HawkeÀN§J¨¾Ãz®æÄõÀY¡]Hawke cable gland¡^
Hawke 501/414 Cable Glands
Hazardous Area Flameproof Exd & Increased Safety Exe
Dual Certifi ed ATEX / IECEx
Application
Outdoor or indoor use.
For use with non-armoured elastomer and plastic insulated cables installed in conduit.
See technical section for installation rules and regulations.
Technical Data
Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21.
Certifi cate No¡¦s: baseefa06ATEX0056X and IECEx BAS 06.0013X.
Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas
Groups IIA, IIB and IIC.
Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1,
IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to
IEC/EN 60529 and NEMA 4X.
Deluge Protection to DTS01.
Operating Temperature Range: -60¢XC to +100¢XC.
Assembly Instruction Sheet: AI 310.
Alternative certifi cation options available
Features
Provides a cable retention seal onto the cables outer sheath.
When used in Increased Safety applications, this cable gland may
be used with braided cable where the braid and the cables outer
sheath pass into the enclosure. The braid must be suitably
terminated into the enclosure.
Provides female running coupler for cable gland or conduit entry.
Manufactured in Brass (standard), Nickel Plated Brass,
316 Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.
¤W®üÀ[«~¥N²z^°êHawke SB474«Y¦C±µºÞ¦¡¨¾Ãz®æÄõ
HawkeÀN§J¨¾Ãz®æÄõÀY¡]Hawke cable gland¡^
Outdoor or indoor use. Group II Hazardous Area
For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ¡¥cold flow¡¦ characteristics.
c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source.
d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source.
Example: SB474 / C / M32 / M32 / Brass / Punch Tool
Features
Provides a barrier seal between the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable.
The required number of holes for the cores are punched in the seal by means of a special tool to suit the core size.
Provides female running coupler for cable gland or conduit entry.
The SB474 cable gland is manufactured in Brass (standard), Nickel PlatedBrass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.
Exd IIC Gb, Exe IIC Gb, Extb IIIC Db
Certificate No's
baseefa06ATEX0056X and IECEx BAS 06.0013X.
Suitable for use in:
Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
Construction and Test Standards:
IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
Ingress Protection:
IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
Deluge Protection to:
DTS01
Operating Temperature Range:
-60¢XC to +80¢XC
Assembly Instruction Sheet:
AI 309.