                                                                              ²£«~¸Ô±¡¸ê®Æ¡G


³q¹L¦b¤u¼t´£¨Ñ¤À¥¬¦¡±±¨î¡AGenius I/O«Y²Î´£¨Ñ¤F§ó¤Öªº²×ºÝ°O¿ý¡A¤j¤jÁYµu¤F¥¬½u®É¶¡¡A¥H¤Î§ó²³æ¡B§ó***¬G»Ù±Æ°£¡CGenius I/O¶ô¦Û°Ê´£¨Ñ¦³Ãö²{³õ±µ½u¡B¹q·½±ø¥ó©M­t¸üªº¶EÂ_«H®§¡A¥H¤Î³q«Hºôµ¸¡B¶ô©M¹q¸ôªºª¬ºA¡CGenius¶EÂ_¤j¤j´î¤Ö¤Fªì©l±±¨î©M½Õ¸Õ©Ò»Ýªº®É¶¡¡CGenius¶ô¦bCPU¡BÁ`½u±µ¤f©Îºôµ¸¹qÆl¬G»Ùªº±¡ªp¤U´£¨Ñ¥i¹w´úªº«Y²Î¾Þ§@¡C·í¦b¨â­Ó©Î¦h­ÓCPU¦P®É¹B¦æªº¤¾¾l°t¸m¤¤³s±µ®É¡A¦pªG¥D±±¨î¾¹µLªk³q«H¡AGenius¶ô±N¦Û°ÊÂಾ¨ì³Æ¥÷CPU¡CGenius¶ô³q¹LGenius LAN»P«Y²ÎCPU³q«H¡A***²¤Æ¤F«Y²Î¦w¸Ë¡A¨Ã¥B³q¹L¤â«ùºÊµø¾¹µ¥ºôµ¸¤u¨ã¡A¬G»Ù±Æ°£«Ü®e©ö¡C°£¤FGenius I/O¶ô¥~¡AVersaMax I/OÁÙ¥i¥H¶°¦¨¨ì³æ­ÓGenius LAN¤¤¡CGEK-90486D I/OÂ÷´²©M¼ÒÀÀ¶ôGEK-90486.F-1 I/O«Y²Î©M³q«HGFK-0074A Genius I/O PCIM¥Î¤á¤â¥UGFK-0415E°ª³t­p¼Æ¾¹GFK-0450D PowerTRAC GFK-0881³æ¼Ñ­Ó¤H­pºâ¾÷±µ¤f¼Ò¶ô¡]PCIM¡^GFK-1179J²Å¦X¼Ð·Çªº¦w¸Ë­n¨D


                         ²£«~­^¤å¸Ô±¡®Æ:

By providing distributed control on the factory floor, Genius I/O systems offer fewer terminations to document, dramatically shorter wiring runs, and simpler, more effective troubleshooting. Genius I/O blocks automatically provide diagnostic information on field wiring, power conditions and loads, as well as the state of the communication network, blocks and circuits. Genius diagnostics sharply reduce the time needed for initial control and debugging. Genius blocks provide predictable system operation in the event of a CPU, bus interface or network cable failure. When connected in a redundant configuration with two or more CPUs running simultaneously, the Genius blocks will shift automatically to a backup CPU if the main controller fails to communicate. Genius blocks communicate with the system CPU over the Genius LAN, greatly simplifying system installation, and with network tools such as the hand-held monitor, troubleshooting is a snap. In addition to Genius I/O blocks, VersaMax I/O may also be integrated into a single Genius LAN.GEK-90486D I/O Discrete and Analog Blocks GEK-90486F-1 I/O System and Communications GFK-0074A Genius I/O PCIM User¡¦s Manual GFK-0415E High Speed Counter GFK-0450D PowerTRAC GFK-0881 Single Slot Personal Computer Interface Module (PCIM) GFK-1179J Installation Requirements for Conformance to Standards

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


ABBHoneywellFoxboro
3BSE000460R1 PFBO161FC-DCOM-232/485FBM202 P0926EQ
PU515 3BSE013063R1FC-BKM-0001NCNI P0972PP 
HIEE320639R1 HI024049-313 LT 8978B V1F860-CA CP60 P0961FR
HIEE400109R1 HI022755-310 CS A465 AE01DC-TFB412 51307618-176FCM10E P0914YM
086369-001DC-TFB402  51307616-176P0972VA
3HNA013638-001 SMU-03DC-TCF901 51307593-176P0904AK
CS31 FPR3315101R1032CC-TDOB11 51308373-175FBM3A/33A P0500RU
3HAC14549-3CC-TCNT01 51308307-175 FBM4/39/44 P0500RY
TC530 3BUR000101R1CC-TCNT01 51308307-175FCP270 P0917YZ








Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H