtering and transient protection are built into the 469 to ensure proper operation in harsh industrial environments. Transient energy must be conducted back to the source through the filter ground terminal. A separate safety ground terminal is provided for hi-pot testing. All grounds MUST be hooked up for normal operation regardless of control power supply type.

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


ABBHoneywellWoodward
PM564-RP-ETHDC-TFB412 51307618-1765441-693
1SAP121000R0071
SAFT132CBS  DC-TFB402  51307616-1765464-210
3BHE028761R0102
SAFT 315F500DC-TCF901 51307593-1765466-353
SAFT315F500
TU840CC-TDOB11 51308373-1755466-355
3BSE020846R1
DO630  CC-TCNT01 51308307-175 5462-758B
3BHT300007R1
RTXP18  RTXP 18CC-TCNT01 51308307-1755461-650
RK926015-BH
AX561CC-TAOX11 51308353-175 5462-744
1TNE968902R1301
CS A465 AE01CC-TAON01 51306519-1759907-164
HIEE400109R1 








Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸