§A¦n¡AÅwªï¨Ó¨ì¥@¾Tºô [½Ðµn¿ý] [§K¶Oª`¥U]
¥@¾Tºô ¾T·~²£«~
±z·í«eªº¦ì¸m¡G ¥@¾Tºô ¾T·~²£«~ ¾T«¬§÷ KJ4006X1-BP1¤j®e¶q±µ½uºÝ¤l 3

KJ4006X1-BP1¤j®e¶q±µ½uºÝ¤l

¥[¤J¦¬Âà Á|³ø
¸Ô²Ó«H®§

²£«~¼ÐÃD:KJ4006X1-BP1  Deltal v ¤j®e¶q±µ½uºÝ¤l

«¬¸¹¡G KJ4006X1-BP1

«~µP¡G¦ãÀq¥Í

                                                                ²£«~¸Ô±¡¸ê®Æ¡G


PROFIBUS PA PROFIBU for Process Automation PROFIBUS International¡]PI¡^¦¨¥ß©ó1995¦~¡A¬OPROFIBU´µªº°ê»Ú³Ê¦¡²Õ´¡C³q¹L²{³õÁ`½u³s±µ¨ì±±¨î¾¹ªº»·µ{I/O¿é¤J/¿é¥X³æ¤¸¡C¥Î©óPROFIBUS DPªºRLM 01¤¾¾lÃì¸ô¼Ò¶ô¡CRLM 01±N«D¤¾¾lPROFIBUS±q¾÷³s±µ¨ì½u¸ô¤¾¾lPROFIBUS¡CRS-485¬OEIA¡]¬ü°ê¹q¤l¤u·~¨ó·|¡^ªº³q«H±µ¤f¼Ð·Ç¡A¤u§@¹qÀ£¦b0V©M+5V¤§¶¡¡CRS-485¤ñRS-232C¨ã¦³§ó±jªº§Ü¾¸Án¯à¤O¡A¥i³B²z»·¶ZÂ÷¼Æ¾Ú¶Ç¿é¡A¨Ã¥iÅX°Ê§ó¦h±µ¦¬¾¹

PROFIBUS DP-V1ª©¥»DP-V1¥]§t­±¦V¹Lµ{¦Û°Ê¤Æªº¼W±j¥\¯à¡A¯S§O¬O¥Î©ó´¼¯à²{³õ³]³Æªº°Ñ¼Æ¤À°t¡B¾Þ§@¡B¥iµø¤Æ©M¤¤Â_±±¨îªº«D´`Àô¼Æ¾Ú³q«H¡A»P´`Àô¥Î¤á¼Æ¾Ú³q«H¨Ã¦æ¡C³o¤¹³\¨Ï¥Î¤uµ{¤u¨ã¦b½u³X°Ý¯¸ÂI¡C¦¹¥~¡ADP-V1©w¸q¤F³øĵ¡C¤£¦PÃþ«¬Äµ³øªº¥Ü¨Ò¥]¬Aª¬ºAĵ³ø¡B§ó·sĵ³ø©M¨î³y°Ó¯S©wĵ³ø¡C

                          ²£«~­^¤å¸Ô±¡¸ê®Æ¡G


PROFIBUS PA PROFIBUS for Process Automation PROFIBUS International (PI) The international umbrella organization for PROFIBUS founded in 1995. PROFIBUS User Organization e.V. (PNO) The PNO is the trade body of manufacturers and users for PROFIBUS founded in 1989. Redundancy The existence of more than one capability of an item (system, equipment or component) to perform its intended function. Remote I/O Input/Output units connected to a controller via a fieldbus. RLM 01 Redundancy Link Module for PROFIBUS DP. The RLM 01 connects a non redundant PROFIBUS slave to the line redundant PROFIBUS. RS-485 A communication interface standard from EIA (Electronics Industries Association, USA), operating on voltages between 0V and +5V. RS-485 is more noise resistant than RS-232C, handles data transmission over longer distances, and can drive more receivers

PROFIBUS DP-V1 Version DP-V1 contains enhancements geared towards process automation, in particular acyclic data communication for parameter assignment, operation, visualization and interrupt control of intelligent field devices, parallel to cyclic user data communication. This permits online access to stations using engineering tools. In addition, DP-V1 defines alarms. Examples for different types of alarms are status alarm, update alarm and a manufacturer-specific alarm.

§K³dÁn©ú¡G

AMIKON§Ú­Ì¾P°â·s²£«~©M°±²£²£«~¡A¿W¥ß´ë¹DÁʶR¦¹Ãþ¯S¦â²£«~¡Cªü¦Ì±±¤£¬O¥»ºô¯¸¯S¦â²£«~ªº±ÂÅv¤À¾P°Ó¡B¸g¾P°Ó©Î¥Nªí¡C¥»ºô¯¸¤W¨Ï¥Îªº©Ò¦³²£«~¦WºÙ/²£«~¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ð§¡¬°¨ä¦U¦Û©Ò¦³ªÌªº°]²£¡C±a¦³³o¨Ç¦WºÙ,¹Ï¤ù¡B°Ó¼Ð¡B«~µP©MÀ²¼Ðªº²£«~´y­z¡B´y¼g©Î¾P°â¶È¥Î©óÃѧO¥Øªº¡A¨Ã¤£ªí¥Ü»P¥ô¦óÅv§Q«ù¦³¤H¦³¥ô¦óÃöÁp©Î±ÂÅv¡C


IPMON01PR6423/013-030 CON0212713P-T7WD1
IPSYS01PR6423/014-121 CON031315116-A05
KSML92S1450-W-MC1 IEC60945PR6423/015-111 CON041320087-A06
LL02 LL 02PR6423/01R-111 CON031321131-A01
LZ01 LZ 01PR6423/01R-111 CON03151404127-250
LZ02 LZ 02PR6423/10R-010 CON0215370-CVIM
MA01 MA 01PR6424/000-030 CON0216155R-14S2KH
MA03 MA 03PR6424/000-040 CON0216181F-15TSXP
MA12 MA 12PR6424/000-121 CON0416181P-17TPXPH
MAG-XM 50XM2000PR6424/000-121 CON0416186M-15PT
MAI32MADPR6424/004-010 CON02174101-181-51






Áp«Y¤è¦¡
  • Áp«Y¤H¡G §d¤u ¤k¤h
  • ¹q¸Ü¡G 0592-5085207
  • ¤â¾÷¡G 18030175270
  • ¦a§}¡G ºÖ«Ø¬Ù ·Hªù¥« «ä©ú°Ï´òÀØ«n¸ô388¸¹°ê¶T¤j·H32D³æ¤¸
ÁÙ¨S§ä¨ì¦X¾Aªº²£«~¡H