±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T«¬§÷ ±±¨î¾¹¤º¦s¤ä«ù51454475- 100 3

±±¨î¾¹¤º¦s¤ä«ù51454475- 100

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

²£«~¼ÐÃD:±±¨î¾¹¤º¦s¤ä«ù¼Ò¶ô51454475- 100

«¬¸¹¡G 51454475- 100

«~µP¡GÀN¥§­³º¸

                                                                              ²£«~¸Ô±¡¸ê®Æ¡G



°t¸mGeniusºôµ¸®É¡AÀ³¦Ò¼{¥H¤U«ü¾É­ì«h1¡CGenius§½°ìºô­­¨î¬°32»O³]³Æ¡C½Ð°O¦í¡AGeniusÁ`½u±±¨î¾¹«O¯d¤@­Ó¦a§}¡A¦pªG¨Ï¥Î¤â«ù¦¡°t¸m¾¹¡A¥¦¤]·|«O¯d¦a§}¡C2.¦pªGÀ³¥Îµ{§Ç»Ý­n¤¾¾lºôµ¸¡A«h»Ý­nÁ`½u¥æ´«¼Ò¶ô¡]IC660BSMxxx¡^¡C3.»Ý­n¦b¨C­Óºôµ¸ªº¥½ºÝ¶i¦æºÝ±µ¡]IC660BLM50x¡^4¡C¹ï©ó¶W¹L4500­^¤Øªºªø¶ZÂ÷¡A³]³Æ¼Æ¶q­­¨î¬°16­Ó¡C¥Î©ó¥»¦a±±¨îªº±±¨î¾¹¨å«¬À³¥Î°t¸m¥Ü¨Ò¡]»Ý­n¡]120¡^24 VDC¿é¤J©M¡]80¡^Ä~¹q¾¹¿é¥X¥æ¬y¹q·½ªº¥Ü¨ÒÀ³¥Î¡^¡C«Y²ÎÁÙ¦³¤­­Ó»·µ{¾÷Âd¡A¨C­Ó¾÷Âd»Ý­n¡]64¡^­Ó24 VDC¿é¤J¡B¡]21¡^­Ó24 VDC5.5 Amp¹q·½¿é¥X©M¡]2¡^­Ó¹q¬y¿é¤J©M¡]2­Ó¡^¹q¬y¿é¥X¡]24 VDC¹q·½¡^¡C±q±±¨îÂd¨ì***¤@­Ó»·µ{¾÷Âdªº¶ZÂ÷¬°3500­^¤Ø¡CVersaPoint¤À¥¬¦¡I/O«Y²Î´£¨Ñ¤Fºò´êªºÆF¬¡©Ê¡A¤¹³\¥Î¤á¦w¸Ë¨C­ÓÀ³¥Îµ{§Ç©Ò»Ýªº¾A·í¼Æ¶qªºI/O¡C¿í¦u¶}©ñ³q«H¼Ð·Ç¡A¥]¬A¥H¤Óºô¡BProfibusDP©MDeviceNet?, VersaPoint¥i»´ªQ³s±µ¨ì¦UºØPLC¡BDCS©M°ò©óPCªº±±¨î«Y²Î¡C¥¦¬O¥]¸Ë©M§÷®Æ³B²zÀ³¥Î¥H¤ÎºÊ±±©M¼Æ¾Ú±Ä¶°ªº²z·Q¿ï¾Ü¡CVersaPoint¥i®e¯Ç¤@«Y¦C±K«×±q1ÂI¨ì16ÂIªºÂ÷´²©M¼ÒÀÀI/O¼Ò¶ô¡C¥¦ÁÙ¤ä«ù³\¦h***¼Ò¶ô¡A±qRTD©M¼ö¹q°¸¿é¤J¨ì©w¦ì©M­p¼Æ¾¹¼Ò¶ô¡C


                         ²£«~­^¤å¸Ô±¡®Æ:

When configuring a Genius network the following guidelines should be considered 1. Genius LAN is limited to 32 devices. Remember that the Genius Bus Controller reserves one address and if a Hand-Held configurator is used, it also reserves an address. 2. If the application requires redundant networks, a Bus Switching Module is required (IC660BSMxxx). 3. Termination is required at the end of each network (IC660BLM50x) 4. For long distances, beyond 4,500 feet, the number of devices is limited to 16.Examples of Typical Application Configuration for Controller (Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply) for local control. System also has five remote cabinets, with each cabinet requiring (64) 24 VDC Inputs, (21) 24 VDC 0.5 Amp, Source Outputs and (2) current inputs and (2) current outputs (24 VDC power source). Maximum distance from control cabinet to the last remote cabinet is 3,500 feet.The VersaPoint Distributed I/O system provides compact flexibility and allows users to install just the right amount of I/O needed for each application. Adhering to open communications standards including Ethernet, ProfibusDP and DeviceNet?, VersaPoint connects easily to a wide variety of PLCs, DCSs and PC-based control systems. It is ideal for packaging and materials handling applications as well as for supervisory control and data acquisition. VersaPoint accommodates a series of discrete and analog I/O modules with densities from 1 to 16 points. It also supports a host of specialized modules, from RTD and Thermocouple inputs to positioning and counter modules.

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


ABBHoneywellFoxboro
3BSE000460R1 PFBO161FC-DCOM-232/485FBM202 P0926EQ
PU515 3BSE013063R1FC-BKM-0001NCNI P0972PP 
HIEE320639R1 HI024049-313 LT 8978B V1F860-CA CP60 P0961FR
HIEE400109R1 HI022755-310 CS A465 AE01DC-TFB412 51307618-176FCM10E P0914YM
086369-001DC-TFB402  51307616-176P0972VA
3HNA013638-001 SMU-03DC-TCF901 51307593-176P0904AK
CS31 FPR3315101R1032CC-TDOB11 51308373-175FBM3A/33A P0500RU
3HAC14549-3CC-TCNT01 51308307-175 FBM4/39/44 P0500RY
TC530 3BUR000101R1CC-TCNT01 51308307-175FCP270 P0917YZ








Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸